BANK 1 BANK 2 BANK 3 BANK 4 BANK 5
M5400-PM
VOLTAGE REGULATOR
METER LIGHTS
METER TOGGLE
VOLTAGE
REGULATION
VOLTAGE
REGULATION
VOLTAGE
REGULATION
VOLTAGE
REGULATION
HIGH
CURRENT
WIRING
OK
VOLTS IN
VOLTS OUT
Circuit Breaker
Automatically opens
when the current load
is greater than 15
Amps. Push to reset.
Convenience LAN Port
Offers an Ethernet
pass-thru connection
between the front and
rear panel.
Power Indicators
Indicates the status of the
rear panel outlets. The LED
outlet bank icon will be lit
when the corresponding out-
lets are turned ON. They will
flash during the startup and
shutdown process.
Power Button
Press and hold for
one second to turn
Bank 3, 4, and 5 out-
lets ON or OFF.
Wiring OK LED
Normally On. Indicates
that the wall outlet is
properly grounded and
Line/Neutral polarity is
correct.
USB Charging Port
For charging portable
electronic devices
while protecting them
from unsafe voltages.
U
S
B 5V.
Display Indicator
Dimmer/Meter Mode
Pushbutton control for meter
and front panel indicator
brightness. Quick press
cycles between four bright-
ness settings. Press and hold
toggles the meter 2 display
between Volts-Out and Amps.
Gaming Outlet
Convenient front
panel switched outlet
provides voltage
regulation and surge
protection for gaming
systems, digital cam-
eras, camcorders,
and other devices.
Digital Voltmeter
Digital LED voltmeter indicates the incoming line voltage. If line
voltage drops below 90VAC, or if the line voltage exceeds 142VAC,
the display will turn off and the “unsafe voltage” indicator will flash
indicating an unsafe voltage condition.
Digital Volts Out/Ammeter
S
hows the voltage the unit is providing to connected components, when the
Meter Mode button is activated, displays actual current draw (0-15A) of the
system, giving a visual reference as to how the system is functioning under a
variety of conditions. Volts out meter will flash if the unit is out of regulation.
Note to CATV Installers:
This reminder is provided to call attention to Article 820-40 of the NEC. That article
provides specific guidelines for proper grounding. It specifies that the cable ground
shall be connected to the grounding system of the building and as close to the point
of entry as practical.
Unsafe Voltage Indicato
r
Located in the Voltmeter and
is normally off. Flashes red
to indicate that the incoming
line voltage is unsafe and the
unit has disconnected the
power to protect your equip-
ment.
M5400-PM Back Panel Connection Features
M5400-PM Front Panel Features
Panamax
1690 Corporate Circle
Petaluma, CA 94954
Phone - 707-283-5900 or 800-472-5555
Fax - 707-283-5901
Web - www.panamax.com
Customer Relations
7:30 AM – 4:30 PM, M-F
Email - [email protected]
One telephone cable
48 inches
One LAN cable (CAT-5)
48 inches
One coaxial cable, 36 inches
AC Power
Line Voltage:...................................................................120V, 60Hz
Total Current Capacity:..............................................................15 A
UL1449
S
uppression Rating:....................................................330V
Protection Modes:.......................................................L-N, L-G, N-G
Initial Clamping Level:..............................................................200V
Energy Dissipation:........................................................2125 Joules
Peak Impulse Current:.................................................72,000 Amps
Catastrophic
S
urge Circuit:..........................................................Yes
Thermal Fusing:...........................................................................Yes
Over-voltage
S
hutoff:.............................................142 VAC ± 8 VAC
Under-voltage
S
hutoff:.............................................90 VAC ± 2 VAC
EMI/RFI Noise Filtration
Banks 1, 2, 3, 4, .......................................... 80 db, 100 KHz - 2 MHz
Bank 5 High Current Outlets.........................60 db, 100 KHz - 2 MHz
Voltage Regulation (Banks 1-4)
Power / Current……………………………......……1500 VA / 12A
Input Voltage Range:……………………...………….100-136 VAC
Output Voltage Range:…………………………...120 VAC ± 6 VAC
Buck
S
tage:………....……reduces voltage in the 125-136 V range
Boost
S
tage 1:………….…boosts voltage in the 109-119 V range
Boost
S
tage 2:…………… boosts voltage in the 100-109 V range
DC Trigger Input
Jacks:............................................... 3.5mm (1/8”) mono mini-plug
Voltage and Polarity:................................. 3 - 24V DC, bidirectional
Current Requirement:............................ 4.6 mA @3V, 58 mA @24V
DC Trigger Output
Pass through.......................................................................no delay
Positive = Tip, Negative = Ring
LAN Circuits
Clamping Level:..........................................................................52V
Jacks:......................................................................................RJ-45
Wires Protected:...................................................................8-Wires
USB Circuit
Jacks......................................................................................U
S
B-A
Power Delivery...................................................... 500 mA @ 5VDC
Telephone Circuit
Fuseless/Auto-resetting:.............................................................Yes
Clamping Level:........................................................................260V
Capacitance:...............................................................30pf (approx.)
S
uppression Modes:.....................................Metallic & Longitudinal
Jacks:......................................................................................RJ-11
Wires Protected:..................................................2-Wire, Pins 4 & 5
Cable and Satellite Circuits
HD 1080 i/p Ready .....................................................................Yes
Bi-directional.............................................................................. Yes
S
hielded.......................................................................................Yes
Clamping Level...........................................................................75V
Frequency Range.....................................................0MHz - 2.2 GHz
Insertion Loss.....................................................................< 0.5 dB
Connections................................................Female “F”, Gold Plated
M5400-PM Specifications
Contacting Panamax
Contents
© 2007 Panamax, Inc. Panamax, MAX and the Panamax logo are registered U
S
trademarks of Panamax. Protect or Disconnect and
S
ignalPerfect are trademarks of Panamax, Inc.
S
IDACtor is a registered U
S
trademark of Teccor Electronics, Inc. Foreign Language Version produced by International Contact, Inc.
S
pecifications are subject to changes due to product upgrades and improvements.
MAIN POWER 120 VAC/15A
GROUND
LUG
UNIVERSAL COAX PROTECTION
1 2 3
LAN 1
LINE IN
LAN 2
LINE IN EQUIP.
PHONE
LINE IN EQUIP.
15 AMP CIRCUIT BREAKER
BANK
1 & 2
ON
BANK 5
BANK 4
BANK 2
SUB /
AMP
R
E
CEIVER
HIGH CURRENT
SWITCHED DELAYED
15A / 1800W MAX
DVD CD
PRE
AMP
DIG
IT
A
L
RADIO
HD CABLE SA
T
HD
TV / MONIT
O
R
VCR /
AUX DVR
VOLTAGE
SENSE TRIGGER
OUTPUT INPUT
BANK 3
BANK 1
VOLTAGE REGULATION
SWITCHED
12A / 1440W MAX
SWITCHED
12A / 1440W MAX
ALWAYS ON
12A / 1440W MAX
(3-24 VDC)
ALWAYS ON
12A / 1440W MAX
VOLTAGE REGULATION
VOLTAGE REGULATION
VOLTAGE REGULATION
Bank 1 and 2
Indicator Light
Normally ON, is lit
when there is power
present on the Bank 1
and 2 receptacles.
Ground Lug
Provides a common
grounding point for
equipment with sep-
arate ground leads.
Main Power
Must be plugged into a
properly wired &
grounded 3-wire outlet.
Universal TV Coaxial Jacks
3 pairs of bidirectional pro-
tection circuits optimized for
satellite, cable, and antenna
TV signal lines.
Phone Jacks
Protection circuits for standard
telephone or pay-per- view
lines. Phone circuit is auto-
resetting. Incoming phone
cord MU
S
T be plugged into
the LINE jack. Patch cords to
the equipment (satellite receiv-
er, digital video recorder, tele-
phone, etc.) MU
S
T be plugged
into the EQUIP jacks.
LAN Jacks
Protection circuits for 10/100 baseT
Ethernet lines. For the LAN 2 pro-
tected jacks, the incoming LAN line
MU
S
T be plugged into the LINE jack
and the patch cord to the equipment
MU
S
T be plugged into the EQUIP
jack. For the LAN 1 protected jacks
the incoming LAN line must be
plugged into the LINE jack and the
equipment must be plugged into the
gaming jack on the front panel. 8
wire protection, 52V clamping.
Outlet Bank 5
Two switched, high-current outlets controlled by
the front panel Power Button or the DC Trigger
input. Bank 5 has a 5 second turn on delay and
turns off immediately upon shutdown. The High
Current outlets provide power from a low imped-
ance noise filtration circuit that does not limit the
current to your equipment. Its output is noise
isolated from all other outlet banks
Outlet Banks 3 and 4
Two switched outlets with linear filtration tech-
nology (LiFT) controlled by the front panel
Power Button or the DC Trigger input. Banks 3
& 4 will turn on immediately and turn off after
a 10 second delay. LiFT EMI/RFI noise filtration
is provided by a two-stage balanced Pi filter
which also provides noise isolation from all
other outlet banks.
Outlet Banks 1 and 2
Two always-on outlets with linear filtration tech-
nology (LiFT). Power will only be turned off under
a fault condition (
S
ee specifications for over-volt-
age and under-voltage thresholds). LiFT EMI/RFI
noise filtration is provided to Banks 1 & 2 by a
two-stage balanced Pi filter which also provides
noise isolation from all other outlet banks.
2
3
Voltage Sense
Trigger Output
3.5mm (1/8”) Mini-Plug
jack. Connecting a trigger
wire to the Voltage
S
ense
Output jack will allow the
input signal to pass
through the M5400-PM to
control the startup/shut-
down of an additional
device.
Voltage Sense
Trigger Input
3.5mm (1/8”) Mini-Plug jack.
Connect to a remote trigger
device that uses a DC output to
trigger a startup/shutdown
sequence. This bypasses the
front panel power switch.
One Rack Mount Kit