System Configuration
UTU-712 and ETU-762 List 1
May 10, 1999
29
Config Menu Options
Type
at the console screen (
to display the Config menu (
lists the Config menu
options and the order of system configuration.
Figure 18.
Console Screen Config Menu
Observe the following when configuring a system:
•
Configure settings in the order specified in
. The System Settings must be configured before the LTU
and NTU Interface settings. Changing System Settings can clear values configured in LTU and NTU Interface
settings.
•
When using a UTU as an LTU, change the Local Unit Role for the unit using the Config, System Settings
menu. Note that changing the Local Unit Role of a UTU causes the unit to reset and the LEDs to cycle.
•
When the HDSL units are reset or cycle power, the date field is saved but the time field is not saved. Set the
time using the Config Date and Time display. When the HDSL units are turned off and left off for a longer
period of time (more than 24 hours, for example), set both the date and time using the Config Date and Time
display since neither value was saved.
Table 14.
Config Menu Options and Recommended Order of System Configuration
Use this Option
To:
See page:
Terminal Settings
Select the best viewing mode for the console screen.
Date and Time
Set the system date and time.
Password
Set or change the system password.
Circuit ID
Assign a circuit ID.
System Settings
Select and configure system-wide operating parameters.
LTU and NTU Interface
Select and configure LTU/NTU-specific operating parameters.
Alarms
Enable or disable alarms and to select alarm severity.
and
Set to Factory Dflts
Reset all operating parameters to factory settings.
&