- 14-
4.4.2 Modify the setting parameters
A, When the selected mode is running, the unit will run in accordance with the factory set default values or the
last modification of the temperature.
B, The modification method of set the temperature value
In the On or Standby cases, press M and
keys at the same time 3 seconds, the current operation mode
flashes; by pressing the M key, you can switch the sequence in the following order: cooling/heating/DHW;
Press
, the number will flash, then press the
▲ or ▼
to change set up fixed value, press
key to confirm
change and press
to exit . If not press
, it will quit automatically after 15 seconds without saving
amendment.
C, The detailed settings in the table below
Item
meaning
Setting range
default Change setting date
1
AC cooling
10℃
~
25℃
12℃
M+
→M→▲or▼→ →
2
AC heating
(AU)
10
℃~
55
℃
45℃
3
Hot water
(AU)
10
℃~
60
℃
50℃
4
Antibacterial
60℃
~
70℃
65℃
D
、
Antibacterial setting
Time setting procedure for health sterilization
Only in sanitary hot water mode, health sterilization will work. If sanitary hot water mode off, health
sterilization will fail to work.
In on or standby mode, first, press key M and
for 3 seconds, second, press key M ,15 icon appears,
then press the ▲ or ▼ to set sterilization temperature, press key
to confirm, the number of days will
flash and show the original or default value 7 (that means 7 days), press key ▲ or ▼ to increase or
decrease the number of days at predetermined intervals, the minimum of 7 days, maximum of no more than
99 days, after that ,press key
to confirm. At this time, "ON" character appears, "hour" appears and
flashes, show the original setting or the default value (default value 01 means it will start at 1:00 am),
followed by press key ▲ or ▼ to modify (0-23) ,after that, press key
to confirm, then the new time
start running. "ON" character disappears, "OFF" character appears, "minute" value flashes and shows the
original or default value (default value is 10), followed by press key ▲ or ▼to change (minimum is 10,
maximum no more than 99), after that press key
to confirm and exit change mode. If didn’t press key
to confirm, machine will exit change mode automatically after 15 seconds. But settings did right now
will become invalid.
4.4.3
、
clock setting
press
key, week icon flash
,
:
press▲ ▼ to set the date
,
press
for confirmation
。
Then the hour digit flash. As below: