Revision 01
Section 350-
431
-
114
-01
HLU-
431
List
1D
Page 7
Default Settings
To return the system options back to the original factory default settings:
1
Press the SEL button until the DFLT NO message appears.
2
Press the SEL button again and DFLT YES displays indicating the
factory default values are now in effect.
To terminate the DFLT mode without setting the factory default values, press
the MODE button or do nothing for 30 seconds.
Using the Craft port
The Craft port, a 9-pin RS-232 connector, on the HLU-
431
front panel allows
you to use a standard RS-232 cable to connect your system to a dumb terminal
or PC running a terminal emulation program. Once connected you can access
the maintenance, provisioning, and performance screens.
To provision the HLU-
431
through the Craft port:
1
Configure the dumb terminal to the following communication settings:
•
1200 to 9600 baud (9600 baud is recommended)
•
Parity: NONE
•
8 data bits
•
1 stop bit
•
Hardware Flow Control set to NONE
•
VT Terminal Emulation
2
Use a serial cable to connect the RS-232 COM port on the dumb terminal
to the HLU-
431
front panel Craft port.
If using the Microsoft Windows terminal emulation program,
from the Settings, Terminal Preference menu, deselect
Show Scroll Bars and Use Function, Arrow, and Ctrl Keys for
Windows.