background image

12

CALDERA E CORTEN FIRE PIT | Owner and Installation Manual

CLEANING AND MAINTENANCE

WARNING: Turn off gas before servicing fire pit. It is recommended that 

a qualified service technician perform these check-ups at the beginning 

of each fire pit season.

If any irregularities are apparent with operation. Please refer to Troubleshooting 

guide, pages 11-12.

BURNER ELEMENT AND PILOT

Keep the burner and pilot area clean by vacuuming or brushing at least twice a year. 

Make sure the burner porting and burner air openings are free of obstructions at all 

times. 

Inspect area around the burner. Remove any lint or foreign material with a brush or 

vacuum cleaner.

If it evident that the burner is damaged, the burner must be replaced prior to the 

appliance being put into operation.

PILOT FLAME

The flames from the pilot should be 

visually checked as soon as the unit 

is installed, and periodically during 

normal operation.  The pilot flame 

must always be present when the 

fireplace is in operation or connected 

to the gas line with the main shutoff 

valve open and the IPS activated 

(powered).  The pilot flame has two 

distinct flames:  one engulfing the 

flame sensor, and the other reaching 

to the main burner.

Burner Element

Pilot Assembly

Summary of Contents for caldera CIF-E-18

Page 1: ...WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyllinder not connected for use shall not be stored in the vicinity of t...

Page 2: ...3 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appl...

Page 3: ...e See Fig 1 Please make sure that the gas line is located only within this area This will ensure that the final position of the unit will not be compromised ATTENTION Gas line must be installed by a l...

Page 4: ...pit from damage Carefully tilt and lift fire pit so that it is resting on its side Make sure that the fire pit is secure and supported before proceeding 7 Connect flex hose to Natural Gas or Propane...

Page 5: ...G 2 Caldera Corten Top and Underside COMPONENTS 1 Burner Assembly 3 Gas Electrical Connection NOTE Weather protection is recommended for power adapter Locate gas and power supply stubs at the outer mo...

Page 6: ...6 CALDERA E CORTEN FIRE PIT Owner and Installation Manual FIG 3 MINIMUM CLEARANCES TO COMBUSTIBLES CLEARANCE TO COMBUSTIBLES 72 72 15 17 CALDERA BOL...

Page 7: ...ng if necessary Always completely extinguish burner and pilot and wait for media to cool before making adjustments 6 Do not cover pilot shield Keep the lighting port open and free of media Do not use...

Page 8: ...en flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures i...

Page 9: ...T Btu Hr INLET PRESSURE MIN INLET PRESSURE MAX MANIFOLD PRESSURE ORIFICE SIZE BURNER PORTS PORT SIZE CIF E 18 69 000 4 5 W C 10 5 W C 3 5 W C 18 68 1 8 CIF E 18P 60 000 11 0 W C 13 0 W C 10 0 W C 37 6...

Page 10: ...ed service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or mainte...

Page 11: ...n the supply gas control valve to the ON position 7 Plug the supplied AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing 1...

Page 12: ...nings are free of obstructions at all times Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner If it evident that the burner is damaged the burner must b...

Page 13: ...local natural gas company 2 Separate the stones to allow more flame passage 3 Remove any foreign items from the flame pattern and or check for proper orifice sizing Burner is excessively noisy Note Th...

Page 14: ...loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 9 or replace pilot assembly 4 Check reconnect le...

Page 15: ...LUSTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 750 mA CHASSIS GROUND PILOT NA410...

Page 16: ...n CIF 18 Venturi Orifice Control Box c w Cover Chassis Flex Connector Power Adapter 24 VAC 750 mA not shown 1 1 1 1 1 1 1 2 1 RBP018 PAN025 FLAT25 VNA017 O33018 CBCIR CHACIR FC6812 AC24 750 RBP018 PAN...

Page 17: ...17 CALDERA E CORTEN FIRE PIT Owner and Installation Manual 10 12 13 11 9 15 16 3 4 ILLUSTRATED PARTS LIST...

Page 18: ...Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembl...

Page 19: ...19 CALDERA E CORTEN FIRE PIT Owner and Installation Manual NOTES...