My MAX

®

5510 power cable does not

reach the wall outlet. Can I use an

extension cord to make it reach?

Yes, but you must use only Panamax extension

cords to keep your warranty valid. Ask for

Part

# GEC1410 

(10 feet long) or 

# P12X10NEMA5-15

(Premium Grade) 

____

The provided coax or telephone jumper

cables are not long enough to reach my

equipment. Can I use other cables?

Yes, any length cable of the same type meets the

warranty requirements.

____

The 4 Amp, Isolation Transformer circuit

breaker continually trips.  What is the

problem?

The four Isolation Transformer Outlets share the

500 VA Isolation Transformer for their power

source.  The connected equipment plugged into

the four outlets is drawing more than 4 Amps

collectively, causing the circuit breaker to trip.

These four outlets are designed specifically for

low-current, digital source components.  Check

to see if you have connected a high-current

amplifier or subwoofer to the Isolation

Transformer Outlets.  If so, unplug the high-cur-

rent components and plug them into the High-

Current Outlet Bank.

____

The Isolation Transformer Outlets are not

switching ON or OFF with the MAX

®

5510.

How can I fix this?

These outlets may be set as either switched or

always-on outlets.  The 3-position, Isolated

Outlet Turn-Off Delay switch on the back panel

controls this.  Change the setting of this switch

from Always-On to a delayed setting.  This will

allow the Isolation Transformer Outlets to

become Switched Outlets.

____

The MAX

®

5510 is ON but the Voltmeter

and Ammeter are not lit up. What is the

problem?

Check the Meter Light Dimmer control to see if

the lighting is turned ON or OFF.  If the control

knob is turned OFF, turn it ON and continue

turning until you have reached the desired light

level.  If the control knob is turned ON and there

is no light, turn the knob to maximum.  If you

still have no light, call Panamax Customer

Service for help.

____

I connected the 5W Convenience Lamp

and the lamp will not work. What is the

problem?

1.

Check to see if  the  bulb is burned-out.

2.

If the bulb is good, if the unsafe voltage LED

is OFF and the light control knob is turned on

and the light is still not on, call Panamax

Customer Service for help

.

____

The halogen light on the Convenience

Lamp is dead. What type of light do I

replace it with?

The halogen light must be replaced with a

12VDC, 5-Watt bulb or damage to lamp power

supply may occur. Use USHIO JC12V-5W/BA9S

or equivalent.

____

There is an audible buzz/hum coming

from my MAX

®

5510. What is the cause

of this and how do I make it go away?

This is the result of a DC Bias that is usually

introduced in your circuit by certain appliances-

most commonly lamps with High-Low dimmer

switches and some room heaters, which use

only half of the AC sine wave. These appliances

introduce a small DC bias placed on the AC sup-

ply. Some audio equipment- especially ampli-

fiers with toroidal power transformers- may react

unfavorably to this DC voltage, and buzz. The

MAX

®

5510 isolation transformer will remove

this waveform distortion and protect the loads

plugged into the isolated outlets. If the distortion

is bad, you may actually hear the MAX

®

5510

buzzing slightly as it works to correct the AC

power. The best way to stop the buzz is to find

the source of the disturbance (most likely a

quartz lamp) and plug it into a different branch

circuit. Panamax Technical Support will be glad

to help you if you have any questions about this.

FAQs

13

INS5510 REV. B

Summary of Contents for M5510

Page 1: ...MAX 5510 ACRegenerator Owner s Manual 1690 Corporate Circle Petaluma CA 94954 www panamax com ...

Page 2: ... center that meets the power quality needs for each piece of equipment in your entertainment system This is truly a Firewall for Noise With power this clean you ll wonder how you ever used your system without it Performance alone makes this a world class product but we didn t stop there The understated elegance of the MAX 5510 s styling complements and completes even the most sophisticated Audio V...

Page 3: ...tection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Balanced vs Isolated Power 12 Frequently Asked Questions 13 TABLE OF CONTENTS USA Canada 800 472 5555 707 283 5900 Fax 707 283 5901 1 MAX 5510 ACRegenerator 1 RJ 11 Telephone Cable 3 Coax Cables for Satellite TV Cable TV and or Antennas 1 Convenience Lamp with 5W halogen ...

