background image

EN

1. CAUTIONS

1.1 

This appliance can be used by children aged from 8 years and above and persons with 
reduced physical, sensory or mental capabilities or lack of experience and knowledge if they 
have been given supervision or instruction concerning use of the appliance in a safe way and 
understand the hazards involved. Children shall not play with the appliance. Cleaning and 
user maintenance shall not be made by children without supervision.

1.2 WARNING: 

In order to avoid overheating, do not cover the heater.

1.3  

Children of less than 3 years should be kept away unless continuously supervised.

 

1.4  

Children aged from 3 years and less than 8 years shall only switch on/off the appliance 
provided that it has been placed or installed in its intended normal operating position and 
they have been given supervision or instruction concerning use of the appliance in a safe 
way and understand the hazards involved.Children aged from 3 years and less than 8 years 
shall not plug in, regulate and clean the appliance or perform user maintenance.

1.5   CAUTION - 

some parts of this product can become very hot and cause burns. Particular 

attention has to be given where children and vulnerable people are present.

2. INTRODUCTION

2.1 

  Depending on the power cord type this fan heater may be used only in household, 

warehouses and workshops, building sites or greenhouses depending. It incorporates 
a thermostat and a self-resetting thermal cut-out to control the heating elements. The 
thermostat feels the air temperature and controls the surrounding temperature.The fan 
motor is controlled by thermostat and it keeps on working when the thermostat cuts off the 
heating element. The self-resetting thermal cut-out will switch off the heater to ensure the 
safety when overheating. 

2.2

   When using the heater for the first time, you may notice a slight emission of smoke. This is 

quite normal and it stops after a short time. The heating element is made of stainless steel 
and was coated with protection oil by production. The smoke is caused by the left oil when 
heated.

4. DESCRIPTION OF CONTROL PANEL

Heater off

Fan only

1500 Watt

4.1       Left Knob: 

selector with heat setting.

4.1.1    

For ventilation only - activate fan mode. For Heating - activate heating mode.

4.2      Right Knob: 

Thermostat dial.

You can use the appliance in:

 household, warehouses and workshops,  

building sites or greenhouses 

3. PREPERATION

Model

GP 08 15

Voltage

110V~120V~

Required power

1500W

Current

12.5-13.64A

Required Fuse

15A

Setting

40/1500W

Self-resetting Thermostat

75°C

Product meas (mm)

295x262x363

N.W.(KG)

4.7

3.1  

Housing of steel plate and coated by heat-resistant powder.

3.2  

Supplied complete with cord and plug. 

1500W PORTABLE SPLASH RESISTANT GREENHOUSE FAN HEATER  

Summary of Contents for GP 08 15

Page 1: ...d these instructions carefully before starting assembly Keep these instructions in a safe place for future reference IMPORTANT Suitable for all Palram Canopia Greenhouses IPX4 SPLASH PROOF STANDARD 40...

Page 2: ...ou to a form that will help us assist you as soon as possible SCAN ME Contact us on our website bit ly 3js7yZi 2 ASSEMBLY ASSISTANCE If you need any technical assistance in assembling your product go...

Page 3: ...91 094 04 848 6816 customer serviceDE palram com customer serviceFR palram com info il palram co il ITALY NETHERLANDS PORTUGAL SPAIN AUSTRIA LUXEMBURG LIECHTENSTEIN AUSTRALIA 33 169 791 094 49 180 522...

Page 4: ...om CZECH REPUBLIC FINLAND POLAND 0493 523 523 Neuvonta 09 6866720 Tuki Varaosat 050 3715350 Infolinia 801 011 929 22 349 93 36 servis garland cz www horisontenterprises fi tuki horisontenterprises fi...

Page 5: ...this fan heater may be used only in household warehouses and workshops building sites or greenhouses depending It incorporates a thermostat and a self resetting thermal cut out to control the heating...

Page 6: ...pliances as unsorted municipal waste use separate collection facilities Contact you local government for information regarding the collection systems available If electrical appliance are disposed of...

Page 7: ...urtain plastic bag paper and other things which can cover the inlet or can be easily cover on the air inlet The appliance didn t heat up or only ventilator worked The switch was not put at heating set...

Page 8: ...iers Il inclut un thermostat et un interrupteur thermique avec r initialisation automatique pour le contr ler des l ments chauffants Le thermostat d tecte la temp rature de l air et contr le la temp r...

Page 9: ...s lectriques avec les d chets m nagers non tri s utiliser des installations de collecte s par es Contacter votre gouvernement local pour obtenir des informations sur les syst mes de collecte disponibl...

Page 10: ...rticles tels que les rideaux les sacs en plastique le papier etc qui peuvent couvrir l entr e d air L appareil ne s est pas chauff ou seul le ventilateur s est mis en marche L interrupteur n a pas t r...

Page 11: ...ch Netzkabeltyp darf dieser Heizl fter nur in Haushalten Lagerhallen und Werkst tten Baustellen oder Gew chsh usern verwendet werden Es beinhaltet einen Thermostat und einen selbstr ckstellenden Therm...

Page 12: ...befindet 5 2 16 Elektroger te nicht als unsortierten Hausm ll entsorgen sondern getrennte Sammelstellen nutzen Wenn Elektroger te auf Deponien oder Deponien entsorgt werden k nnen gef hrliche Stoffe...

Page 13: ...anderen Gegenst nden die leicht den Lufteinlass abdecken k nnen Das Ger t heizte nicht auf oder nur das Beatmungsger t funktionierte Der Schalter wurde nicht auf Heizungseinstellung gestellt Schalten...

Page 14: ...strucci n o invernaderos Este dispositivo incorpora un termostato y un interruptor t rmico de auto reinicio para controlar los elementos de calefacci n El termostato percibe la temperatura del aire y...

Page 15: ...instalaciones y contenedores para la recolecci n diferenciada P ngase en contacto con su gobierno local para obtener informaci n sobre los sistemas de recolecci n disponibles Si los aparatos el ctrico...

Page 16: ...otras cosas que puedan tapar la entrada o que puedan envolverse f cilmente sobre la entrada de aire El aparato no se calent o solo funcion el ventilador El interruptor no fue puesto en la configuraci...

Reviews: