Overview
150-431-115-01, Revision 01
8
September 22, 1998
HLU-431 List 1E
HLU-431 List 1E Card Connector
shows the card-edge connectors on the HLU-431. Active pins are highlighted in black.
Figure 2.
HLU-431 List 1E Card-Edge Connector
Network Management Control Bus
The HLU-431 List 1E provides a Network Management Control Bus on pin 46 of the card-edge connector. This
allows the various PairGain Management System protocols to manage the HLU through the HMU-319 HiGain
Management Unit. Whenever the HLU-431 is under management, the
MNGD
message displays periodically on the
HLU-431 front panel display.
Fuse Alarm
Pin 25 on the card-edge connector is a Fuse Alarm that is driven to -48V through a 1000
Ω
resistor whenever the
onboard fuse opens.
Some HLU-431 features are affected when it is under management. Consult the management
unit practice for further information.
27
25
23
21
19
17
15
13
11
9
7
3
5
1
ALARM
MANAGEMENT
DS1TIP
DS1 RING
HDSL2 RING1
HDSL2TIP 1
48V
FUSE ALARM
CIRCUIT GND
DS1 RING1
HDSL1 RING
XMT
RCV
HDSL1TIP
DS1TIP1
CASSIS GND*
FACORY BURN-IN
(DO NOT USE)
28
26
24
22
20
18
16
14
12
10
8
4
6
2
55
53
51
49
47
45
43
41
39
37
35
32
31
56
54
52
50
48
46
44
42
40
38
36
34
30
33
29
* Chassis GND may be tied to earth GND per local practice.