PairGain FLC-703 Manual Download Page 10

Subscriber Drop Testing

 

 363-703-131-01, Revision 01

6

July 30, 1999

 FLC-703 List 3A

 

S

UBSCRIBER

 D

ROP

 T

ESTING

For PG-Flex subscriber drop testing from the CO, select and connect any subscriber drop to a metallic test pair at 
the RT. PG-Flex extends this connection to the COT where it can be switched onto the test access bus or to the 
corresponding subscriber line on the COT channel card.

Activate test access through the RS-232 maintenance port located on the front of the COT Line Unit using an 
ASCII terminal.

Table 1 on page 2

 provides PG-Flex system troubleshooting procedures based on indications displayed by the 

FLC-703 Channel Unit front panel LEDs or customer reported problems.

Indication

Problem

Action

FAULT 
LED On

The FLC-703 
processor has 
detected a fault.

Remove and re-insert the CU. If the FAULT LED does not extinguish, replace the CU.

Troubleshooting based on customer-originated trouble reports

No dial 
tone, can 
not dial

faulty RT or 
COT CU

facility 
short/open

CO switch 
problem

1

Lift the subscriber pair at the network interface. If dial tone is present and you can place a call, 
refer the problem to the customer per local practice.

2

If you cannot hear dial tone or place a call at the network interface (with the subscriber pair 
lifted), check for dial tone at the RT. If dial tone is present, check the pair between the RT and 
the network interface. If no dial tone is present, replace the RT CU.

3

If the problem still exists, re-insert the original RT CU and replace the COT CU. Test for 
operation.

4

If the problem still exists, refer the problem to the CO switch.

Phone 
does not 
ring

high-resistance 
subscriber line 
short

faulty RT or CO 
CU

loop length too 
long

1

Lift the subscriber pair at the network interface. If ringing is present, refer the problem to the 
customer per local practice.

2

If ringing is not present, check for ringing at the RT. If ringing is present, check the pair between 
the RT and the network interface. If no ringing is present, replace the RT CU. If ringing is still 
not present, check a circuit on another CU. If ringing is still not present, replace the LU.

3

If ringing is still not present at the RT, re-insert the original CU and LU. Test for ringing at the 
COT.

4

Test for ringing into the COT from the CO switch. If no ringing is present, refer the trouble to 
the CO switch. If ringing is present, replace the COT CU. Test again for ringing at the network 
interface. If ringing is still not present, contact PairGain technical assistance (see 

“Product 

Support” on Inside back cover

).

5

Verify the resistance of the copper loop between the RT Enclosure and the network interface is 
less than 530 

.

Phone 
does not 
stop 
ringing

faulty 
subscriber 
instrument

faulty RT CU

loop length too 
long

1

Test for ring trip at the network interface. If the ringing is tripped, refer the trouble to the 
customer per local practice.

2

If the ringing is not tripped, test for tripping at the RT. If ring trip does occur, check the loop for 
excessive length. If ring trip does not occur, replace the RT CU. If ring trip still does not occur, 
contact PairGain technical assistance (see 

“Product Support” Inside back cover

).

3

Verify the resistance of the copper loop between the RT Enclosure and the network interface is 
less than 530 

.

Can not 
hear, Can 
not be 
heard

subscriber 
problem

faulty RT or 
COT Channel 
Unit (CU)

1

Lift the subscriber line at the network interface and check the signal level. If correct, refer 
trouble to the customer per local practice.

2

2 If the level is too low, check the level at the RT. If the level is correct at the RT, check the pair 
between the RT and the network interface. If the level is too low at the RT, replace the RT CU.

3

3 If the level is still too low, re-insert the original RT CU.

4

4 Check the level at the COT coming from the CO switch. If it is correct, replace the COT CU. If 
it is not correct, refer the problem to the CO regarding the switch.

5

5 If the level is still not correct, re-insert the original COT CU. Contact PairGain technical 
assistance (see 

“Product Support” Inside back cover

).

Summary of Contents for FLC-703

Page 1: ...NEL UNIT PAIRGAIN TECHNOLOGIES INC ENGINEERING PLANT SERIES TECHNICAL PRACTICE SECTION 363 703 131 01 Model List Number Part Number CLEI Code FLC 703 3A 150 1303 31 VACHCDVC PairGain FLC 703 CHAN UNIT...

Page 2: ...in this document is company private to PairGain Technologies Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the written consent of PairGain Other product...

Page 3: ...ny and to PairGain Order replacement equipment if necessary Check the packing list to ensure complete and accurate shipment of each listed item If the shipment is short or irregular contact PairGain a...

Page 4: ...ons 3 FLC 703 Functions 4 Circuit Operation 4 Installation and Test ___________________________________________________________________ 5 Install the FLC 703 5 Verify Operation 5 Subscriber Drop Testi...

Page 5: ...s to the subscriber line connection through an optional metallic bypass pair Perform metallic bypass testing either manually or through the Pair Gain Test Controller PGTC Features of the FLC 703 COT C...

Page 6: ...and indications for the FLC 703 Channel Unit front panel LEDs Figure 1 FLC 703 Front Panel Table 1 Front Panel LEDs LEDs LEDs State Indicates ACTIVE 1 through 8 Solid green Channel is off hook Fast fl...

Page 7: ...nfiguration Electrical Characteristics Analog Impedance 900 Loop Length 100 CO switch to COT End to End Loss 2 5 dB 1 0 dB Channel Signature of Loop Start Lines Tip Ring Open Tip Ground 162 k 1 Ring G...

Page 8: ...signal from the RT FLC 703 generates an off hook signal to the Central Office CO to begin current flow CO sends dial tone FRC 753 recognizes dial pulses or Dual Tone Multi Frequency DTMF signaling fr...

Page 9: ...ized 1 Observe the front panel ACTIVE indicators are all OFF and the FAULT indicator is off no calls are in progress 2 Test circuits for loop start 1 Place an outgoing call for each subscriber circuit...

Page 10: ...RT and the network interface If no ringing is present replace the RT CU If ringing is still not present check a circuit on another CU If ringing is still not present replace the LU 3 If ringing is sti...

Page 11: ...l Area Signaling Services CO Central Office COT Central Office Terminal CU Channel Unit DTMF Dual Tone Multi Frequency LU Line Unit MLT Mechanized Loop Testing PCM Pulse Code Modulation PGTC Pair Gain...

Page 12: ......

Page 13: ...uthorization RMA number at 800 638 0031 Return the defective unit freight prepaid along with a brief description of the problem to PairGain Technologies Inc 14352 Franklin Avenue Tustin CA 92780 ATTN...

Page 14: ...Corporate Office 14402 Franklin Avenue Tustin CA 92780 Tel 714 832 9922 Fax 714 832 9924 For Technical Assistance 800 638 0031...

Reviews: