background image

2

RETURN LINE FILTERS

s e r v i c e  

i n s t r u c t i o n s

Athalon

®

UR629/649/669/689 Series

1 Specifications 

Housing materials:

Head, tube, manifold 
and check valve: 

Aluminium Alloy

Cover: 

 

Cast iron

Maximum operating pressure:

28 bar (400 psi)

Proof pressure:

42 bar (609 psi)

Minimum burst pressure:

145 bar (2100 psi)

Element collapse:

UE610 element 10 bard (150 psid) differential minimum

Operating temperature range:

-29° C to 120° C (-20° F to 250° F) with fluorocarbon seals for 

petroleum based and specified synthetic fluids
60° C (140° F) maximum in HWCF, water-oil emulsion or water 

glycol

Bypass valve setting options:

1.7 ± 0.3 bard (25 ± 5 psid) cracking pressure
4.5 ± 0.3 bard (65 ± 5 psid) cracking pressure
Non bypass

Seals:

Fluorocarbon
The actual operating conditions should be checked by the 

user to ensure that the element, housing and all seals are 

compatible with the fluid and application, and are within local 

safety codes. Please contact Pall or approved distributor if 

further information is required.

Receipt of equipment 

The filter housing, and any optional equipment, are packed 

individually for assembly by the customer. Unpack carefully 

and ensure optional items are not mislaid in packaging to be 

discarded.

General sources of information 

3.1   For dimensions, operating parameters, assembly/

element part number, ordering information, notes, 

performance data and specifications refer to datasheet 

IMUR629EN.

3.2   This equipment has been assessed in accordance with 

the guidelines laid down in the European Pressure 

Directive 2014/68/EU and has been classified within 

sound engineering practice S.E.P. We hereby declare 

the equipment meets the requirements of article 4, 

paragraph 3, thus meeting the directive requirements. 

Under the provisions of this directive the filter assembly 

is suitable for use with group 2 fluids only.

3.3   Where under reasonably foreseeable conditions, 

including external fires, the allowable limits could be 

exceeded, suitable protective devices must be installed 

by the customer within the connecting fluid system.4.1 

 The filter can be installed in any attitude, but for ease of 

servicing, it is recommended that it be installed vertically 

with the filter tube and cover pointing upwards.

Installation of housing

4.1   The filter can be installed in any attitude, but for ease of 

servicing, it is recommended that it be installed vertically 

with the filter tube and cover pointing upwards.

4.2   The minimum clearance required for element removal of 

is as follows: 

 

4.2.1  443mm or 17.5” for length 20 and 951mm or 37.5” 

for length 40 assemblies.

 

4.2.2 The UR629 Housing is supplied without a filter  

 

 

element. For element installation and servicing  

 

 

procedures, refer to Section 7.

4.3   Threaded differential pressure devices, when fitted, must 

be torque tightened to 30-33 ft/lb or 40-45 Nm. All visual 

indicators must be clearly visible.

NOTE: The UR629 housing is supplied with two machined 

differential pressure warning device ports, one fitted with 

a bleed plug, the other with a plastic shipping plug. If no 

differential pressure warning device is ordered, the shipping 

plug must be removed and replaced with a ‘B’ type blanking 

plug (P/N HA9000-P8-Kit Z) and torque tightened to 40 ft/lb 

/54 Nm.  
NOTE: Never place the port plug in this port without first 

installing uniform size -014 O-ring in lower O-ring groove, 

otherwise a small bypass flow will result, allowing contaminant 

downstream of the filter element. 

4.4 

 Mount the filter assembly using the four 14.3 mm diameter 

holes in the manifold assembly.

4.5   Use a check valve downstream of the filter if there is a 

possibility of reverse flow.

4.6   Install the filter housing using additional piping/valving 

to allow complete filter assembly bypass if filter 

maintenance is required without system shutdown.

NOTE: Piping supports should be provided as close as is 

practicable to the port connections in order to minimize 

external loads. This filter assembly must not be electronically 

isolated from the users earthing system. This filter assembly 

must be earthed by connecting the users earthing system to 

one of the inlet/outlet connections.

4.7   Connect lines or hoses to housing inlet and outlet ports.

NOTE: Painting of the filter housing is optional. The coating 

on the filter housing is a suitable painting base. Cover the 

differential pressure warning device and nameplate if painting 

of the housing takes place.

CAUTION: 

Maximum surge flow should not exceed 1.3 times  

normal flow.

WARNING:

USE FITTINGS OR ADAPTORS COMPATIBLE WITH 

PORTS SUPPLIED AS SHOWN BY PART NUMBER 

ON NAMEPLATE AND NOTED IN DATA SHEETS: 

USE OF INCORRECT FITTINGS OR ADAPTORS CAN 

CAUSE FILTER HOUSING OR MANIFOLD FAILURE 

RESULTING IN LOSS OF PRESSURE AND POSSIBLE 

SYSTEM FAILURE OR PERSONAL INJURY.

CAUTION:

Reverse flow through filter element will cause damage.

CAUTION:

Never operate the filter unless both warning device 

ports are sealed.

Summary of Contents for UR629 Series

Page 1: ...UR629 649 669 689 EN UR629 649 669 689 Service Instructions service instructions ENGLISH EN ES DE FR JP CN IT KR M ESIUR629 649 669 689ENd UR629 649 669 689 Series...

Page 2: ...alled vertically with the filter tube and cover pointing upwards 4 2 The minimum clearance required for element removal of is as follows 4 2 1 443mm or 17 5 for length 20 and 951mm or 37 5 for length...

Page 3: ...sure is excessive filter may be undersized refer to the sizing and selection section of the product literature or contact your local Pall representative 5 5 Make sure element change labels are clean a...

Page 4: ...or your local Pall distributor Pall offers a fluid contamination analysis service consult the Pall sales office 4 Figure 1 Switch Circuit Diagram C or black or tag 2 A or white or tag 1 B or red or t...

Page 5: ...accompanied by full particulars including system operating conditions if applicable Seller shall not be liable for any product altered outside of the Seller s factory except by Seller or Seller s aut...

Page 6: ...to Centre Post upper OR243 O ring 104 37x3 53 Shell Assembly to Head OR014 O ring 12 42x1 78 Differential Pressure Indicator Commuter Valve OR261 5 O ring 172 06x3 53 Head to Bowl OR232 O ring 69 44x...

Page 7: ...7 ENGLISH RETURN LINE FILTERS service instructions UR629 649 669 689 Series Athalon UR699 Series 2 4 8 7 or 9 3 1 Figure 2 12 7 or 9 6a 13 10 5 11...

Page 8: ...RETURN LINE FILTERS service instructions Athalon UR629 649 669 689 Series 8 14 7 or 9 7 or 9 Figure 3 5 1 16...

Page 9: ...ad over volle diepte 4st f sth l G nga Z Min g ngdjup AA GG Q Flange Connection Details Flange Code Nominal Tube Size GG Q Z Thread AA E20 11 4 1 250 2 625 1 2 13 UNC 0 75 G20 11 4 31 8 mm 66 7 mm M12...

Page 10: ...to verify that this information remains valid Copyright 2019 Pall Corporation Pall and Athalon are trademarks of Pall Corporation Indicates a trademark registered in the USA Better Lives Better Plane...

Reviews: