PairGain 150-1504-14 Quick Installation Manual Download Page 18

Section 350-

431

-

114

-01

Revision 01

Page 16

HLU-

431

 List 

1D

Specifications

Maximum Power Consumption

14 Watts (without Doubler); 23 Watts (with Doubler).

Maximum Heat Dissipation

6 Watts (without Doubler); 8 Watts (with Doubler).

Mounting

STS, high-density slot431

Dimensions

Height:

5.6

" (

14

 c.m.)

Width:

1.4

" (

3.5

 c.m.)

Depth:

5.6

" (

14

 c.m.)

Weight: 1 lb. 2 oz.

Documentation

The HLU-

431

 List 

1D

 has a complete technical practice that you can 

download from the PairGain Technical Manuals Web page at: 
www.pairgain.com. A password is required. If you do not have a password, 
contact your PairGain sales representative.

If you have any comments on any PairGain documentation, send mail to 
[email protected].  Type the product name and the 
section number of the document in the subject area of the email message.

Technical Support

PairGain Technical Assistance is available 24-hours-a-day, 7-days-a-week by 
contacting PairGain Customer Service Engineering group at: 

Telephone:  (800) 638-0031 or (714) 832-9922 

Fax:  (714) 832-9924

During normal business hours (8:00 AM to 5:00 PM, Pacific Time, Monday 
- Friday, excluding holidays), technical assistance calls are normally 
answered directly by a Customer Service Engineer.  At other times, a request 
for technical assistance is handled by an on-duty Customer Service Engineer 
through a callback process.  This process normally results in a callback within 
30 minutes of initiating the request.

Summary of Contents for 150-1504-14

Page 1: ...QUICK INSTALLATION GUIDE PAIRGAIN TECHNOLOGIES INC SECTION 350 431 114 01 Revision history of this guide Revision 01 January 27 1998 A Initial Release Model List Part Number CLEI Code HLU 431 1D 150 1...

Page 2: ...Messages 14 Specifications 16 Documentation 16 Technical Support 16 Bulletin Board Services 17 Copyright 1998 PairGain Technologies Inc PairGain and HiGain are registered trademarks of PairGain Techn...

Page 3: ...nit to provide a complete HiGain High bit rate Digital Subscriber Line HDSL system This guide addresses HLU 431 List 1D operation when used with and without doublers For applications without doublers...

Page 4: ...wn in the Card Edge Connectors on page 4 HRE 420 Single Slot HRE 422 Dual Slot HRE 427 Seven Slot HRE 450 Single Slot Outdoor HRE 454 Four Slot Outdoor Status LED States State Description Green Normal...

Page 5: ...nstallation Upon receipt of the equipment visually inspect it for signs of damage If the equipment has been damaged in transit immediately report the extent of damage to the transportation company and...

Page 6: ...Section 350 431 114 01 Revision 01 Page 4 HLU 431 List 1D Card Edge Connectors The HLU 431 card edge connector pinouts are shown below...

Page 7: ...ng the Line Unit To install the HLU 431 into a shelf slide the unit into the shelf card guides for the desired slot then push the unit in until it is entirely within the card guide and the retaining l...

Page 8: ...via buttons on the front panel or through the RS 232 interface They are retained if shelf power is lost or if the HLU 431 List 1D is unplugged The System Options table on page 8 lists the system optio...

Page 9: ...use a standard RS 232 cable to connect your system to a dumb terminal or PC running a terminal emulation program Once connected you can access the maintenance provisioning and performance screens To...

Page 10: ...equalizer to DSX 1 for 533 655 feet ZBTS ON Tells HiGain that the ESF frame is operating in its ZBTSI mode OFF Tells HiGain that the ESF frame is operating in its normal non ZBTSI mode ESAL 17 Activat...

Page 11: ...res the HiGain system to respond to the generic 3 4 5 6 in 7 in band loopback codes A1LB and A2LB Configures the HiGain system to respond to the Teltrend addressable repeater in band loopback codes A3...

Page 12: ...it the AIS signal at both the HLU and HRU T1 output ports when both of the HDSL loops are not in sync LOSW 1LP Causes HiGain to transmit the AIS signal at both the HLU and HRU T1 output ports when eit...

Page 13: ...Signal No signal at the HLU 431 List 1D local T1 interface RLOS Remote Loss of Signal No signal at the HRU remote T1 interface LOSW1 or LOSW2 Loss of Sync Word 1 or 2 HDSL loop 1 or 2 has lost sync H1...

Page 14: ...he CBA initiated by upstream in band codes or from the maintenance terminal NLOC Network Local Loopback Loopback at HLU local toward the CBA initiated by upstream in band codes or from the maintenance...

Page 15: ...in band codes or the maintenance terminal NDU2 Network Doubler 2 Loopback The loopback at doubler 2 toward the CBA initiated by in band codes or the maintenance terminal CDU1 Customer Doubler 1 Loopb...

Page 16: ...2nd Doubler and HRU transceivers are trying to establish contact with each other on loops 1 or 2 of span 3 ACQ 1 or 2 Acquisition 1 or Acquisition 2 The HLU and HRU or 1st Doubler multiplexers are try...

Page 17: ...uestionable VER HLU Software Version Displays during the System Settings review mode Depress the MODE button for 3 seconds to view the saoftware version LIST 0xL HLU s List Displayed during System Set...

Page 18: ...y comments on any PairGain documentation send mail to technical_publications pairgain com Type the product name and the section number of the document in the subject area of the email message Technica...

Page 19: ...n board system for obtaining current information on PairGain products product troubleshooting tips and aids accessing helpful utilities and for posting requests or questions This system is available 2...

Page 20: ......

Reviews: