18.5
Power.
You can set the Power option to Disable or Enable. The Power setting allows you to
disable or enable line powering of the remote unit over the HDSL pair. The default is Enable.
1
Press <P> in the System Settings menu.
The Power option changes to the next available setting.
2
Repeat this process until the desired setting appears next to the Power option name in the menu.
18.6
ES Alarm Thres.
You can set the ES Alarm Thres (threshold) to a count of 17 or 170 seconds. This
setting causes the Status LED to flash red when the alarm threshold count has been exceeded. You
can also set the alarm threshold count to None. The default is None.
1
Press <R> in the System Settings menu.
The ES Alarm Thres option changes to the next available setting.
2
Repeat this process until the desired setting appears next to the ES Alarm Thres option name in
the menu.
18.7
Loopback Timeout (LBTO).
The Loopback Timeout can be set to a count 20, 60 or 120 minutes.
You can also set the loopback timeout to NONE, which disables the automatic time-out cancellation
of all loopbacks. The default is 60.
1
Press <T> in the System Settings menu.
The Loopback Timeout option changes to the next available setting.
2
Repeat this process until the desired setting appears next to the Loopback Timeout option name
in the menu.
18.8
HRU DS1 Code.
The HRU DS1 Code can be set to Auto, B8ZS or AMI. The default is AMI.
1
Press <D> in the System Settings menu.
The HRU DS1 Code option changes to the next available setting.
2
Repeat this process until the desired setting appears next to the HRU DS1 Code option name in
the menu.
18.9
DS0 Chan Slots.
The DS0 Chan (channel) Slots option can be set to ALT (alternating) or CONT
(contiguous). If the DS0 Chan Slots setting is ALT, customer data is transported on alternating
sequential timeslots 1, 3, 5...23 (timeslots 2, 4, 6...24 are not used). If the DS0 Chan Slots setting is
CONT, customer data is transported on contiguous sequential timeslots 1,2,3...12 (timeslots 13
through 24 are not used). The default is CONT.
1
Press <C> in the System Settings menu.
The DS0 Chan Slots option changes to the next available setting.
2
Repeat this process until the desired setting appears next to the DS0 Chan Slots option name in
the menu.
18.9.1
Data Applications.
ALT is the recommended setting for data applications. This setting prevents
ones density violations from occurring when installed in D4 channel banks configured for AMI. Use
of CONT may allow ones density violations to occur, resulting in possible interference to all 24 DS0
time slots and possible loss of frame sync. This also initiates a Multiplexer Out of Sync (MOOS)
condition with loss of customer data in all 24 DS0 time slots, until frame sync is re-acquired.
18.9.2
Voice Applications.
CONT is the recommended setting for voice channels or with D4 channel
banks configured for B8ZS.