Section 363-712-131-01
February 24, 1998
Revision 01
Page 36
PairGain Engineering - Plant Series
PG-Flex FLL-712 List 3A
Table 8 defines the functions of the metallic access menu parameter selections.
Table 8. Metallic Access Menu Options
Type
Letter
Parameter
Function
A
COT - Bridging
Provides the ability to monitor a subscriber circuit connection between
the switch and the specified CO channel unit Tip/Ring pair.
B
COT - Looking In
Provides the ability to verify the connection between the switch and the
specified channel unit Tip/Ring pair. The channel under test is
disconnected from the switch for this function. The technician will be
able to verify connectivity of the channel under test back to the switch.
C
COT - Looking Out
Provides the ability to stimulate the subscriber connection through the
CO channel unit. The switch is disconnected from PG-Flex for this
function.
D
RT - Looking In
Provides the ability to monitor the subscriber circuit at the RT channel
unit Tip/Ring pair with the subscriber terminal equipment disconnected.
E
RT - Looking Out
Provides the ability to verify the channel the subscriber drop off with
the RT channel unit disconnected.
F
RT - Bridging
Provides the ability to monitor the connection between the RT channel
unit and the subscriber terminal equipment.
G
Subscriber Bypass
Provides a metallic connection from the switch to the subscriber’s
terminal equipment for the selected channel, bypassing the PG-Flex
carrier transport. This is the only access connection that can be
maintained after the technician logs off the maintenance port.
3
From the Metallic Access Menu, type a letter (A through G) then press <Enter>. The Metallic
Access selection menu displays: