![PairGain HIGAIN HLU-232 Manual Download Page 57](http://html1.mh-extra.com/html/pairgain/higain-hlu-232/higain-hlu-232_manual_3302940057.webp)
Section 150-232-100
Revision 01
Page 57
TABLE 17. HLU-232 A1LB TEST PROCEDURES (CONTINUED)
Step
Action
5
Using the following codes, a network tester can activate loopbacks NLOC or NREM or SMJK (if enabled)
shown in Figure 19. A customer tester can activate loopbacks CLOC or CREM.
ADDRESSABLE 1 (A1LB) REPEATER LOOPBACK COMMANDS
ARMING or NI LPBK (in-band)
Arming code
11000 11000 ...
ARMING or NI LPBK
(ESF Data Link)
Arming code
1111(F)*1111(F)0100(4)1000(8)
IR LPDN or DISARM (in-band)
Disarming code
11100 11100 ...
DISARM (ESF Data Link)
Disarming code
1111(F)1111(F)0010(2)0100(4)
IOR LPBK (NLOC & CREM 231
errors)
HLU Loop up
1101(D)0011(3)1101(D)0011(3)
ILR-1 LPBK
(NDU1 & CDU1 10 bit errors)
DOUBLER-1 Loop up
1100(C)0111(7)0100(4)0001(1)
ILR-20 LPBK
(NDU2 & CDU2 200 bit errors)
DOUBLER-2 Loop up
1100(C)0111(7)0101(5)0100(4)
ILR-2 LPBK
(NREM & CLOC 20 bit errors)
HRU Loop up
1100(C)0111(7)0100(4)0010(2)
IR LPDN
Loop down (HLU or HRU)
1001(9)0011(3)1001(9)0011(3)
IR QUERY LPBK
Query loopback
1101(D)0101(5)1101(D)0101(5)
IR ALTERNATE QUERY LPBK
Alternate Query loopback
1101(D)0101(5)1110(E)1010(A)
TIME-OUT OVERRIDE
Loopback Time-out Override
1101(D)0101(5)1101(D)0110(6)
FAR END NI ACTIVATE
Unblock AIS & pass 2 in 5
1101(C)0101(5)0101(5)0100(4)
IOR POWER DOWN (HLU)
Removes HDSL line power
0110(6)0111(7)0110(6)0111(7)
Note: The left most bit arrives first in all sequences. The detection algorithm functions reliably with a
random 10
-3
Bit Error Ratio (BER) on the facility. The IOR POWER DOWN code must remain present for
the duration of the power down mode. When this code is removed, the HiGain system returns to its
normal unlooped and unarmed state. *This is the HEX number for the 16-bit binary code.
6
After testing is complete, send the universal loopdown [IR (Intelligent Repeater) LPDN] code if the system
is to loopdown but remain ARMED. Send the disarm code 11100 if all the equipment is to be looped
down, disarmed and returned to normal operation. Note that the ARMED mode has an automatic time-out
of 120 minutes.
7
All of the above loopbacks can also be initiated from the front panel of the HLU-232 List 1D with the MODE
and SEL buttons (Section C Paragraph 3.10).