![PairGain HiGain-ETSI RS UTU 712 Manual Download Page 35](http://html1.mh-extra.com/html/pairgain/higain-etsi-rs-utu-712/higain-etsi-rs-utu-712_manual_3307695035.webp)
700-712-100-01, Revision 01
System Configuration
UTU-712 and ETU-762 List 1
May 10, 1999
27
R
EADING
AND
N
AVIGATING
M
ENUS
The menu and status bars appear on all console screens. The information on the rest of the screen varies depending
on the function of the menu or screen.
The menu bar displays the name of each menu. Choosing Monitor, History, or Config from the menu bar drops
down a menu of available options. When selected, all options on the Monitor drop-down menu, and the Alarm
option on the Config drop-down menu, display drop-down submenus.
The status bar at the bottom of the screen displays the circuit ID, the current date and time, unit type, and current
system information. Select Config from the console screen menu bar to enter or change the circuit ID and the
current date and time. The items described in
correspond to the numbers in
.
Figure 17.
Items in Console Screen Status Bar
Table 12.
Console Screen Status Bar Displays
Item
Field
Description
1
Circuit ID
Shows the user-selected name for the circuit (such as customer name).
2
Date and time
Today's date in dd/mm/yy format. Today's time in 24-hour format.
3
Local unit role
Either LTU or NTU.
4
System information
Displays the current system status. The system information field shows one of
the following:
• Loop down - At least one configured HDSL channel is down, either due to
restart, or startup not completing.
• Alarm - A major alarm condition is currently active in the system. In the case
of a loopback bringing the loop down, LOSW alarms will be ignored.
• Loopback - The system is in a diagnostic loopback configuration.
• Update - Circuit-wide provisioning is in progress.
• Normal - All configured HDS
• L channels are up in the circuit, no alarms are present, and provisioning is
complete.
1
2
3
4