background image

MAX

®

5500 ACRegenerator

Owner’s Manual

1690 Corporate Circle, Petaluma, CA 94954  •  www.panamax.com

Summary of Contents for M5500

Page 1: ...MAX 5500 ACRegenerator Owner s Manual 1690 Corporate Circle Petaluma CA 94954 www panamax com...

Page 2: ...at meets the power quality needs for each piece of equipment in your entertainment system This is truly a Firewall for Noise With power this clean you ll wonder how you ever used your system without i...

Page 3: ...n 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 12 TABLE OF CONTENTS 1 MAX 5500 ACRegenerator 1 RJ...

Page 4: ...the system specifically addresses the unique power requirements of current hungry components such as amplifiers and powered subwoofers These components can rapidly draw large amounts of current to rep...

Page 5: ...3 CONNECTION DIAGRAM Tri Power Filtration System USA Canada 800 472 5555 707 283 5900 www panamax com...

Page 6: ...ways On 10 and 30 seconds Satellite Coax Jacks Two pairs of gold plated F Connectors optimized for Satellite TV signal line protection Cable TV Coax Jacks Two pairs of gold plated F Connectors optimiz...

Page 7: ...to the receptacle When the knob is turned completely to the left the lamp is in its OFF state Turning the knob to the right will turn the light ON and increase the brightness In the event of an unsaf...

Page 8: ...ating that the wall outlet has a reversed line and neutral wire or there is no ground present This light will remain OFF if the wall outlet is properly wired Unsafe Voltage Red LED Under normal voltag...

Page 9: ...ed by using the isolation transformer to regenerate the AC current The power from a typical wall outlet is contaminated with electromagnetic EMI and radio frequency RFI interference noise picked up by...

Page 10: ...s jack has an electrically isolated switch built in If nothing is inserted into the input jack the voltage sense is bypassed and the MAX 5500 Switched Outlets button on the front panel has sole contro...

Page 11: ...olts to operate and utilize the frequency range of 950Mhz to 2 2Ghz The clamping level of the MAX 5500 s satellite protection circuitry is 27 volts just 3 volts above the maximum operating voltage The...

Page 12: ...owing tasks until line voltage returns to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage conditi...

Page 13: ...Circuit YES AC Line Voltage 120VAC Max Current Rating 15A 1800 Watts Thermal Fuse YES Over Under Voltage Protection YES Over voltage shutoff threshold Response time 137 4 VAC 10 milliseconds Under vol...

Page 14: ...ht turn the knob to maximum If you still have no light call Panamax Customer Service for help ____ I connected the 5W Convenience Lamp and the lamp will not work What is the problem 1 Check to see if...