Wipe ends with

alcohol pads

Male End

Female End

Snap Ring

Outer Vent
1” Overlap

Install Self-
Tapping Screws

Before starting the vent installation,
careful planning should be given to the
routing and termination of the vent and
air intake pipe see Figure on page 11
and 12.  The vent system requires
mechanical support from the wall,
sufficient to support any incidental
loads on the system. If the wall is not
sufficient enough to support the vent
system, then appropriate additional
framing and/or blocking is required
and appropriate fasteners must be used
to secure the faceplate to the support
members.

Notice:  The location must comply
with national and local codes

.

Make a 7-1/4 inches (18.42 cm)
diameter hole at the determined vent
terminal location.  Make the hole from
inside the room.  The opening inside
the room should be slightly higher than
the outside opening, approximately 2
degrees, so the flue pipe will slope
slightly downward after it is installed.
A minimum pitch of at least ¼” per
foot downward slope must be made
towards the termination.  This will
enable condensate to drain from the
flue to the outside and prevent rain and
snow from entering from outside, after
installation.

Remove any insulation from the
opening and add any additional
framing if required.

Joining the vent parts

-

Before joining the sections or fittings
together, use an alcohol pad or cloth to
wipe the joint area of both ends of the
inner pipe. This will remove any
foreign matter.  Install the system with
the female ends (ends with the red
seal) pointing away from the
appliance.  Insert the male end of the
air intake/vent termination piece into
the female end of the 4”/7” concentric
vent pipe (See Figure on left). In
extremely dry conditions it may be
helpful to moisten the seal with clean
water prior to assembly.

Push firmly on the male end until the
outer jacket has made contact with the
snap ring located in the female end of
the 4”/7” concentric vent pipe section.

When fully assembled, the outer
female end (see Figure to left) will
overlap the male end by approximately
1 inch (25.4 mm).

Use the self-tapping screws provided
with the vent kit to connect the two
outer pipes (See Figure on left.).

Position the faceplate into the prepared
hole from the outside.

Measure the thickness of the wall.
The 4”/7” concentric vent pipe
supplied with the vent kit, is designed
for a maximum wall thickness of 8”
(20 cm).  If the wall thickness is
greater than 8” (20 cm), an extension
piece or longer length of pipe is
required.

Slide the male end 4”/7” concentric
vent pipe thru the faceplate from
outside the room until it comes to a
stop at the bead. Approximately 8 3/8
inches (20 cm) of the vent terminal
should stick outside the wall.

Ensure the orientation of the air intake
piece is such that the label on the 4
inch (10 cm) vent pipe is on top and
the drain hole on the 7 inch (17.8 cm)
air intake pipe is at the bottom.  After
proper orientation of the vent terminal
and the air intake pipe alignment.  The
slots and holes on the termination will
be at the bottom to allow condensation
to escape. See Figure on left.
Slide the second faceplate from the
inside the room on to the 4”/7”
concentric vent pipe till it comes to a
stop on the inner wall of the room.

Ensure that the termination (vent pipe)
is sloped downward towards the
termination.

Secure interior faceplate to outer vent
pipe and inner wall using appropriate
fasteners.

Secure the assembly into the prepared
opening using fasteners as indicated by
sheathing or structural members,
sealing the screw heads with more
caulking.

Alignment

Slots and holes

WARNING: Use UL

approved Category III vent
material only. No other
vent material is permitted.

CAUTION: Follow the

vent manufacturers
installation instructions as
design might vary from
manufacturer to
manufacturer.

The water heater must be installed with an UL approved Category III Stainless Steel appliance vent
adapter and Paloma approved vent termination.

7” Pipe

4” Pipe

Horizontal Vent Installation

13

Summary of Contents for Tankless Water Heater

Page 1: ...er heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includes a parts list It is very impor...

Page 2: ...ers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty You can also registe...

Page 3: ...ER INSTALLAND PROPERLY VENT THE WATER HEATER Gasoline as well as other flammable materials and liquids adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT...

Page 4: ...switch adjustment Only qualified service personnel should perform this adjustment Only factory authorized remote control s should be used Notice When this water heater is supplying general purpose hot...

Page 5: ...P gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level l Before attempting to light the water heater make sure to loo...

Page 6: ...ormation in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage personal injury or loss of life FOR INSTALLATIONS IN THE STATE OF CALIFO...

Page 7: ...l The water heater should be installed as close as practical to the vent termination to minimize vent length and the number of elbows required for venting l The water heater should be installed with...

Page 8: ...y other appliance To do so may result in an explosion or fire WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Imm...

Page 9: ...they must be corrected in accordance with the venting instructions in this manual before completing the installation and putting the water heater into service DANGER Failure to install the appliance...

Page 10: ...hould have a downward slope towards the vent termination The vent should have a 1 4 per foot DOWNWARD slope towards the vent terminal as shown above If the air intake pipe or duct is connected to the...

Page 11: ...t 91 cm J Clearance to nonmechanical air supply inlet to the combustion air inlet to any building or other appliance 6 inches 15 cm for appliances 10 000 Btuh 3 kW 12 inches 30 cm for appliances 10 00...

Page 12: ...ate can freeze on the exterior wall under the eaves and on surrounding objects Some discoloration to the exterior of the building is to be expected However improper location or installation can result...

Page 13: ...ocated in the female end of the 4 7 concentric vent pipe section When fully assembled the outer female end see Figure to left will overlap the male end by approximately 1 inch 25 4 mm Use the self tap...

Page 14: ...ale end of the air intake connection of the air intake tee Install the appliance adapter onto the appliance outlet and inlet and clamp as required Now attach other required vent and air intake materia...

Page 15: ...5 m If required use silicone sealant at the point the vent connector joins the water heater Chase Requires 6 15 cm Clearance to Combustibles Firestop Firestop Tall Cone Flashing Vent Adapter 3 8 cm C...

Page 16: ...carried out by a qualified plumber in accordance with local codes Use approved plumbing materials only The diameter of the pipe lines should be a minimum of 3 4 To conserve energy and to prevent free...

Page 17: ...e water inlet and the hot water outlet as shown on the water heater If reversed the water heater will not function Installation of unions or flexible copper connections are recommended on the HOT and...

Page 18: ...be installed in the discharge line Notice Local codes govern the installation of relief valves If local codes require that a temperature and pressure relief valve should be installed the manufacturer...

Page 19: ...e gas supply line which does not exceed the maximum supply pressure DO NOT use an industrial type gas regulator High Altitude Gas Supply The supplied Manual Gas Appliance Shutoff Valve must be install...

Page 20: ...with this water heater DO NOT attempt to disassemble the remote control WARNING Field wiring connections and electrical grounding must comply with local codes or in the absence of local codes with th...

Page 21: ...able from the water heater l l Place the remote control over the base plate Ensure the projections in the base plate fit into the housings in the remote control l l Fix the control to the base plate a...

Page 22: ...lt interrupter l An ON OFF switch must be provided and installed for the incoming 120VAC power l Wire the water heater exactly as shown below A wiring Figure is also found inside of the cover panel l...

Page 23: ...valve See NFGC B149 for complete instructions Local codes or plumbing authority requirements may vary from the instructions or figures provided and take precedent over these instructions Vacuum Relief...

Page 24: ...s Inlet Check Valve Inlet Pipe Cold Water Hot Water Insulate all the way to the top Insulation Blankets Insulation blankets available to the general public for external use on gas water heaters are no...

Page 25: ...ion and sediment trap q Approved pipe joint compound used q Soap and water solution used to check all connections and fittings for possible gas leak q Gas Company inspected installation if required D...

Page 26: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Page 27: ...g valves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed plumber or the local plumbing authority for further information...

Page 28: ...that hotter water increases the risk of scald injury Always supervise young children or others who are incapacitated The water heater is equipped with a device that will shut off the gas supply to th...

Page 29: ...pection maintenance and or cleaning ensure proper operation by turning on a hot water faucet Housekeeping Before performing Housekeeping tasks to this water heater turn the unit off and disconnect the...

Page 30: ...cleaning a vacuum cleaner can be used on the burner Proper burner pattern Care and cleaning of the water heater Vacation and Extended Shut Down If the water heater is to remain idle for an extended p...

Page 31: ...breaker at least 10 seconds after step 1 Open all hot water faucets Before proceeding to the next step make sure that COLD water is coming out of all hot water faucets Close the water shut off valve...

Page 32: ...pplied and or water supply is adequate Unit is not ON l Turn the unit ON by the button The temperature may be set too low Mixing Valve Malfunctions if applicable l Check and replace if necessary Error...

Page 33: ...evices Refer repairs to qualified service personnel CAUTION Make certain power to water heater is OFF before removing protective cover FOR ANY REASON CAUTION Label all wires prior to disconnection whe...

Page 34: ...nt Water Heater Instructions For Placing a Parts Order Address parts orders to the distributor or store from where the water heater was purchased All parts orders should include The model and serial n...

Page 35: ...setting to 120 49 C Follow first four bullets points listed above then continue as listed below l Press the Min button on the left hand side of the PCB for more than 1 second The LED on the PCB starts...

Page 36: ...omplete satisfaction you should then contact the following address 2151 Eastman Avenue Oxnard CA 93030 Phone 805 278 5499 When contacting the manufacturer the following information will be requested a...

Page 37: ...line without the use of a temperature sensor timer or a continuously operating pump All Applicable Warranty Periods will be limited to one 1 year from the Effective Date if the water heater is instal...

Page 38: ...ter heater or component part s Paloma will not reimburse any party for these or any other fees not specifically covered in this Limited Warranty document HOW TO OBTAIN WARRANTY CLAIM ASSISTANCE Any cl...

Page 39: ...Paloma Industries Inc 2151 Eastman Avenue Oxnard CA 93030 PRINTED IN JAPAN 31 51901 00...

Reviews: