background image

Model: 

  

GT-48A / C / CL-3P  3-point 

controlled gas-fired forced convec on air heater with axial fan  

B

1

 Warm air heater:  No

C

2

 Warm air heater:  No

C

4

 Warm air heater:  No

Type of fuel:                Gas

Item 

Symbol  Value 

Unit 

Item 

Symbol  Value 

Unit 

Capacity

 Useful efficiency

Rated 
hea ng capacity 

P

rated,h

45,1

kW

Useful efficiency at rated 
hea ng capacity 

nom

83,4

%

Minimum 
capacity 

P

min

35,2

kW

Useful efficiency at minimum 
capacity 

pl

82,4

%

Electric power consump on 

Other items 

At rated hea ng 
capacity 

el

max

0,095

kW

Envelope loss factor 

F

env

0,0

%

At minimal 
capacity 

el

min

0,074

kW

Igni on burner power 
consump on

P

ign

0,0

kW

In standby 
mode 

el

sb

0,0

kW

Emissions of nitrogen oxides

NOx

93

mg/kWh input 

energy (GCV)

Regula on (EU) 2016/2281 

Emission efficiency

s,flow

93,03

%

Seasonal space hea ng energy 
efficiency

s,h

72,4

%

Model: 

  

GTV-E-48A / C / CL-MOD Modulated I

ndirect gas-fired forced convec on air heater with axial fan

B

1

 Warm air heater:  No

C

2

 Warm air heater:  No

C

4

 Warm air heater:  No

Type of fuel:                Gas

Item 

Symbol  Value 

Unit 

Item 

Symbol  Value 

Unit 

Capacity

 Useful efficiency

Rated 
hea ng capacity 

P

rated,h

45,1

kW

Useful efficiency at rated 
hea ng capacity 

nom

83,4

%

Minimum 
capacity 

P

min

35,2

kW

Useful efficiency at minimum 
capacity 

pl

82,4

%

Electric power consump on 

Other items 

At rated hea ng 
capacity 

el

max

0,095

kW

Envelope loss factor 

F

env

0,0

%

At minimal 
capacity 

el

min

0,074

kW

Igni on burner power 
consump on

P

ign

0,0

kW

In standby 
mode 

el

sb

0,0

kW

Emissions of nitrogen oxides

NOx

93

mg/kWh input 

energy (GCV)

Regula on (EU) 2016/2281

Emission efficiency

s,flow

93,03

%

Seasonal space hea ng energy 
efficiency

s,h

72,9

%

Contact 
details 

 PAKOLE Trade K .  H-8000,   Székesfehérvár,  Börgöndi út,  8-10

Summary of Contents for GTV-E-107A

Page 1: ...ole com U M 009_027_011_181010_V001_EN AIR HEATERS BURNING GASEOUS FUELS Appliance types GTV E 20A C CL GTV E 27A C CL GTV E 33A C CL GTV E 40A C CL GTV E 48A C CL GTV E 58A C CL GTV E 68A GTV E 87A G...

Page 2: ...t 9 Electrical connecting speci cation 9 Regulation possibilities 10 6 A 10 Ventilation 10 Protective distances 11 7 A 11 Start restart 11 Control and regulation of appliance 12 8 M 13 13 Maintenance...

Page 3: ...reach your gas supplier call the Fire Department The GTV E type warm air blower appliances have been developed and certi ed in compliance with MSZ EN 1020 standard and quali ed for heating of industri...

Page 4: ...do not leave it to grow old Do not use seriously aged equipment any longer Fix the appliance on such stable surface which during operation despite warming of appliance preserves its stability If the...

Page 5: ...ll the Manufacturer o ce or the closest dealer www pakole com and ask for further informa tions ATTENTION COMPULSORY EARTHING ATTENTION ONLY QUALIFIED PERSON CAUTION DANGER CAUTION ELECTRIC SUPPLY Acc...

Page 6: ...et until the gas attachment investigate the device if it is not damaged during the transportation if it is damaged in that case notify the retailer from whom the device was bought There is an envelope...

Page 7: ...able conditions for the formation of NOx which are the result of the formation of ame and high ame temperatures and the long residence time of the molecules in the ame during combustion ATTENTION Duri...

Page 8: ...through the attached air duct system to the demanded places 4 picture Centrifugal fan type with air duct execution C GTV E CL 5 picture Air duct execution at CL type SOLELY INTERIOR installa on is po...

Page 9: ...ked The appliance has I class protection against electric shock for this reason it must be supplied with wired protection against electric shock The appliance must be operated under dry circumstances...

Page 10: ...matic burner control located in the appliance receives and processes the transmitted control signals from the temperature regulator transmitted by the mentioned control cable and as a function of thes...

Page 11: ...witch is changed during operation namely switches over from work switched on position to ba sic standstill position in that case the automatic electronic control stops the gas supply by closing of mag...

Page 12: ...owers can be operated by AHP 3 and AHP MOD type temperature regulator which may be purchased at appliance manufacturer In case of using different temperature regulator please contact with the manufact...

Page 13: ...utlet of solenoid valve check of the condition of pressure regulator check of the protective ground check of the electrical connection check of the exhaust fan and circulating fan check the free rotat...

Page 14: ...t the local authorized representative or a qualified service department G ATTENTION This action can only be realized by qualified expert or service ATTENTION If the heater appliance is working than it...

Page 15: ...80 6410 Q 1 1 1 1 1 1 D T C 24 1 24 9 24 5 24 7 25 2 25 A 12 16 18 20 22 25 E 100 100 G G1 2 ISO 228 OD E 230V 50H N AVERAGE A 0 9 0 9 1 77 1 77 1 9 1 9 E W 0 21 0 21 0 41 0 41 0 44 0 44 N B A 53 53 5...

Page 16: ...228 OD E 230V 50H N AVERAGE A 7 9 4 1 7 9 4 1 8 3 5 8 3 5 9 2 6 9 2 6 E W 943 943 1150 1150 1380 1380 N B A 56 58 56 58 58 58 W C 70 93 121 IP CL 75 98 126 IP21 T Input Output Gas consumption 3 L 3 L...

Page 17: ...0 625 805 187 GTV E 48A 750 650 625 805 252 GTV E 58A 750 650 625 805 252 Type A a b M e GTV E 20C 470 370 625 990 135 GTV E 27C 470 370 625 990 135 GTV E 33C 610 510 625 1040 187 GTV E 40C 610 510 62...

Page 18: ...a b c d M D e GTV E 20CL 470 350 600 350 500 1050 50 135 GTV E 27CL 470 350 600 350 500 1050 50 135 GTV E 33CL 610 500 600 400 550 1100 50 187 GTV E 40CL 610 500 600 400 550 1100 50 187 GTV E 48CL 750...

Page 19: ...i2E 20 LU DE i3P 37 BE FR 50 CY DE i2H3P 20 28 30 BA BG MD RO RU SK UA HR RS 20 37 CH ES GB IE PT SI 20 28 30 37 CZ GR IT 20 50 AT TR i2E3P 20 37 PL i2HS3P 25 28 30 50 HU The appliances were tested t...

Page 20: ...ission e ciency s ow 93 28 Seasonal space hea ng energy e ciency s h 72 7 Model GTV E 20A C CL MODModulatedIndirectgas redforcedconvec onairheaterwithaxialfan B1 Warm air heater No C2 Warm air heater...

Page 21: ...on e ciency s ow 93 27 Seasonal space hea ng energy e ciency s h 72 9 Model GTV E 27A C CL MODModulatedIndirectgas redforcedconvec onairheaterwithaxialfan B1 Warm air heater No C2 Warm air heater No C...

Page 22: ...ciency s ow 92 79 Seasonal space hea ng energy e ciency s h 72 3 Model GTV E 33A C CL MOD Modulated Indirect gas red forced convec on air heater with axial fan B1 Warm air heater No C2 Warm air heater...

Page 23: ...ciency s ow 93 1 Seasonal space hea ng energy e ciency s h 72 6 Model GTV E 40A C CL MOD Modulated Indirect gas red forced convec on air heater with axial fan B1 Warm air heater No C2 Warm air heater...

Page 24: ...iency s ow 93 03 Seasonal space hea ng energy e ciency s h 72 4 Model GTV E 48A C CL MOD Modulated Indirect gas red forced convec on air heater with axial fan B1 Warm air heater No C2 Warm air heater...

Page 25: ...ciency s ow 92 91 Seasonal space hea ng energy e ciency s h 72 3 Model GTV E 58A C CL MOD Modulated Indirect gas red forced convec on air heater with axial fan B1 Warm air heater No C2 Warm air heater...

Page 26: ...ciency s ow 93 24 Seasonal space hea ng energy e ciency s h 72 9 Model GTV E 68A MOD Modulated Indirect gas red forced convec on air heater with axial fan B1 Warm air heater No C2 Warm air heater No C...

Page 27: ...ciency s ow 92 13 Seasonal space hea ng energy e ciency s h 72 1 Model GTV E 87A MOD Modulated Indirect gas red forced convec on air heater with axial fan B1 Warm air heater No C2 Warm air heater No C...

Page 28: ...ciency s ow 92 68 Seasonal space hea ng energy e ciency s h 72 2 Model GTV E 107A MOD Modulated Indirect gas red forced convec on air heater with axial fan B1 Warm air heater No C2 Warm air heater No...

Page 29: ...e station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case of accidentally happened or directly caused mistake respectively improper us...

Page 30: ...PAKOLE TRADE LLC H 8000 Sz kesfeh rv r B rg ndi t 8 10 http www pakole com E mail mail pakole hu Tel 36 22 316 484 Fax 36 22 316 074 www pakole com...

Reviews: