Configuration 2 and 5:
To set the restart delta value:
a) Use the arrow buttons
to go to the setup menu
and then press
;
b) Use the
button to select the password “7” and then press
to confirm;
;
c) Select submenu
[8]
and press
to confirm;
d)
The value will flash; change it using the
and
buttons (
0,5 ... 5,0
°C);
e) Press the
button to confirm the set value.
Configuration 3 and 4:
To set the restart delta value:
a) Use the arrow buttons
to go to the setup menu
and then press
;
b) Use the
button to select the password “7” and then press
to confirm;
;
c) Select submenu
[8]
and press
to confirm;
d)
The value will flash; change it using the
and
buttons (
0 ... 40
°C);
e) Press the
button to confirm the set value.
10.7 MANUAL ACTIVATION OF THE LOAD SYSTEM
In case of first use (pellet tank initially empty) or to test operation of the load unit, manual activation of loading
is possible.
On the control panel of the stove:
a) Using the arrow keys
navigate to the set-up menu
and press the key
;
b) Select password "7" with the key
and confirm with the key
;
c) Scroll with the key
and select sub-menu
[3 1 ]
;
d) Select password "54" with the key
and confirm with the key
;
e) Holding the key
the load system will activate and the display will show the incremental bars
f) Releasing the key will end the load operation.
Attention!
•
This function is only active when the stove is off and cold.
• Before switching on again, ensure that there are no pellets in the grate.
10.8 SYSTEM INFORMATION
Thanks to this function, it is possible to access the system information:
a) Using the buttons
go to the setup menu
and confirm with the button
;
b) select the password “7” with the
key and confirm with the
key;
c) select the submenu
[39]
and confirm with the
key;
d) select the password “54” with the
key and confirm with the
key.
At this point, it will be possible to use the keys to move between the values of the sub-menus in the following
order:
• pellet consumed [kg] ;
• instantaneous power [kW] ;
• energy produced [MWh];
• instantaneous power consumption [dW];
•
Seasonal Energy Efficiency [%] (Ecolabel) (factory setting); Seasonal Energy Efficiency [%] (Ecodesign) (factory
setting).
Summary of Contents for EcoFire IDRO
Page 17: ...17 004772533 16 03 2021 ITALIANO USO E MANUTENZIONE...
Page 46: ...46 004772533 16 03 2021 USE AND MAINTENANCE...
Page 75: ...DEUTSCH 75 004772533 16 03 2021 BEDIENUNGS UND WARTUNGSANLEITUNG...
Page 104: ...104 004772533 16 03 2021 EMPLOI ENTRETIEN...
Page 133: ...ESPA OL 133 004772533 16 03 2021 USO Y MANTENIMIENTO...