Monitoring System Activity and Performance
152-319-100-02, Revision 02
32
April 21, 2000
H2TU-C-319 List 1 and List 1C
U
SING
THE
P
ERFORMANCE
S
CREENS
TO
V
IEW
A
LARM
D
ATA
To access the alarm history screens:
1
Press
to select the Performance screen.
2
Press the
to select an interface (H2TU-C DS1, H2TU-R DS1, H2TU-C HDSL2, or
H2TU-R HDSL2), then press
.
3
Press the
until Alarm History is selected, then press
.
•
Press
or
to page through the alarm history screens.
•
Press
to clear the selected alarm history screen.
Alarm History at the DS1 Interface
The Alarm History screen reports DS1 statistics for the H2TU-C (
) and the H2TU-R (
) on a continuous basis. The types of alarms reported are described in
. Current alarms
are shown in reverse video.
Figure 20.
H2TU-C DS1 Alarm History Screen
P
SPACEBAR
ENTER
SPACEBAR
ENTER
N
P
L
Monitor
Performance
Event Log
Config
Inventory
Rlogon
Help
H2TU-C DS-1 Alarm History
------------------------------------------------------------------------------
Alarm
First
Last
Status
Count
LLOS
04/03/00 00:00
04/03/00 00:45
ALARM
12
LAIS
OK
0
DBER
04/03/00 00:37
04/03/00 00:45
OK
7
LOF
OK
0
Press: C(l)ear Alarm History
------------------------------------------------------------------------------
Press <Space> to cycle through
Interface
: H2TU-C DS-1
choices and <Enter> to view
Statistics :
Alarm History
ID: xxxx--xxxx--xxxx--xxxx
04/15/00 12:30:01
H2TU-C
System: Alarm