7

Filter element servicing

During servicing, the external surfaces of the filter assembly
must be cleaned to remove any dust deposits.
Servicing must be conducted using suitable tools that do not
present a hazard. 
Servicing must not be carried out when a potentially explosive
atmosphere is present.

Refer to Service Parts List (Section 10) for item numbers for
applicable replacement element series. Remove and replace
element as follows:

7.1

Turn off and depressurize the system.

7.2

Unscrew and remove filter bowl (2) from head assembly
(1), anti-clockwise when viewed from below. It maybe
necessary to use a 1" socket wrench on the hexagon to
loosen the bowl initially.

7.3

Drain fluid from the bowl into a suitable waste container.

7.4 

Element replacement (UE209 Series): Remove filter
element (5) by turning clockwise (when viewed from 
below) and gently pulling the element from the filter 
head (1). Carefully inspect the interior surface
(flow through the element is in-to-out) for visible
contamination. Normally no dirt should show, but visible
dirt or particles can be an early warning of system
component failure. Discard both the filter element and 
its O-ring. The filter element is NOT CLEANABLE. 
Any attempt to clean the filter element can cause
degradation of the filter medium and allow contaminated
fluid to pass through the filter element.

7.5 

DO NOT run the system without a filter element
installed. Check that the O-ring (3) between the head (1)
and bowl (2) is not damaged. Use the replacement filter
as indicated by the part number on the element endcap.

7.6 

Lubricate element O-ring with clean system fluid. 
Reinstall element in the filter head (1) by engaging 
element and turning anti-clockwise until the element 
tabs lock into the filter head. Lightly lubricate head-to 
bowl O-ring with clean system fluid and reassemble the 
until thread bottoms. Hand tighten only. O-ring sealing is
not improved by over tightening

7.7 

Bleed the system and check for leaks as per
section 4.8.

7.8 

After element change, ENSURE VISUAL INDICATOR IS 
RESET BY PUSHING IN THE RED BUTTON. Electrical 
differential pressure devices will reset automatically. 
When system reaches normal operating temperature, 
check that the switch has not actuated and/or the visual
warning button has remained depressed. If visual 
indicator rises due to a cold start condition, reset again 
as per section 6.

8

Fluid sampling

Optimum sampling to verify fluid condition can be achieved by
the use of sampling adaptors installed on the hydraulic system
itself. For more information consult Pall or your local Pall
distributor. Pall offers a fluid contamination analysis service -
consult the Pall sales office.

Warranty, Limitation of Liability 
and Remedies

THERE IS NO WARRANTY OF MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE WITH RESPECT
TO ANY OF THE PRODUCTS, NOR IS THERE ANY OTHER
WARRANTY EXPRESS OR IMPLIED, EXCEPT AS PROVIDED
FOR HEREIN.
For a period of twelve months from the date of delivery from
Seller or three thousand hours of use, whichever occurs first
(the "Warranty Period"), Seller warrants that products
manufactured by Seller when properly installed and
maintained, and operated at ratings, specifications and design
conditions, will be free from defects in material and
workmanship. By way of explanation and not limitation, the
Seller does not warrant the service life of the filter element as
this is beyond the Seller's control and depends upon the
condition of the system into which the filter is installed.

CAUTION: 
Filter elements should be replaced upon indication 
or at specified intervals, six months maximum. 
Failure to change the element will cause the filter to 
go on bypass.

WARNING:
FAILURE TO DEPRESSURISE THE FILTER BEFORE
SERVICING ELEMENT COULD RESULT IN
EXPLOSIVE LOSS OF FLUID, DAMAGE TO
EQUIPMENT AND POSSIBLE PERSONAL INJURY.

UR209

UR209 Series

R E T U R N   L I N E   F I LT E R S

s e r v i c e  

i n s t r u c t i o n s

3

WARNING:
DO NOT ATTEMPT TO CLEAN OR RE-USE 
THE ELEMENT.
ONLY USE GENUINE PALL REPLACEMENT FILTER
ELEMENTS. USE OF SUBSTITUTE ELEMENTS MAY
INVALIDATE PRODUCT WARRANTY.

Summary of Contents for UR209 Series

Page 1: ...service instructions UR209 UR209 Series 1372872 IM SI UR209 EN UR209 Service Instructions ENGLISH ...

Page 2: ...ease of servicing it is recommended that it be installed vertically with the filter bowl pointing downwards 4 2 The minimum clearance required for element removal is 69 mm 2 7 for all lengths 4 3 The UR209 series housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 NOTE The UR209 head is supplied with one machined differential pressure w...

Page 3: ...appropriate new labels 6 Differential Pressure Devices Reference should be made to product literature for dimensions operating parameters part numbering ordering information and specifications 6 1 Differential pressure devices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If the differential pressure switch actuates during cold start contin...

Page 4: ...he system and check for leaks as per section 4 8 7 8 After element change ENSURE VISUAL INDICATOR IS RESET BY PUSHING IN THE RED BUTTON Electrical differential pressure devices will reset automatically When system reaches normal operating temperature check that the switch has not actuated and or the visual warning button has remained depressed If visual indicator rises due to a cold start conditio...

Page 5: ...utor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in use storage transportation or handling In no event will Seller be liable for any damage...

Page 6: ...UR209 UR209 Series s e r v i c e instructions 5 2 4 5 Figure 1 Refer to product literature 3 1 Not shown on this diagram Inlet RETURN LINE FILTERS ...

Page 7: ...UR209 UR209 Series s e r v i c e instructions 6 RETURN LINE FILTERS ...

Page 8: ...nd IMSIUR209 Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan Thailand United Arab E...

Reviews: