background image

The Bubble of Protection

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

Rear Panel Features Overview

1.  Power inlet:

 M4320-PRO (120 Vac/20 A, IEC 320 C20 do not remove steel 

retention clip. (20A plug)  

2.  Ground  lug:

  connect  to  Panamax  MOD-series  signal  protection  module 

grounding busses with 14 AWG (<12” length) wire to expand signal protection 
capabilities.

3. Outlets:

 all rear panel outlets are separately controlled. They are grouped 

into four (4) filter-isolated banks.

 

BANKS 1-3:

  

Filtered Outlets (Outlets 1, 2, 3, 4, 5, 6)

 

 

76dB (5 kHz – 250 kHz),  46dB (250 kHz - 1 MHz)

                            

                         

        _____________________________________________
       

BANK 4: 

High-Current Outlets 

(Outlets 7-8, 20A) 

       

60dB (5 kHz – 450 kHz),  46dB (450 kHz - 1 MHz)

4. CATV/SAT 1 & 2:

 Universal voltage (±75V clamping), HD 1080i/p ready, 

<0.5 dB @ 0 Hz - 2.2 GHz. 

5. LAN Cat 5e 

(10/100/1000BASE-T compatible): RJ-45 (8P8C) Ethernet 

protection pass-through.

6. Telco:

 RJ-11 (6P2C) analog 

telephone/DSL protection pass-
through. Do not connect in reverse 

OUT 

Connects to Equipment

IN

 - 

Comes in from the wall

7. DC Trigger Input: 

3.5mm mono jack, ± (5-24 VDC) tip ring.

8. TCP/IP card (BlueBOLT) installed

9. Communications Card: RS-232 

(female DB-9) included, not shown.

1.

2.

4.

5.

8.

7.

6.

4

Sample setup to indicate the basic configuration for a “Bubble of Protection”.

9.

OUT          IN

BANK 4                   BANK 3                   BANK 2                  BANK 1     

B r aker

P anel

M4315-PRO

MIW XT with Pass 

Through Plugs. No 

protection modules are 

needed since the TV’s 

power is plugging into 

the Panamax component 

product.

Video Device

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

MODEM / ROUTER

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

M4315-PRO

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

BlueBOLT-CV1

IN

O

U

T

TV

A/V RECEIVER

MODEM / ROUTER

M4320-PRO

TV

BUBBLE O

F PR

OTE

CTIO

N

NETWORK SWITCH

SAT

SAT

CAT 5e

TEL/DSL

DVD / BLU-RAY

A / V RECEIVER

MEDIA SERVER / EXTENDER

DVR

SUB

MIW-XT OUTLET

MIW-XT INLET

AC
COAX
CAT 5e
SIGNAL
SPEAKER

Outlets 8 and 7 - 20A

Summary of Contents for M4320-PRO

Page 1: ...kHz 46 db 250 kHz 1 MHz One Isolated Filter Bank for High Current Devices 60db 5 kHz 450 kHz 46 db 450 kHz 1 MHz Front Panel Circuit Breaker Integrated Front Rack Ears 12 Volt Input Triggering Detacha...

Page 2: ...RIGHTNESS OUTLET STATUS REBOOT 1 REBOOT 2 M4320 PRO B LT Blue ENABLED VOLTS RS232 Table of Contents Feature Descriptions pg 1 Important Safety Instructions Front Panel Features Overview pg 2 Preset Pr...

Page 3: ...time This can cause speaker thumps which are not only annoy ing but can also damage the speakers and or trip product circuit breakers The M4320 PRO is designed to eliminate these transients by provid...

Page 4: ...te a full power up or shut down sequence The front panel outlet is always on unless the circuit breaker is set to OFF VOLTS AMPS BRIGHTNESS Ro tate knob for front panel brightness control and press to...

Page 5: ...off BREAKER or holding both REBOOT buttons A V EXTENDED DELAYS OUTLET SEQUENCING profile P3 by outlet s Start up 1 10 sec 2 10 sec 3 10 sec 4 10 sec 5 10 sec 6 10 sec 7 20 sec 8 Shut down 8 20 sec 7 2...

Page 6: ...75V clamping HD 1080i p ready 0 5 dB 0 Hz 2 2 GHz 5 LAN Cat 5e 10 100 1000BASE T compatible RJ 45 8P8C Ethernet protection pass through 6 Telco RJ 11 6P2C analog telephone DSL protection pass through...

Page 7: ...e or telephone DSL line from the M4320 PRO back to modem router s input Step 4 Plug in and switch on M4320 PRO SYSTEM SETUP 2 Network Equipment NOT Powered by M4320 PRO devices in separate rooms Step...

Page 8: ...________________________________________ __________________________________________ __________________________________________ __________________________________________ ______________________________...

Page 9: ...s list before proceeding The BlueBOLT CV1 should already be factory installed in this Panamax M4320 PRO component To switch from BlueBOLT functionality to RS 232 connectivity follow these steps 1 Unpl...

Page 10: ...4 ALL ON Turns on all outlets Turn on is immediate with no delay 3 4 1 Command ALL_ON CR 3 4 2 Action All outlet relays turn ON Terminates any running turn on or turn off sequence Overrides the DC tri...

Page 11: ...FOR 6 20 11 DELAY FOR 7 21 6 DELAY FOR 8 26 1 3 7 SET REBOOT DELAY Assign the delay between the last outlet turning off and the beginning of the turn on se quence in a reboot cycle 3 7 1 Command SET_R...

Page 12: ...e PROFILE n SELECTED CR 4 QUERIES 4 0 IDENTIFY Request that the unit identify itself 4 0 1 Query ID CR 4 0 2 Response PANAMAX CR MAX 4315 PRO CR FIRMWARE revision CR 4 1 FAULT STATUS Request the on of...

Page 13: ...R status CR 5 7 3 Condition When a wire fault is detected a message will be sent to indicate the status of the indicator 5 7 4 Message WIRE FAULT status CR 5 7 5 Condition When the temperature exceeds...

Page 14: ...number and a description of the problem Contacting Customer Service 2010 Panamax LLC 1690 Corporate Circle Petaluma CA 94954 www panamax com 707 283 5900 Fax 707 283 5901 INS00860 REV D 5 17 10 12 M43...

Reviews: