150-388-105-05, Revision 05
Appendix A - Specifications
HLU-388 List 5
March 25, 2000
57
through
show power parameters for two doubler line-powered circuits on 9 kft, 26 AWG loops.
shows power parameters for three doubler line-powered circuits or four doubler locally-powered circuits
on 9 kft, 26 AWG loops.
Table 22.
HLU-388 Power Parameters—Two Doublers (HDU-451 List 3, 4, 3B, or 4B)
HRU Model No.
HRU CPE
Power
42.5 Vdc Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 Vdc Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-402
N/A (OFF)
28.3
31.1
8.3
9.1
665
732
HRU-411
OFF
28.1
30.9
8.2
9.0
661
727
Table 23.
HLU-388 Power Parameters—Two Doublers (HDU-439 or HDU-437 Lists 1 and 1B)
HRU Model No.
HRU CPE
Power
42.5 Vdc Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 Vdc Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3, 4
OFF
30.3
33.3
8.0
8.8
713
784
HRU-412 List 6, 7, 8
OFF
28.1
30.9
7.7
8.5
660
726
HRU-402
N/A (OFF)
24.8
27.3
7.2
7.9
584
642
HRU-411
OFF
27.7
30.5
7.5
8.3
652
717
Table 24.
HLU-388 Power Parameters—Two Doublers (HDU-409 List 2)
HRU Model No.
HRU CPE
Power
42.5 Vdc Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 Vdc Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3,4
ON
24.4
26.8
7.2
7.9
575
633
HRU-412 List 1, 2, 3,4
OFF
22.1
24.3
6.8
7.5
520
572
HRU-412 List 6, 7, 8
ON
25.9
28.5
7.4
8.1
609
670
HRU-412 List 6, 7, 8
OFF
20.2
22.2
6.4
7.0
476
524
HRU-402
N/A (OFF)
17.4
19.1
7.1
7.8
410
451
HRU-411
OFF
16.5
18.2
6.0
6.6
389
428
Table 25.
HLU-388 Power Parameters—Three and Four Doublers (HDU-409 List 2)
HRU Model No.
HRU CPE
Power
42.5 Vdc Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 Vdc Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-402, 3-doubler,
line-powered
N/A (OFF)
22.9
25.2
8.1
8.9
539
593
HRU-402, 4-doubler,
local power
N/A (OFF)
23.7
26.1
8.0
8.8
557
613