 Specifications • 

23

Interface Specifications

Interface Specifications

Table 9 describes the interfaces for the PA-3000 Series firewalls.

Electrical Specifications

Table 10 lists the electrical specifications for the PA-3000 Series firewalls.

Table 9.   PA-3000 Series Interface Specifications

Specification

Description

Ethernet ports

PA-3020/PA-3050—Twelve RJ-45 10/100/1000 ports for network 
traffic.

PA-3060—Eight RJ-45 10/100/1000 ports for network traffic.

Small Form-Factor Pluggable 
(SFP) ports

PA-3020/PA-3050—Eight SFP ports for network traffic.

PA-3060—Eight SFP and 2 SFP+ ports for network traffic.

Management port

One RJ-45 port to access the device management interfaces through 
an Ethernet interface.

Console port

One RJ-45 port for connecting a serial console. Use the following 
settings:

• Data rate: 9600

• Data bits: 8

• Parity: none

• Stop bits: 1

• Flow control: none

USB port

One USB port for future use.

Table 10.   PA-3000 Series Electrical Specifications 

Specification

Description

Maximum internal power dissipation

PA-3020/PA-3050/PA-3060—250W AC

AC voltage

100-240 VAC

Summary of Contents for PA-3020

Page 1: ...PA 3000 Series Hardware Reference Guide...

Page 2: ...l refer to https www paloaltonetworks com documentation For access to the knowledge base complete documentation set discussion forums and videos refer to https live paloaltonetworks com For contacting...

Page 3: ...stall the Hardware 11 Tamper Proof Statement 11 Before You Begin 11 Equipment Rack Installation 13 Connect Cables to the Device 15 Connect Power 16 Chapter 3 Maintaining the Hardware 17 Cautions and W...

Page 4: ...4 Table of Contents Palo Alto Networks Chapter 5 Compliance Statements 25 VCCI 25 BSMI EMC Statement 25...

Page 5: ...0 Series PA 3020 PA 3050 and PA 3060 firewalls Front Panel on page 6 Back Panel on page 8 Note The port configuration on the PA 3020 and PA 3050 firewalls is identical the differences between the devi...

Page 6: ...net ports Twelve RJ 45 10 100 1000 ports for network traffic SFP ports Eight Small Form Factor Pluggable SFP 1 Gbit s ports for network traffic High availability HA ports Two RJ 45 ports for high avai...

Page 7: ...Gbit s ports for network traffic SFP ports Two Enhanced Small Form Factor Pluggable Plus SFP 10 Gbit s ports for network traffic High availability HA ports Two RJ 45 ports for high availability HA con...

Page 8: ...em Description AC power inlet and power supply Power inlet for device power Note The power supply is not customer serviceable Grounding lug To ground the system use a grounding wire of at least 14 Ame...

Page 9: ...ding wire of at least 14 American Wire Gauge AWG Attach the 14 AWG wire to an agency approved crimp connector Tyco 34120 or certified Lug crimped with the proper crimping tool and attached to the prot...

Page 10: ...Back Panel 10 Overview Palo Alto Networks...

Page 11: ...following upon receipt of each product The tracking number provided to you electronically when ordering the product matches the tracking number that is physically labelled on the box or crate The int...

Page 12: ...ify that power is not connected to the firewall On the PA 3020 and PA 3050 firewalls allow clear space on both sides of the firewall for side to side airflow On the PA 3060 firewall leave clear space...

Page 13: ...l Specifications on page 23 Reliable earthing Maintain reliable earthing of rack mounted equipment Pay special attention to supply connections other than direct connections to the branch circuit such...

Page 14: ...tion 14 Install the Hardware Palo Alto Networks Figure 5 PA 3020 and PA 3050 Rack Mount Brackets Figure 6 PA 3060 Rack Mount Brackets Mid mount position Front mount position 3 HA1 HA2 Mid mount positi...

Page 15: ...wall has eight SFP ports and eight copper Ethernet ports Refer to Front Panel on page 6 for descriptions of the front panel interfaces Figure 7 PA 3020 and PA 3050 Cable Connections CAUTION Shielded i...

Page 16: ...h a power cable to the device AC power inlet and plug the other end into a grounded wall outlet and the device will power on For the PA 3060 do the same but use two power cables on different circuits...

Page 17: ...r any unused fiber optical ports Do not look directly at exposed fiber optical transmitters or cables WARNING Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries ac...

Page 18: ...Green All fans are operating normally Red One or more fans have failed HA Green The device is active in an active passive configuration or is the active primary or active secondary in an active active...

Page 19: ...pply Simultaneously push down on the release lever and then pull the power supply outward to remove the power supply Figure 10 show how to remove and install a power supply 3 Slide a replacement power...

Page 20: ...Replace a PA 3060 Power Supply 20 Maintaining the Hardware Palo Alto Networks Figure 10 PA 3060 Power Supply Replacement...

Page 21: ...OMPANY CONFIDENTIAL Chapter 4 Specifications This chapter provides specifications for the PA 3000 Series firewalls Physical Specifications in the next section Interface Specifications on page 23 Elect...

Page 22: ...es 6 6 cm 1 5 RU Note The PA 3060 firewall is physically 2 6 inches or approximately 1 5 RU tall If a single device is installed it will consume 2 RU If you install two devices together using the prov...

Page 23: ...1000 ports for network traffic Small Form Factor Pluggable SFP ports PA 3020 PA 3050 Eight SFP ports for network traffic PA 3060 Eight SFP and 2 SFP ports for network traffic Management port One RJ 4...