12
MidiHeat EHD
MA45-33 GB translated from the original language of the instruction (SE)
ENGLISH
1
4
2
3
5
5
11
12
7
6
8
10
10
9
13
Art.no.
Rev.no.
Scale
Designed by:
Approved by:
Revised by: Date
Drawn by: Date
Drawing number
Assembly drawing no.
Surface treatment
part of ISO 2768-1
The tolerance class in accordance with this
E
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
ASA 2016-10-03
MidiHeat master/slave
M12589 0
Th
is
d
oc
um
en
t a
nd
it
s
co
nt
en
ts
a
re
th
e
ex
cl
us
iv
e
pr
op
er
ty
o
f P
ah
lé
ns
a
nd
m
ay
n
ot
b
e
co
pi
ed
,
re
pr
od
uc
ed
, t
ra
ns
m
itt
ed
o
r c
om
m
un
ic
at
ed
to
a
th
ird
pa
rty
, o
r u
se
d
fo
r a
ny
p
ur
po
se
w
ith
ou
t w
rit
te
n
pe
rm
is
si
on
.
Art.no.
Rev.no.
Scale
Designed by:
Approved by:
Revised by: Date
Drawn by: Date
Drawing number
Assembly drawing no.
Surface treatment
part of ISO 2768-1
The tolerance class in accordance with this
E
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
ASA 2016-10-03
MidiHeat master/slave
M12589 0
Th
is
d
oc
um
en
t a
nd
it
s
co
nt
en
ts
a
re
th
e
ex
cl
us
iv
e
pr
op
er
ty
o
f P
ah
lé
ns
a
nd
m
ay
n
ot
b
e
co
pi
ed
,
re
pr
od
uc
ed
, t
ra
ns
m
itt
ed
o
r c
om
m
un
ic
at
ed
to
a
th
ird
pa
rty
, o
r u
se
d
fo
r a
ny
p
ur
po
se
w
ith
ou
t w
rit
te
n
pe
rm
is
si
on
.
Installation
Piping must be performed before wiring.
Place the heater so that the front and top parts can be opened. Install connectors so that the heater can be easily moved for
inspection, cleaning and servicing
A check valve should be installed AFTER the heater and a shutoff valve BEFORE the heater, so that servicing of the heater can
be performed without emptying the swimming pool.
A bypass connection should be installed and adjusted so that the recommended flow through the heater can be achieved.
If several (2-10) MidiHeat devices are connected in parallel, each Midi Heat should have its own by-pass connection for easy
servicing.
Fix the heater on a flat horizontal floor/foundation with a screw/bolt through four Ø9 mm holes in the bottom.
Piping layout
Plug the heater into the pool system according to the flowchart below. The outlet may not be connected to any type of crane or
connections other
than those stated here.
The heater is equipped with connections G2¾” for binding PVC pipes with outside diameter Ø63 mm.
Note! Do not install a shutoff valve between the heater and the swimming pool (install check valve instead). Dosing of chlorine,
acid or similar must always be done AFTER the heater.
1. Skimmer
2. Main drain
3. Inlet
4. JetSwim
5. Light
6. Pump
7. Filter
8. MidiHeat
9. Check valve
10. Drain outlet
11. Valve - bypass
12. Valve - suspension
Fig. 2
Fig. 3.
Example of several
Midi Heat devices
Drain Drain
Technical data
Max. load
2 bar (0.2 MPa)
Max. flow
300 l/min
Min. flow
170 l/min
Ambient temperature
+5ºC till +40ºC
General information
Follow these instructions concerning water quality:
Free chlorine:
0.5-1.5 mg/liter (ppm)
Combined chlorine:
0-0.5 mg/liter (ppm)
Total chlorine:
0.5-2.0 mg/liter (ppm)
Chloride (salt) content: —
pH-value:
7.2-7.6
Alkalinity:
60-120 mg/liter (ppm)
Calcium hardness:
100-300 mg/liter (ppm)