background image

  

12 Operating 

Your 

AT2KD 

1-800-773-7931    WWW.PALSTAR.COM 

Before Operating 

1. To avoid possible damage to the AT2KD set TUNE, IN-

DUCTOR, and POWER RANGE switches as outlined in 
the chart before applying transmitter power. 

2. Begin tuning with your transmitter/amp into the tuner set 

at a low output power setting (50-100 Watts). 

Tuning

 

1. Select the band and frequency of desired operation. 

2. Set TUNE and INDUCTOR controls to the suggested 

setting before applying transmitter power (see chart). Ac-

WARNING: DO NOT OPERATE THE AT2KD  
 

 WITH THE COVER OFF. 

TUNE INDUCTOR 

SUGGESTED ACTUAL SUGGESTED ACTUAL 

160 M 

50-52  

56(SW IN) 

 

80 M 

50-52   136  

60 M 

50-52   177  

40 M 

50-52   201  

20 M 

50-52   232  

17 M 

50-52   236  

15 M 

50-52   236  

12 M 

50-52   236  

10 M 

50-52   236 

MAX 249 

BAND 

Note:  The AT2KD must be supplied with 12VDC to 

operate the relay in order to use it on the160 Meter 

band. 

1-800-773-7931    WWW.PALSTAR.COM 

                              Front Panel Description   9 

the back panel must be supplied with 12 VDC for this to 
function. 

6. INDUCTOR 

18 µH continuously variable ceramic roller 

inductor driven by a crank handle coupled to a gear-
driven precision mechanical counter. 

7. 160 METER SWITCH 

Pushing this button to the IN po-

sition switches in extra inductance for the 160 Meter 
Band. The button should be in the OUT position for use 
on all other bands — 80 through 6 Meters. 

8. TUNE 

Continuously adjustable differential capacitor. 

9. DIRECT/TUNED MODE SWITCH 

Six-position rotary 

switch selects intended RF output coaxial connector and 
direct mode (which bypasses the tuning network) and 
tuned position (which routes RF through the tuning net-
work). 

     

a. DIRECT BYPASS 

selects BYPASS COAX connec-

tor, bypassing the impedance matching circuit but pro-
viding SWR, FORWARD and REFLECTED meter read-
ings. 

     

b. DIRECT COAX 1 

selects COAX 1 connector, by-

passing the impedance matching network but providing 
SWR, FORWARD and REFLECTED meter readings. 

     

c. DIRECT COAX 2 

selects COAX 2 connector, bypass-

ing the impedance matching network but providing 
SWR, FORWARD and REFLECTED meter readings. 

     d. TUNED COAX 1 

selects COAX 1 connector through 

the impedance matching T network. 

     e. TUNED COAX 2 

selects COAX 2 connector through 

the impedance matching T network. 

     f. COAX-BAL-WIRE 

selects the COAX-BAL-WIRE 

output connector and routes RF through the impedance 
matching T network. 

Summary of Contents for AT2KD

Page 1: ...ey Rd Piqua OH 45356 USA Customer Service and Sales Telephone 1 800 773 7931 Fax 1 937 773 8003 Email info palstar com Version 1 0 2010 01 15 Copyright 2010 Palstar Inc Printed in the U S A AT2KD 2000...

Page 2: ...ization this product is equipped with a 3 wire line cord receptacle It is intended for use with a 3 wire properly grounded power socket Do not defeat the safety purpose of the supplied line cord and p...

Page 3: ...ng the operating instructions Adjust only those controls that are covered by the operating instructions An improper adjust ment may result in damage and will often require extensive work by a qualifie...

Page 4: ...s been designed and manufactured to high quality standards and will provide reliable operation for many years Please carefully read the Owner s Manual in order to take advantage of the many interest i...

Page 5: ...rnal Balun Dimensions 5 75 H x 13 2 W x 12 D incl terminals Weight 12 lbs Materials Chassis and top cover is 11 ga 090 aluminum that has been chem film treated in gold color Front Panel powder coated...

Page 6: ...of one 1 year from the date of delivery to the first buyer the Warranty Period Palstar Inc s obligation under this war ranty is limited to repair or replacement of the product at its option at the Pal...

Page 7: ...hs clean the roller coil with 70 isopropyl alcohol and a clean cotton cloth Do not trans fer any of the conducting grease on the rod that guides the roller wheel as this will contaminate the windings...

Page 8: ...tion select that position 4 If you use a linear amplifier set it to Standby Do not use the linear amplifier until the AT2KD is tuned Do not ex ceed 1500 Watts average single tone 5 Set RANGE switch to...

Page 9: ...y a crank handle coupled to a gear driven precision mechanical counter 7 160 METER SWITCH Pushing this button to the IN po sition switches in extra inductance for the 160 Meter Band The button should...

Page 10: ...D DIFF T TUNER Directional Coupler Peak Peak Hold PCB Cross Needle SWR Power Meter 8 12 Fixe Induc AT2KD Schematic 11 1 800 773 7931 WWW PALSTAR COM Optional Balun 1 1 or 4 1 B2KD 1 1 B2KD 4 1 160M 80...