Sensor B 39 and B 40
Sensor Position/Name
Adjustment
B39
Pusher ground position
When the package lift ejector is moved
manually, at least 75% of Sensor B39 must be
covered by the actuator. The distance between
sensor and actuator 0,5 – 1 mm
B40
Pusher working position
When the package lift ejector is moved
manually, at least 75% of Sensor B40 must be
covered by the actuator. The distance between
sensor and actuator 0,5 – 1 mm