![PairGain 150-1140-42 Manual Download Page 50](http://html1.mh-extra.com/html/pairgain/150-1140-42/150-1140-42_manual_747317050.webp)
Revision 01
December 22, 1997
150-319-142-01
44
PairGain Engineering - Plant Series
HLU-319 List 4B
CODE
Line Code: AMI, B8ZS
The line code that HLU-319 List 4B is
receiving at its DSX-1 interface, if the
DS1 option is set to Auto. Otherwise, it
mimics either of the other two DS1 line
code settings, AMI or B8ZS. Displayed
during System Settings review mode.
LOSW
Loss of Sync Word
Indicates that one of the HDSL loops
has lost sync. Causes a minor alarm.
LLOS
Local Loss of Signal
Indicates that no signal is detected at
the DSX-1 input to the HLU-319 List 4B.
Causes a minor alarm.
RLOS
Remote Loss of Signal
Indicates that no signal is detected at
the DSX-1 input to the HRU-412 List 8B.
Causes a minor alarm.
DS1
DS1 BPV Errors
Indicates that the number of BPVs at the
HLU-319 List 4B or HRU-412 List 8B T1
inputs have exceeded the 24-hour ES
threshold. Causes a minor alarm.
DS0
DS0 Blocked Channels
Indicates status of DS0 blocked
channels. NONE indicates no channels
are blocked. BLK indicates some
channels are blocked.
MAL1
Margin Alarm Loop 1
The margin on HDSL loop 1 has
dropped below the threshold (0 to
15 dB) set by the user.
MAL2
Margin Alarm Loop 2
The margin on HDSL loop 2 has
dropped below the threshold (0 to
15 dB) set by the user.
MNGD
Managed
The HLU-319 List 4B is under control of
the HMU-319 List 5B network
management unit. In this state, the Craft
port on the HLU-319 List 4B front panel
is inoperative.
Table 7.
HLU-319 List 4B Four-Character Front Panel Messages (Continued)
Message
Full Name
Description