i) Damages, malfunctions, or failures caused by operating the unit at water temperatures exceeding the maximum setting of
    the operating, or high limit control.
j) Heat Exchanger failures caused by operating the water heater when it is not supplied with potable water at all times.
k) Damages, malfunctions, or failures caused by subjecting the heat exchanger to pressures, or fi ring rates, greater than 
    those shown on the rating label.
l) Damages, malfunctions, or failures resulting from the use of any attachment, including any energy saving device, not
    authorized by Paloma.
m) Units installed outside the fi fty states (and the District of Columbia) of the United Sates of America and the Dominion 
    of Canada.
n) Units removed from the original installation location and reinstalled elsewhere.
o) Units that have had their rating labels altered, tampered with, or removed. A water heater should not be operated if the
    rating label is removed.
p) This water heater if it is installed for use in: spa or pool heating; a mobile home; a recreational vehicle; a boat or any
    other watercraft.
q) Units installed in any circulating system in which the temperature set point of the water heater is in excess of 120ºF for
    residential models and 140ºF for commercial models.

LABOR, SHIPPING, AND PROCESSING COSTS

For one (1) year after the Effective Date, Paloma will cover reasonable labor costs necessary to repair or replace a tankless 
water heater or component part it determines to be defective in material and/or manufacture by a contractor which is li-
censed, state qualifi ed, and trained for Paloma’s tankless water heater. Except for the above one (1) year labor, this Limited 
Warranty does 

not

 cover any 

labor expenses

 for service, repairs, reinstallation, permits, or removal and disposed of the 

failed water heater, or defective component part(s). All such expenses are your responsibility.
Paloma will pay the 

transportation costs

 for an “In-warranty” replacement water heater, or “In-warranty” replacement 

component part(s), to a convenient delivery point (selected by Paloma) near the place where the original water heater, 
or original component part(s), is located: such as a local Paloma water heater distributor. You must pay any local freight 
charges, including the cost of returning the failed water heater, or defective component part(s) to a convenient shipping 
location (selected by Paloma); such as a local Paloma distributor.
Paloma does 

not

 authorized, recommend, or receive any benefi t from any 

claims processing or similar fees

 charged by 

others to process warranty claims for any Paloma water heater or component part(s). Paloma will 

not

 reimburse any party 

for these, or any other, fees not specifi cally covered in this Limited Warranty document.

HOW TO OBTAIN WARRANTY CLAIM ASSISTANCE

Any claim for warranty assistance must be made promptly. First, determine if your water heater is “In-Warranty” (that is, 
within the Applicable Warranty Period). You can determine your unit’s warranty status by adding its Applicable Warranty 
Period to its date of purchase. However, if you do not have documentary proof of your water heater’s date of purchase, 
your unit’s warranty status will be based on its date of manufacture. The fi rst four digits of the unit’s serial number rep-
resent the month and year it was manufactured. Add the Applicable Warranty Period plus ninety (90) days to the date of 
manufacture to determine whether the water heater is still covered by this Limited Warranty. You may also determine your 
unit’s warranty status by obtaining the complete model number, complete serial number, and date of purchase of your water 
heater and then contacting Paloma at (805) 278-5480 during normal business hours (in the Pacifi c Time Zone) to determine 
if the Applicable Warranty Period has expired.
If your water heater is “In-warranty”, contact the plumber, or mechanical contractor, that installed it for assistance with the 
warranty repairs, or replacement, required. Paloma/Rheem Water Heaters’ 

Technical Service personnel are available to 

assist you (by telephone at (800) 432-8373 or via e-mail at [email protected])

 in obtaining “In-warranty” service 

or to answer your questions about the operation or repair of your water heater during normal business hours (in the Central 
Time Zone). Be prepared to provide the plumber, mechanical contractor, or Paloma/Rheem Technical Service person you 
call with the complete model number, the complete serial number, and the date of purchase of your water heater in addition 
to an explanation of your water heater problem.
If an exact replacement is not available, Paloma will provide you with the current model of your water heater, or compo-
nent part(s), or a replacement unit with comparable operating features. If government regulations or industry certifi cation 
or similar standards require the replacement water heater, or replacement component part(s), to have features not found in 
the defective water heater, or the defective component part(s), you will be charged for the difference in price represented 
by those required features. If you pay the price difference for these required features and/or to upgrade the size and/or other 
features available on a replacement new water heater, you will also receive a complete new Limited Warranty (with the full 
Applicable Warranty Periods) for the replacement new water heater.

38

Summary of Contents for PH2-20R DVSN

Page 1: ...wo to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includes a parts list It is very important that all p...

Page 2: ...y over the life of your water heater You ll find many answers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may not need to call for service...

Page 3: ...terials and liquids which include but are not limited to adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammabl...

Page 4: ...achieved with the Bath USC 117 or USC2 117 remote control Only qualified service personnel should perform this adjustment Only factory authorized remote control s should be used Notice When this water...

Page 5: ...e or LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to...

Page 6: ...ntial water heaters of a capacity greater than 52 gallons or tankless style consult the local building jurisdiction code for acceptable bracing procedures Have the installer show you the location of t...

Page 7: ...be installed as close as practical to the vent termination to minimize vent length and the number of elbows required for venting The water heater should be installed with the proper venting materials...

Page 8: ...horized by the gas supplier or fire department Improper installation adjustment alteration service or maintenance can cause property damage personal injury or death Refer to this manual Installation a...

Page 9: ...liance vent adapter and properly vent the water heater to the outdoors as outlined in the Venting section of this manual will result in unsafe operation of the water heater causing death serious injur...

Page 10: ...n hose to the drain fitting and plumb the hose to a sanitary sewer drain See Examples A and B on pages 13 and 14 for DOWNWARD and UPWARD slope for horizontally vented water heaters When a water heater...

Page 11: ...or other appliance 6 inches 15 cm for appliances 10 000 Btuh 3 kW 12 inches 30 cm for appliances 10 000 Btuh 3kW and 100 000 Btuh 30kW 36 inches 91 cm for appliances 100 000 Btuh 30kW 6 inches 15 cm...

Page 12: ...ainst accidental contact with people and pets Indoor Water Heater 12 WARNING Moisture in the flue gas will condense as it leaves the vent terminal In cold weather this condensate can freeze on the ext...

Page 13: ...nd center mark this location If the heater is below the vent exit remove it from the wall and place it in a safe area while the vent opening is made Create a 6 diameter hole to allow the vent to pass...

Page 14: ...rance to Combustibles Firestop Firestop Support Plate Adjustable Roof Flashing Concentric Vent Pipe has 0 Clearance Requirment Storm Collar Support Clamp 1 4 per foot upward slope on horizontal run Ve...

Page 15: ...should be followed Operation of the water heater requires the minimum water pressure of 14 psi 97 kPa and a minimum water flow rate of 0 66 gpm 2 5 lpm A water pressure of 40 psi 276 kPa is required t...

Page 16: ...heck Valve between the water heater and the water shutoff valve if either a thermal expansion tank or a backflow prevention device is not installed The following should be addressed in regards to the...

Page 17: ...be installed in the discharge line Notice Local codes govern the installation of relief valves If local codes require that a temperature and pressure relief valve should be installed the manufacturer...

Page 18: ...d at the bottom of the gas line Do not use excessive force over 31 5 ft lbs 42 7 Nm in tightening the pipe particularly if teflon pipe compound is used as the unit may be damaged The inlet gas pressur...

Page 19: ...Field wiring connections and electrical grounding must comply with local codes or in the absence of local codes with the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada Canadi...

Page 20: ...ote control over the base plate Ensure the projections in the base plate fit into the housings in the remote control Fix the control to the base plate at the bottom of the remote control using the scr...

Page 21: ...T JAUNE G Y GREEN YELLOW AC 120V O ORANGE ORANGE CODE DE COULEUR COLOR CODE MIN BUTTON BOUTON MIN G YorG W BOUTON MAX BL BL BL LED G G MAX BUTTON ADJUSTER BUTTON BL BOUTON DE R GLAGE BL 1 2 3 4 5 A FO...

Page 22: ...Line Shut off V alve Union Cap Condensate Drain Line to Suitable Drain NOTICE The National Fuel Gas Code NFGC and B149 mandates a manual gas shut off valve See NFGC B149 for complete instructions Loca...

Page 23: ...storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover any damage or defect caused by installation attachment...

Page 24: ...rating plate Gas supply pressure is sufficient for the water heater Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and water solution used to che...

Page 25: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Page 26: ...s to the water heater If there is any difficulty in understanding or following the Operating Instructions or the Care and Cleaning section it is recommended that a qualified person or serviceman perfo...

Page 27: ...member that hotter water increases the risk of scald injury Always supervise young children or others who are incapacitated The water heater is equipped with a device that will shut off the gas supply...

Page 28: ...the hot water heater discharges periodically this may be due to a problem in the water system Contact the water supplier or your plumbing contractor on how to correct this DO NOT plug the relief valve...

Page 29: ...the left for location of sight glass If any unusual burner operation is noted the water heater should be shut off until qualified service assistance can be obtained CAUTION For your safety burner ins...

Page 30: ...s can occur from down draft of venting system or from installation in areas exposed to cold air The water heater is equipped with a Freeze Protection Electric Heater As long as electricity is supplied...

Page 31: ...Valve Malfunctions if applicable Check and replace if necessary Error code displayed on remote control See instructions for Error Code and if required contact a dealer for service Not enough water de...

Page 32: ...r safety devices Refer repairs to qualified service personnel CAUTION Make certain power to water heater is OFF before removing protective cover FOR ANY REASON CAUTION Label all wires prior to disconn...

Page 33: ...ical wiring gas piping burners vent connectors or other safety devices Refer repairs to qualified service personnel WARNING For your safety DO NOT attempt to disassemble this unit for any reason Front...

Page 34: ...38 C or 85 F 29 C Press and hold the Down button on the remote control for more than 5 seconds Number on the display of the remote control will begin to blink While the number is blinking push the Do...

Page 35: ...ay not function properly NOTICE If the water heater is installed less than 3 280 feet 1 000m no action is required How to adjust the DIP switch on the PCB for high altitude installation Check the alti...

Page 36: ...ttic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requirements of this subdivision can not be met at...

Page 37: ...line without the use of a temperature sensor timer or a continuously operating pump All Applicable Warranty Periods will be limited to one 1 year from the Effective Date if the water heater is instal...

Page 38: ...ter heater or component part s Paloma will not reimburse any party for these or any other fees not specifically covered in this Limited Warranty document HOW TO OBTAIN WARRANTY CLAIM ASSISTANCE Any cl...

Page 39: ...ich the defective part was removed or the date of purchase of the part If it was purchased separately to establish the In warranty status of the defective component part If Paloma determines that the...

Page 40: ...Paloma Industries Inc 2151 Eastman Avenue Oxnard CA 93030 PRINTED IN USA PII 1109...

Reviews: