palintest Pooltest 3 Manual Download Page 1

 

 

2

 

Table of Contents 

1

GENERAL INFORMATION 

...................................... 3

Introduction to Palintest Photometers 

......................... 3

Kit Contents ............................................................. 4

Instrument Layout .................................................... 6

BACKGROUND INFORMATION ............................. 7

Introduction to Colorimetric Measurement .................. 7

Blanks and Samples .................................................. 9

Taking a Reading 

...................................................... 9

Care and Maintenance ............................................ 10

TEST PROCEDURES ............................................. 

12

Chlorine ................................................................. 14

pH 

......................................................................... 17

Cyanuric Acid ......................................................... 18

Alkalinity (Total) ..................................................... 19

Calcium Hardness ................................................... 20

Bromine 

................................................................. 21

INSTRUMENT ...................................................... 

22

Technical Specification ............................................ 24

5

TROUBLESHOOTING ........................................... 

26

Chemistry Troubleshooting ...................................... 26

Water Balance ........................................................ 29

Sample Dilution and Collection ................................. 33

REORDER CODES and ACCESSORIES ................. 

34

 

 INST.36 

 

 

3

 

GENERAL INFORMATION 

Introduction to Palintest Photometers 

Thank you for purchasing this Palintest product.   

Palintest  instruments  and  reagents  are  renowned  as 

being  simple  to  use,  whilst  providing  rapid  and  reliable 

results  for  the  testing  of  water.  Our  instruments  are  of 

the highest quality and fully waterproof. 

Palintest’s  experience,  built-up  over  the  last  50  years, 

is  the  reason  why  our  instruments  and  reagents  are 

used  in  laboratories,  treatment  plants,  leisure  facilities 

and industrial premises throughout the world. 

Our  products  are  packaged  carefully  and  the  product 

should  reach  you  in  the  state  it  left  our  factory;  if  this 

product  has  reached  you  in  a  state  that  is  less  than 

satisfactory,  please  contact  your  local  Palintest  branch 

or your local distributor. 

This  booklet  describes  the  best  way  to  use  Palintest 

products,  and  provides  instructions  for  the  range  of 

water tests that can be performed using this instrument. 

Palintest  instruments  are  calibrated  for  Palintest 

reagents. 

To 

guarantee 

the 

high 

accuracy 

and 

performance  that  our  instruments  give,  you  must 

ensure  that  only  Palintest  reagents  are  used  with 

Palintest  instruments.    Failure  to  do  so  can  lead  to 

erroneous results. 

Summary of Contents for Pooltest 3

Page 1: ...lts for the testing of water Our instruments are of the highest quality and fully waterproof Palintest s experience built up over the last 50 years is the reason why our instruments and reagents are u...

Page 2: ...Rods Test Tube Brush Photometer Tubes Reagents Chlorine Free and Total pH Phenol Red Cyanuric Acid Alkalinity Calcicol Bromine For re ordering codes and accessories please see Section 6 If you have b...

Page 3: ...easurement between test samples and colour standards a colorimeter can be used for quantitative measurement of the amount of coloured light absorbed by a sample with reagents added in reference to a u...

Page 4: ...l quantities of red light pass through the solution 9 Blanks and Samples Palintest photometers use a BLANK tube to set the instrument to blank and a SAMPLE tube to take the reading A BLANK tube is a t...

Page 5: ...drips or condensation before placing in the photometer 5 Do not leave tubes standing in the photometer test chamber Remove the tubes immediately after each test 6 Immediately wipe up any drips or spil...

Page 6: ...1 5 mg l range Cl2 10 Chlorine Free and Total 0 01 10 mg l range pH pH pH Units CNA Cyanuric Acid Alk T Alkalinity Total Calc Calcium Hardness Calc NaCl Calcium Hardness Salt Water Pools Only Br Bromi...

Page 7: ...ion remaining from the Free Chlorine test 2 If any non chlorine shock treatment chemicals have been added to the pool see additional notes below 3 Add one DPD No 3 tablet or DPD XT for high range inst...

Page 8: ...cal Palintest branch distributor or see www palintest com Reagents AP 011 DPD No 1 Tablets Low Range AP 013 DPD XF Tablets High Range AP 031 1 DPD No 3 Tablets Low Range AP 033 1 DPD XT Tablets High R...

Page 9: ...sample to the 10 ml mark 2 Add one Alkaphot tablet crush and mix until all the particles have dissolved It is important to ensure that all of the tablet particles have dissolved otherwise the result...

Page 10: ...standard Calcicol test is still valid Magnesium hardness up to 200 mg l as CaCO3 does not interfere with the test Iron at levels above 10 mg l may cause low results Zinc above 5 mg l may cause high r...

Page 11: ...ng systems is recommended The crossed out wheeled bin symbol on the meter encourages you to use these systems when disposing of this equipment Error Messages The photometer will display an error messa...

Page 12: ...ight transmission and affect readings To clean the optics gently clean the internal surfaces of the optics with a soft non abrasive cloth Do not use solvents Deposits may be removed with a slightly da...

Page 13: ...S are used to oxidise organic contaminants in the water and regenerate free chlorine from chloramines Typical products are Oxybrite Oxysure and Purolyte Plus 27 Excess MPS reacts in the DPD test It do...

Page 14: ...mg l Ca multiply by 0 4 29 Bromine For most purposes it is sufficient to simply measure the total bromine residual using DPD No 1 tablets since both free and combined bromine are active disinfectants...

Page 15: ...ness Alkalinity as mg l CaCO3 Factor 20 1 0 200 2 0 30 1 2 250 2 1 40 1 3 300 2 2 50 1 4 350 2 25 66 1 5 400 2 3 80 1 6 500 2 4 90 1 65 550 2 45 100 1 7 600 2 5 125 1 8 700 2 55 150 1 9 800 2 6 31 5 C...

Page 16: ...the European CE Mark of Compliance for electro magnetic compatibility EMC 33 Sample Dilution and Collection When the test result is outside the concentration range of the test the photometer will disp...

Page 17: ...087 AP 087 Alkaphot PM 188 AP 188 Calcicol PM 252 AP 252 EDTA Tablets AT 090 DPD Oxystop AP 017 Accessories Description Product Code Test Tube Brush PT 663 Replacement Photometer Tubes x5 PT 555 Photo...

Reviews: