Section 363-712-131-01
February 24, 1998
Revision 01
Page 8
PairGain Engineering - Plant Series
PG-Flex FLL-712 List 3A
6. Terminal Management
6.1
The terminal management function allows a technician to manage the entire PG-Flex system using
an ASCII terminal (or modem with a null modem cable) connected to the Craft port. With this
function, you can:
•
view system status
•
set configuration parameters
•
set metallic access connection to the subscriber circuit
•
monitor system performance
•
obtain an inventory report
6.2
Connecting FLL-712 to a Terminal or Modem.
Figure 4 shows the pinouts for connecting the
FLL-712 Craft port to an ASCII terminal.
The FLL-712 line unit will not automatically log off when a terminal is unplugged
from the craft maintenance port unless the DTR signal is connected between
the terminal and the Craft port. Technicians must manually log off the line unit
before unplugging from the port. Otherwise, the line unit remains logged in,
and the terminal session will still be in the same place.