4.3 Technical features
LINDA US
LINDA US 9
LINDA US 12
Min
Max
Min
Max
Overall thermal power (output)
kcal/h 3095,44 7738,61 3095,44 10318,14
kW
3,6
9
3,6
12
Yield
%
94
92,4
94
91,3
Flue gas temperature
°C
69,3
127,9
69,3
162,2
Flue gas flow rate
g/s
4,28
6,13
4,28
7,09
Hourly fuel consumption
kg/h
0,79
2,02
0,79
2,73
CO emissions (at 13% O2)
mg/
Nm
3
114
28
114
35
Flue gas outlet
mm
Ø 80
Outside air intake
mm
Ø 130
Fuel
Wooden pellets
Flue draught
Pa
12 (±2)
Minimum draught for chimney sizing
Pa
0,0
Stove suitable for rooms no smaller than
m
3
30
30
Feeding tank capacity
kg
16
Weight
kg
190
No. rear fans
no.
-
1 (Pro 2)
Rear fan flow rate
m
3
/h
-
140
Electrical data
LINDA US 9
LINDA US 12
Voltage
V
230
Frequency
Hz
50
Max power absorbed during operation
W
70
Power absorbed at electric ignition
W
370