Installation and Turn-up
363-860-100-02, Revision 02
4
March 28, 2000
FRE-860, FRE-865, FRE-867, and FRE-868
I
NSTALLATION
AND
T
URN
-
UP
The installation of an RT Enclosure involves the following procedures:
•
mounting the RT Enclosure
•
wiring the RT Enclosure
•
turn-up and testing
•
closing the housing
R
EQUIRED
T
OOLS
AND
T
EST
E
QUIPMENT
•
216 Tool (can wrench)
•
flat-head screwdriver
•
insulated-handled needlenose pliers
Be careful when working with telephone circuits. Dangerous voltages can be present. It is
unsafe to install telephone wiring during a lightning storm.
All wiring external to the product should follow the local wiring codes.
Always treat the HDSL pairs as if they were live with high voltage present. Use caution when
installing HDSL pairs that are already connected to a COLU, because dangerous voltages are
present on the HDSL pairs.
The COLU, unless previously disabled by means of Craft provisioning, periodically attempts to
power up the RT Enclosure by ap/-130 Vdc to the HDSL pairs.