SCHEMA ELETTRICO - WIRING DIAGRAM - SCHÉMA DE CÂBLAGE
ELEKTRISCHER SCHALTPLAN - DIAGRAMA DE CABLEADO - EL-DIAGRAM
ITALIANO
ENGLISH
FRANCAIS
DEUTSCH
ESPAÑOL
DANSK
1 Sensore di hall
Exhaust fan speed
sensor
Capteur de hall
Hall fuehler
Sonda regulad. Veloc.
Turbina humos
HALLSENSOR
2 Termostato esterno
Thermostat
Thermostat
Raumtemperaturregler
Termostato
EXTERNE
THERMOSTAAT
3 Sonda ambiente
Room probe
Sonde ambiant
Raumsonde
Sonda ambiente
KAMERSENSOR
4 Sonda pellet
Pellet probe
Sonde pellet
Pelletsonde
Sonda pellet
SONDE PELLET
5 Sonda fumi
Flue probe
Sonde des fumees
Rauchsonde
Sonda humos
ROOKGASSENSOR
6
Differenziale di
pressione
Pressure differential
Differential de
pression
Druckdifferenzial-sensor Diferencial de presion
DIFFERENTIEELRELAIS
DRUK
7
Resistenza ad
incandescenza
Igniter
Resistance Glutwiderstand
Resistencia
GLOEIWEERSTAND
8
Ventilatore scarico
fumi
Exhaust fan
Extracteur des
fumees
Abgasventilator
Turbina expulsion
humos
ROOKGASSEN
VENTILATOR
10 Dosatore caricamento Feeding system
Systeme
d’alimentation
Spender
Dosador
DOSEERINRICHTING
LADING
11
Termostato di
sicurezza
Thermostat
Thermostat
Raumtemperaturregler
Termostato
VEILIGHEIDSTHERMOSTAAT
12 Pressostato
Vacuum switch
Pressostat
Druckwaechter
Presostato
DRUKREGELAAR
13 Sensore porte
Door sensor
Sonde porte
Tuersonde
Sensor puerta
SENSOR DEUREN
air
14 Ventilatore ambiente Room fan
Ventilateur ambiant
Raumluftgeblaese
Ventilador de
conveccion
OMGEVINGSVENTILATOR*
15 Induttanza
Inductance
Inductance
Induktivität
Inductancia
:VSyáF]\QQLN
indukcji
UI /
PC
Pannello comandi
Display
Tableau de
commande
Steuerpaneel
Panel de mando
Panel sterowniczy
Air
comb
Pa
K
t°
t°
UI /
PC
11. USER INTERFACE
7. HALL SPEED SENSOR
9. ROOM PROBE
8. PELLET PROBE
10. FLUE GAS TEMP.
12.
INDUCTANCE
1. IGNITER
2. COMBUSTION FAN
4. PELLET AUGER
5. STB SAFETY
6. UNDER PRESSURE SAFETY
3. ROOM FAN
13. EXTERNAL THERMOSTAT
RED
GREEN (+)
BLUE
BLACK
1
7
11
8
9
10
2
4
5
6
3
12*
Air
comb
Pa
UI /
PC
DATA CABLE
K
t°
t°
cod. 00 472 3182 - ver. 08.2017
13
t° L
* Solo nei modelli ventilatore con condensatore
* Only in models with a condenser room fan.
O01
~220 - 240 Vac
O02
O03
O04
I01
T02
T01
T03
+
-
GND
PE
FUSE: T5A
C01
GND
BA
TTER
Y
: CR 20 32
F03
I02
F01/02 +VIO
L
N
~220÷240
Vac
PE
L
N
BLUE
BROWN
YELOW/GREEN
Summary of Contents for ECOFIRE AURORA U.S.
Page 7: ...7 00 477 7210 08 2018 PN Italy Fig 2 Fig 3 Fig 6 Fig 4 Fig 5...
Page 9: ...9 00 477 7210 08 2018 PN Italy Fig 2 Fig 3 Fig 6 Fig 4 Fig 5...
Page 11: ...11 00 477 7210 08 2018 PN Italy Fig 2 Fig 3 Fig 6 Fig 4 Fig 5...
Page 13: ...13 00 477 7210 08 2018 PN Italy Fig 2 Fig 3 Fig 6 Fig 4 Fig 5...
Page 15: ...15 00 477 7210 08 2018 PN Italy Fig 2 Fig 3 Fig 6 Fig 4 Fig 5...
Page 22: ......
Page 23: ......