![PairGain 150-1140-42 Manual Download Page 31](http://html1.mh-extra.com/html/pairgain/150-1140-42/150-1140-42_manual_747317031.webp)
150-319-142-01
December 22, 1997
Revision 01
HLU-319 List 4B
PairGain Engineering - Plant Series
25
L
DIS
Configures the HiGain system to ignore the (2-in-5) in-band
SmartJack loopback command.
ENA*
Enables the HiGain system to recognize the (2-in-5) in-band
SmartJack loopback command.
S
GNLB*
Configures the HiGain system to respond to the generic
(3/4/5/6-in-7) in-band loopback codes.
(S
cont)
A1LB and A2LB
Configures the HiGain system to respond to the Teltrend
addressable repeater in-band loopback codes.
A3LB
Configures the HiGain system to respond to the Wescom
addressable repeater in-band loopback codes.
A4LB
Configures the HiGain system to respond to the Wescom
Mod 1 addressable repeater in-band loopback codes.
A5LB
Configures the HiGain system to respond to the Teltrend
Mod 1 addressable repeater in-band loopback codes.
P
DIS
Disables powering to the HRU-412 List 8B and doubler.
ENA*
Enables powering to the HRU-412 List 8B and doubler.
Z
ON
Tells the HiGain system that the ESF frame is operating in its
Zero Byte Time Slot Interface (ZBTSI) mode.
OFF*
Tells the HiGain system that the ESF frame is operating in its
normal non-ZBTSI mode.
R
17
Flashes the red Status LED when 17 Errored Seconds (ES)
(17 HDSL cyclic redundancy check (CRC) errors on either
HDSL loop or a total of 17 BPVs on DSX-1) occur within a
24 hour period.
170
Flashes the red Status LED when 170 ES (170 HDSL CRC
errors on either HDSL loop or a total of 170 BPVs on DSX-1)
occur within a 24 hour period.
NONE*
Prevents generation of a minor alarm due to excessive
errored seconds.
Table 3.
HLU-319 List 4B System Setting Menu Options (Continued)
Option
Parameter
Description
* Indicates HLU-319 List 4B factory (default) settings. (Continued)