GETTING SETUP For BlueBOLT

 

BlueBOLT Online Registration

Note: 

Make sure to complete system setup #1 or # 2 before registering.

Step 1. 

Log into 

http://www.mybluebolt.com

 for online registration.

Your BlueBOLT™ enabled M4320-PRO Power Management Component is 
completely plug-and-play and does not require any software installation or 
network configuration (including configuring of network ports).
The online BlueBOLT™ control interface is operated through your web browser. 
 

Step 2.

 Using any Internet connected computer go to www.mybluebolt.com 

in your standard Internet browser. Please make sure your browser is up to date 
with the latest software for best BlueBOLT interface performance.

Step 3.

 Follow the on screen instructions to create an account and/or take 

control of your BlueBOLT™ enabled product. 

Troubleshooting

• Is your Power Management Component receiving power? Check the power 
cable and confirm the unit is on.

• Is your BlueBOLT-CV1 card installed properly? The “Link” light should be 
illuminated (solid green) and the “Activity” light should be blinking intermittently 
(green).

• Is your Internet connection functioning? Can you access a general web page?

• Is your BlueBOLT-CV1 card connected to your internet router or modem? 
Check the Ethernet cable and confirm that the unit is connected to an active 
Internet connection, and make sure those connected devices are receiving 
power.

• If you have answered “Yes” to all of these questions and are still unable to 
connect your M4320-PRO component, please contact Panamax customer 
service at 1-800-472-5555.

SYSTEM SETUP #1

 

Network Equipment Powered by M4320-PRO 
(devices in same room)

Step 1.

  Connect the power supply for the modem/router into the M4320-PRO.

Step 2.

  Connect the coaxial line or telephone DSL line from the wall, to M4320- 

 

PRO signal line pass-through protection circuits.

Step 3.

  Route coaxial cable line or telephone DSL line from the M4320-PRO  

 

back to modem/router’s input.

 

Step 4.

  Plug in and switch on M4320-PRO.

SYSTEM SETUP #2 

Network Equipment NOT-Powered by M4320-PRO 
(devices in separate rooms)

Step 1.

  Connect network Ethernet cable from PoE/network adapter or wall    

 

plate to the Ethernet pass-through protection port on M4320-PRO.

  

 

Step 2.

  Connect second Ethernet cable from pass-through protection port to   

 

BlueBOLT-CV1 card.

Step 3.

  Power on M4320-PRO. (Note: adding a device to your home/office    

 

network may require a power cycle of the router/modem to 

 

establish connection.

Once you input the 

MAC ADDRESS

 and included 

CHALLENGE KEY

, if 

BlueBOLT™ cannot detect your device (please allow up to 60 seconds), 
please follow the on-screen troubleshooting guide. Also confirm an 
Internet connection by accessing a general website – 
example www.panamax.com.

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

MODEM / ROUTER

COAX       LAN     TEL

BlueBOLT

AC

AC

ETHERNET 

CABLE

COAX CABLE

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

BlueBOLT

AC

ETHERNET 

CABLE IN

FROM WALL

Advanced Operation

Besides providing access to Panamax/Furman’s hosted BlueBOLT platform, 
the included BlueBOLT-CV1 card also supports the following networking 
protocols:
 

• Telnet (default port 23), for interfacing to control and 

 

    automation systems within the local network.

 

• HTTP (web server at default port 80) for configuring the 

 

   network settings for stand-alone “static IP” operation.

For more information, see the application note BlueBOLT Advanced Net-
working, available online at www.mybluebolt.com.

Note:

 You will need the BlueBOLT-CV1’s unique 

MAC ADDRESS

 and 

CHALLENGE

KEY

 (duplicate labels provided in packaging on cover of Quick Start Guide as well 

as on the card itself) in order to register the BlueBOLT™ device online.

Summary of Contents for M4320-PRO

Page 1: ...kHz 46 db 250 kHz 1 MHz One Isolated Filter Bank for High Current Devices 60db 5 kHz 450 kHz 46 db 450 kHz 1 MHz Front Panel Circuit Breaker Integrated Front Rack Ears 12 Volt Input Triggering Detacha...

Page 2: ...RIGHTNESS OUTLET STATUS REBOOT 1 REBOOT 2 M4320 PRO B LT Blue ENABLED VOLTS RS232 Table of Contents Feature Descriptions pg 1 Important Safety Instructions Front Panel Features Overview pg 2 Preset Pr...

Page 3: ...time This can cause speaker thumps which are not only annoy ing but can also damage the speakers and or trip product circuit breakers The M4320 PRO is designed to eliminate these transients by provid...

Page 4: ...te a full power up or shut down sequence The front panel outlet is always on unless the circuit breaker is set to OFF VOLTS AMPS BRIGHTNESS Ro tate knob for front panel brightness control and press to...

Page 5: ...off BREAKER or holding both REBOOT buttons A V EXTENDED DELAYS OUTLET SEQUENCING profile P3 by outlet s Start up 1 10 sec 2 10 sec 3 10 sec 4 10 sec 5 10 sec 6 10 sec 7 20 sec 8 Shut down 8 20 sec 7 2...

Page 6: ...75V clamping HD 1080i p ready 0 5 dB 0 Hz 2 2 GHz 5 LAN Cat 5e 10 100 1000BASE T compatible RJ 45 8P8C Ethernet protection pass through 6 Telco RJ 11 6P2C analog telephone DSL protection pass through...

Page 7: ...e or telephone DSL line from the M4320 PRO back to modem router s input Step 4 Plug in and switch on M4320 PRO SYSTEM SETUP 2 Network Equipment NOT Powered by M4320 PRO devices in separate rooms Step...

Page 8: ...________________________________________ __________________________________________ __________________________________________ __________________________________________ ______________________________...

Page 9: ...s list before proceeding The BlueBOLT CV1 should already be factory installed in this Panamax M4320 PRO component To switch from BlueBOLT functionality to RS 232 connectivity follow these steps 1 Unpl...

Page 10: ...4 ALL ON Turns on all outlets Turn on is immediate with no delay 3 4 1 Command ALL_ON CR 3 4 2 Action All outlet relays turn ON Terminates any running turn on or turn off sequence Overrides the DC tri...

Page 11: ...FOR 6 20 11 DELAY FOR 7 21 6 DELAY FOR 8 26 1 3 7 SET REBOOT DELAY Assign the delay between the last outlet turning off and the beginning of the turn on se quence in a reboot cycle 3 7 1 Command SET_R...

Page 12: ...e PROFILE n SELECTED CR 4 QUERIES 4 0 IDENTIFY Request that the unit identify itself 4 0 1 Query ID CR 4 0 2 Response PANAMAX CR MAX 4315 PRO CR FIRMWARE revision CR 4 1 FAULT STATUS Request the on of...

Page 13: ...R status CR 5 7 3 Condition When a wire fault is detected a message will be sent to indicate the status of the indicator 5 7 4 Message WIRE FAULT status CR 5 7 5 Condition When the temperature exceeds...

Page 14: ...number and a description of the problem Contacting Customer Service 2010 Panamax LLC 1690 Corporate Circle Petaluma CA 94954 www panamax com 707 283 5900 Fax 707 283 5901 INS00860 REV D 5 17 10 12 M43...

Reviews: