32
00 4776980 - 06/2018 - PN - Italy
INSTALLATION
6.3 ASSEMBLY DIAGRAM
(Fig. 6.3)
A) For proper installation, the smoke ducting between the
¿
replace and the
À
ue must have all joints sealed.
B) Rear external air intake, ensure a minimum distance of 5
cm between cladding and combustion air intake pipe.
C) UNI standards require the installation of a heat recovery
grille as close as possible to the ceiling.
D) Counter-hood
and
¿
reproof load-bearing structure
E) Cladding
in
ceramic
¿
bre or rock wool with external
aluminium foil
F) Protect any wooden parts with
¿
reproof material.
G) Min distance. 1 cm between cladding and
¿
replace stove
H) The cladding must be made of
¿
reproof material
Fig. 6.3.1
In the product technical detail shows the
minimum distances in centimeters to be observed
in the placement of the
¿
replace with respect to
materials and combustible objects.
Leave enough room for maintenance
Assembly must be carried out by qualified
personnel.
• If
there
are
À
ammable materials or structures
on the back of the
¿
rebox, they must be at a
minimum distance of 10 cm.
•
To ensure correct installation, the smoke pipe
between the
¿
replace and
À
ue must be airtight,
sealing all the joints.
• If the fireplace is installed with a flue that
has already been used with other
¿
replaces,
it should be cleaned thoroughly to avoid
malfunctions and the danger of unburned parts
deposited on the inside from catching
¿
re.
• Improper installation may compromise the
safety of the unit.
• It must be possible for quali
¿
ed personnel to
access the inside of the stove when it is not in
operation.
•
The cladding must be in
¿
reproof material and
it must not have any removable parts, so that
electrically powered and moving parts are not
accessible by the user.
• Do
not
place
À
ammable objects or materials
in the radiation area of the hearth, and in any
case not less than 1 m.
Fig. 6.3
A
B
E
C
D
F
G
H
DISTANZA MINIMA DAI MATERIALI COMBUSTIBILI
X1
X2
Y1
Y2
Z
Fig. 6.3.1