TEMPERATURE CONTROL – DELUXE
31
Bath Fill Mode – Explanatory Notes
To operate the Bath Fill mode:
1.
Turn off all Deluxe controllers
It is advised to turn off all Deluxe controller(s) before
activating the Bath Fill mode.
Refer to the notes on the
Bathroom Deluxe
controllers
on page 27.
The Deluxe controllers do not need to be on to set
the bath fill temperature and bath fill water volume
and to turn on the Bath Fill mode.
2.
Pull down the front panel on the Deluxe controller.
The BATH
FILL VOLUME and BATH
FILL
TEMPERATURE up (
) and down (
) buttons will be
exposed.
3.
Set the bath fill temperature
Press the BATH
FILL TEMPERATURE
(
up
button) or the BATH FILL TEMPERATURE
(
down
button).
The first press of either the BATH
FILL
TEMPERATURE
(
up
button) or the BATH FILL
TEMPERATURE
(
down
button) will bring up the
last selected bath fill temperature setting.
While the bath fill temperature is displayed, each
subsequent press of the BATH
FILL
TEMPERATURE
(
up
button)
or
BATH FILL
TEMPERATURE
(
down
button) will change the
temperature setting.
Refer to
“Temperature Adjustment – Deluxe
Controllers”
on page 24.
When the BATH
FILL TEMPERATURE
(
up
button) is pressed and the temperature
setting is increased, the voice prompt will sound;
“hot water temperature has been increased”
When the BATH FILL TEMPERATURE
(
down
button) is pressed and the temperature setting is
decreased, the voice prompt will sound;
“hot water temperature has been decreased”
The selected temperature setting will be displayed in the temperature display panel and will be
displayed on all Deluxe controllers.
The temperature display panel will go blank 3 seconds after the last press of either of the bath fill
temperature adjustment buttons.
The bath fill temperature setting will be remembered when the BATH FILL button is pressed “on”.
Rheem
BATH
(
l
)
4 0
°C
1 2 0
ACTIVE
ON/OFF
BATH
FILL
B1
BATH
FILL
VOLUME
BATH
FILL
TEMPERATURE
ACTIVE
Light
on
2.
Adjust
Temperature
3.
Open
hot
tap
4.
Hot
Water
Press
1.
ON/OFF
Bath
Water
Volume
Bath
Fill
Temp
Bath
Fill
Set
Bath
Fill
Water
Volume
and
Temperature
1.
2.
Bath
Fill
completed
(automatic)
Bath
Fill
Button
(Red
light
flashes)
6.
Close
hot
tap
5.
Press
Bath
Fill
Button
(Red
light
on)
3.
4.
Open
hot
tap
BATH
FILL
Press
Bath
Fill
Button
(R
ed
light
off)
7.
BATH
FILL
Rheem
BATH
(
l
)
4 0
°C
1 2 0
ACTIVE
ON/OFF
BATH
FILL
B1
BATH
FILL
VOLUME
BATH
FILL
TEMPERATURE
ACTIVE
Light
on
2.
Adjust
Temperature
3.
Open
hot
tap
4.
Hot
Water
Press
1.
ON/OFF
Bath
Water
Volume
Bath
Fill
Temp
Bath
Fill
Set
Bath
Fill
Water
Volume
and
Temperature
1.
2.
Bath
Fill
completed
(automatic)
Bath
Fill
Button
(Red
light
flashes)
6.
Close
hot
tap
5.
Press
Bath
Fill
Button
(Red
light
on)
3.
4.
Open
hot
tap
BATH
FILL
Press
Bath
Fill
Button
(R
ed
light
off)
7.
BATH
FILL
“hot water
temperature
has been
increased”
or
“hot water
temperature
has been
decreased”