Summary of Contents for Kapture KP1-D7

Page 1: ...time to power up 4 Battery change 4 Access the lock via the keypad code 5 Lock Unlock UI 5 Privacy Mode 5 Low Battery Level 6 Keypad Programming Commands 6 Reset the lock 7 Key Cover Open 7 Lock Out 8 Volume Control 8 Auto Lock 8 Lock Error 8 Kapture Cloud Account Registration Sign Up 9 Log in the Kapture App 9 Paring the app to the lock via the Bluetooth Adding A Lock 9 Lock Settings in Kapture A...

Page 2: ...er Installation Guide Operation Modes The Kapture lock can function on one of the three modes mentioned below Keypad Programming Mode In this mode a smartphone is needless when operating a Kapture lock After the hardware installation setting the lock and adding the user s keypad code via the keypad Stand Alone Mode Bluetooth Only In this mode you need to download a Kapture app and register an acco...

Page 3: ...k and hides the cylinder If it stays open within a period of time the alert will activate And master s Kapture app will receive the alert under Link Mode There is an LED on the exterior lock that tells all the access UI whether success or failure Both exterior and the interior lock have a buzzer that tells all the access UI whether success or failure The lock is power saving and normally remains t...

Page 4: ...k setting you have to pair the lock with the Kapture app via Bluetooth in advance Users can access the door via physical key keypad code or the Kapture app The owner can manage the user right through the app and manage it anywhere you want for real time control Up to 100 Family or Guests can be invited through Owner or Family via the app to access the lock Users Owner Family Guest can set their ow...

Page 5: ...thout any registration via a unique keypad code which is granted remotely from the other users Equipped with real time alerts The real time alerts can be set by Owner and families on their own app to be notified of the interested lock status The owner and Family can remote access the lock Provide any of the status changes to the lock and real time events all in the record Update the Link through O...

Page 6: ...rect keypad code makes the lock open accompanied by beeps and Led flashes in red three times In Stand Alone Mode An audit trail remains Access via the keypad codes is able to check the person who is however you need to ensure a code belongs to the specific person Guest s keypad code is unique therefore you can tell the person for sure In Link Mode An audit trail remains Access via the keypad codes...

Page 7: ... cancel the Privacy Mode via the app Stand Alone Mode and LINK Mode The settings of the Privacy Mose will be in the record Low Battery Level 10 battery level goes to Low battery level The interior Led flashes every 5 seconds till to run out of the power Highly suggest replacing four new batteries to the lock If the replacement still below 10 power level the Led will keep flashing In Stand Alone Mo...

Page 8: ...eep x 2 Reset the lock After a long press on the reset button for 5 seconds with a long beep the lock will do the latch position recognition and end up the lockbolt extend If reset success the lock returns to factory default and enters the Keypad Programming Mode If the reset fails please reset it again Please note that the Bluetooth will be turned on with a successful reset however it will be tur...

Page 9: ...stages are recorded in the audit trail In Link Mode All the lockout stages are recorded in the audit trail A real time alert will be sent to the Owner s and Family s app in every lockout stage Volume Control There are three stages of volume control Mute is available Default is the medium Use the Keypad Command to set the volume when In Keypad Programming Mode Stand Alone Mode and LINK Mode Make su...

Page 10: ... code length should be 8 10 digits with uppercase lowercase and at least one number 0 9 You may receive the confirmation email to the email address you registered The confirmation code in the email has 6 digits and the registration success when entering it to the app If you fail to receive the confirmation email please check the junk mail first Besides you may resend the confirmation email as well...

Page 11: ... stages and mute Lock out Keypad disabled off on Auto lock off on delay 10 99 seconds Please note that Guest can only set the volume Lock information on the Kapture app Serial No Firmware Version Model No Battery Level change by time To change the settings needs the app to connect with the lock through the Bluetooth All the settings keeps in the audit trail User Roles Different account has a diffe...

Page 12: ...ions The owner can manage the user right to a lock after lock pairing and all the settings will keep in Kapture Cloud The inviter can set an account for a user role by inviting and an account can be invited once The email ID is needed as an invitee The invitee can be invited via the email to receive an invitation mail or a mobile phone number to receive an SMS Inviter can invite or cancel permissi...

Page 13: ...its keypad code will generate right away and Guest will receive it through an SMS or the invitation email The invitee will receive instruction in the invitation email for the Kapture App download and account registration In LINK Mode the invitee can access the door via the keypad code without carrying the smartphone and the app To generate remove permissions keeps in the audit trail The first time...

Page 14: ...ng changed to setting value by email fullname 14 Lock added to email fullname at datetime 15 Lock battery low at datetime 16 Lock battery changed at datetime 17 Audit trail started at datetime after battery changed 18 Lock jam at datetime 19 Lock cover open at datetime 20 Auto lock at datetime 21 Firmware upgrade start at datetime 22 Firmware upgrade fail at datetime 23 Firmware upgrade success at...

Page 15: ...on the power on with the Led flashing once in green The led lights in red before the pairing Long press the Kapture button for 5 seconds makes the LINK return to factory default The Led flashes in red rapidly The Led flashes in green rapidly when finding the Wifi AP The Led flashes in red slowly when the LINK is connected to the Wifi AP but the lock The Led flashes in green slowly Success pairing ...

Page 16: ...y by App at datetime by email fullname 6 Family Specific lockName unlocked remotely by App at datetime by email fullname 7 Family Guest Specific lockName invitation accepted by email name 8 Security Alerts Lock lockName battery low at datetime 9 Security Alerts Lock lockName reset at datetime 10 Security Alerts Lock lockName jam at datetime 11 Lock Action Lock lockName cover open at datetime 12 Se...

Page 17: ...this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different...

Page 18: ...ement 低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用者均不得擅自變 更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通 信或工業 科學及醫療用電波輻射性電機設備之干擾 17 ...