6.3 INITIAL CONFIGURATION
Depending on the type of installation, the best configuration needs to be selected for stove operation.
Before proceeding, power up the stove using the safety switch on the rear.
Use the arrow buttons to scroll between the icons until reaching the setup menu
;
a) Use the arrow buttons
to go to the setup menu
and then press
;
b) Use the
button to select the password “7” and then press
to confirm;
c) Use the
buttons to scroll to and select submenu
[3 0]
; “
--0
” will flash on the display;
d) Press
and enter the value “54” using the
buttons;
e) Press
to confirm;
f)
The current configuration will be displayed;
g)
To change the configuration, press and enter the value of the new configuration using the
buttons;
h) Press
to confirm.
After having changed the configuration a communication error message may be displayed for a few
seconds. Ignore this and switch the stove off using the safety switch on the rear, wait a few seconds
and switch it back on..
FIVE DIFFERENT CONFIGURATIONS ARE AVAILABLE:
CONFIGURATION 1
Set this configuration when the stove is controlled by an external thermostat (or timer thermostat).
This configuration can also be used to switch the stove on or off manually or by timer without using an external
thermostat, but rather leaving the two terminals jumpered as per the factory setting.
In this configuration the stove switches off when reaching the external thermostat setting or alternatively
modulates output (to minimise fuel consumption) when reaching the set water temperature.
The stove will turn off also in case the water temperature continues to rise despite the modulation. In this case,
the stove will turn on only if the temperature difference between the value you set up and the real one is higher
than 20°C.
In this configuration, it is therefore recommended to regulate a high water temperature (ex. 70°C).
CONFIGURATION 2
Set this configuration to switch the stove on or off manually or by timer when the stove is connected directly to
the central heating radiators.
The stove will modulate output according to the room temperature read by the probe on the stove.
The “Eco-mode” function can be used to have the stove switch off or on based on the set room temperature.
The frost protection function can also be set in this configuration.
CONFIGURATION 3
Set this configuration when wanting to connect the stove to a storage tank with coil.
The stove will be controlled (switch on and off) based on the temperature read by the probe in the storage tank.
The frost protection function can also be set in this configuration.
CONFIGURATION 4
Set this configuration when wanting to connect the stove to a storage tank without coil.
The stove will switch on based on the temperature read by the probe in the storage tank, and will switch off
based on the stove return temperature.
The frost protection function can also be set in this configuration.
CONFIGURATION 5
Set this configuration only in conjunction with the “Everspring” system.
The stove will regulate the power according to the ambient temperature read by the sensor on the “Everspring”
system. It will also be possible to handle various levels of ventilation of “Everspring” directly from the stove. In
summer mode, the stove is able to activate a cooling system (if fitted) coupled to the “Everspring” system.
It is possible to set the “Eco-mode” function to ensure that the stove shuts off or restarts according to the room
temperature set.
Summary of Contents for EcoFire IDRO
Page 17: ...17 004772533 16 03 2021 ITALIANO USO E MANUTENZIONE...
Page 46: ...46 004772533 16 03 2021 USE AND MAINTENANCE...
Page 75: ...DEUTSCH 75 004772533 16 03 2021 BEDIENUNGS UND WARTUNGSANLEITUNG...
Page 104: ...104 004772533 16 03 2021 EMPLOI ENTRETIEN...
Page 133: ...ESPA OL 133 004772533 16 03 2021 USO Y MANTENIMIENTO...