12
Using the MicroCorr
Digital Correlator
BATTERY WARNING
All three batteries supplied are rechargeable lithium ion. Do not short circuit these
batteries. Any misuse of these batteries may result in explosion or fire. They must not
be used in any other application or used with any other equipment. Only
batteries/battery-packs supplied by Palmer Environmental must be used.
The Palmer sealed battery packs contain circuitry to prevent overcharging and
overdischarging.
Step 1: Charging and installing batteries
The battery packs for the correlator and the Out Stations are supplied as separate items and
will need to be fully charged although they are supplied quarter charged.
Two different battery chargers are supplied: one for the correlator and one for both Out
Stations to be charged simultaneously. All three batteries are identical and are
interchangeable. Charging for all batteries takes up to 4 hours from flat.
Charging the Correlator
1.
To charge the correlator battery, the battery must first be fitted inside the correlator.
2.
To insert the battery pack into the correlator unscrew the three screws underneath
the unit, remove the cover and packing foam and connect the battery pack, place in the
battery compartment, refit the packing foam, and then replace the cover with the three
screws.
3.
Connect the charge lead from the correlator charger to the headphone / battery
charge connector on the back of the correlator. Plug the charger unit into the mains supply
and switch on. The correlator will turn itself on and display the battery indicator as charging on
the correlation screen.
Unscrew these
3 quick-release
screws to
remove battery
compartment
panel.