Page 4: ... to you Level 2 for Analog Components The second level in the Tri Power Filtration system features two banks of independently filtered outlets 2 outlets per bank for analog components These outlet banks utilize Balanced Double L filter circuits that are far superior to any other design in filtering out all forms of electromagnetic and radio frequency interference in both common and normal modes Cr...

Page 5: ...USA Canada 800 472 5555 707 283 5900 Fax 707 283 5901 3 CONNECTION DIAGRAM Tri Power Filtration System ...

Page 6: ... optimized for Cable TV or non amplified Rooftop Antenna signal line protection Telephone Jacks In Out connections for telephone line or pay per view line protection Isolation Transformer Circuit Breaker Opens in the event that equipment connected to the Isolated Outlets exceeds 4 amps current draw When white is visible the breaker has opened Reduce the load and push to reset Voltmeter Backlit ana...

Page 7: ...ear panel receptacles at the same time This will overload the lamp s power supply and cause damage not covered by the MAX 5510 s warranty 2 USE ONLY A 12V DC 5W HALOGEN BAYONET BASE ANSI T 3 REPLACEMENT BULB Use USHIO JC12V 5W BA9S or equivalent A higher rated bulb will overload the lamp power supply and cause damage not covered by the warranty 3 Make sure the protruding lamp does not interfere wi...

Page 8: ...dition This light will flash quickly when the MAX 5510 is first plugged into the wall outlet Isolated Power Green LED When this light is ON it indicates that the Isolated Power Mode has been selected for the power supply to the digital source components Balanced Power Green LED When this light is ON it indicates that the Balanced Power Mode has been selected for the power supply to the digital sou...

Page 9: ...lines between the power utility s generating plant and the wall outlet This contaminated power feeds the isolation trans former s primary winding and is regenerated through electromagnetic induction as clean power on the isolated secondary winding The outlets are connected to the secondary winding which has no conductive connection to the primary winding This isolates your digital source equipment...

Page 10: ...gged into a switched outlet on the receiver may also be used if a 12VDC trigger is not built in The MAX 5510 Voltage Sense Trigger input uses standard 3 5 mm mono mini plug jacks These jacks have electrically isolated switches built in If nothing is inserted into the input jacks the voltage sense is bypassed and the MAX 5510 Switched Outlets button on the front panel controls the startup shutdown ...

Page 11: ...V tuners operate at approximately 10 millivolts 0 01 V and utilize the frequency spec trum of 50Mhz to 950Mhz The clamping level of the MAX 5510 s cable TV protection circuitry is 700 millivolts 0 7 volts That s less than 1 volt above normal operating levels The circuitry is shielded to prevent interference and has been opti mized to have less than 1dB of signal loss throughout the entire 50Mhz to...

Page 12: ...ge threshold 95VAC the MAX 5510 will perform the following tasks until line voltage returns to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition The MAX 5510 requires line voltage to return to within the safe operating range for 10 seconds before returning to normal operating mode This is...

Page 13: ...CTION UL 1449 Surge Suppression Rating 330V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC Max Current Rating 15A 1800 Watts Thermal Fuse YES Over Under Voltage Protection YES Over voltage shutoff threshold Response time 137 4 VAC 10 milliseconds Und...

Page 14: ... field radiation from connected power cords through cur rent phase cancellation 1 Radiated electrical fields can still be evident but to a much lesser degree than with grounded neutral power unless the impedances from L G and N G in the connect ed equipment are equal With Balanced Power the asymmetric zero volt N G reference at the panel is replaced by a symmetric ground reference between line and...

Page 15: ...f the lighting is turned ON or OFF If the control knob is turned OFF turn it ON and continue turning until you have reached the desired light level If the control knob is turned ON and there is no light turn the knob to maximum If you still have no light call Panamax Customer Service for help ____ I connected the 5W Convenience Lamp and the lamp will not work What is the problem 1 Check to see if ...

Reviews: