Single-Phase Auto Transfer Switch / Switched PDU,
2.9kW 30A 120V, 2U Horizontal mount, 24 5-15/20R
& 1 L5-30R outlets, 2 L5-30P inputs
MODEL NUMBER:
PDUMH30ATNET
Description
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network
devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The
ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary
power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until
the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary
inputs occurs in 1-5 milliseconds. Switched PDU features include individually controllable output receptacles and
built-in network interface. Super-fast switchover between primary and secondary power sources occurs within
milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase
angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant
hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a
two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly
recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even
separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to
the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
Features
120V 30A Power Distribution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched output receptacles (agency derated to 24A continuous)
ATS features provide redundant power for critical network equipment with a single input power cord
Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface
Visual meter reports output amp and kW power consumption, plus voltage and temperature/humidity data with optional ENVIROSENSE sensor
25 switched outlets (24 5-15/20R & 1 L5-30R); 2U horizontal rackmount form factor; 11.9 in. / 30.2cm depth
Two NEMA L5-30P 10 ft. / 3m inputs connect to separate PRIMARY and SECONDARY power sources
ATS normally maintains output sourced from the primary input; As primary input power fails or becomes unstable, the ATS switches to power equipment
from the secondary input until power on the primary input is restored
Highlights
Single phase 30A 120V Auto
Transfer Switch / ATS PDU with
Solid State Switching
Enables redundant-power option
for single-corded network devices
Separate primary & secondary
inputs connect to any two
compatible power sources
2U rackmount, 2 L5-30P inputs,
25 switched outlets (24 5-15/20R,
1 L5-30R)
Individually switched outlets,
network interface and visual
current, voltage and
environmental monitoring
Applications
ATS PDU systems provide a
redundant power option with
individual outlet control for
single-corded network devices
Package Includes
PDU with attached L5-30P input
power cords
Installable 2U mounting brackets
User manuals with warranty
information