Heat pump Calidi XP

M

A

20-23 GB 

T

ranslation of the original instructions (Swedish)

Operation

If a power failure occurs during operation, the heat pump restarts automatically when the power is restored.

Display

No buttons can be used if the display is locked.

When the heat pump is turned on, the display indicates the pool temperature or a possible error code.

If the display is not used for 30 seconds, it turns o昀昀 (screen lock).

Putting heat pump into operation

Note!

 Pool system CIRCULATION PUMP should always BE STARTED BEFORE THE HEAT PUMP.

Do the following:

1.  Check that the heat pump and pipe connections are installed according to the pipe laying diagram.
2.  Check the installation against the wiring diagram and that grounding is correct.
3. 

Check that the heat pump operating switch is turned o昀昀.

4.  Start the pool system circulation pump.
5.  Check that there are no water leaks in the system.
6.  Check that the pump air inlet and outlet are not blocked.
7.  Turn on the operating switch for the heat pump (symbols in display do not light up yet).
8. 

Start the heat pump by pressing the “Lock up” button for 3 seconds and then the On/O昀昀 button. (Symbols in display light up.)

9.  Check the heat pump temperature setting / Set the appropriate temperature, see below.
10. 

Select mode, see “Mode selection” below. (Full power is the default mode.)

11.  Check that no unusual noises are coming from the heat pump when it is in operation.

Setting the desired water temperature

Setting the water temperature, 18 – 40° can be done regardless of whether the heat pump is operating or not.

Press “Lock up” button for 3 seconds and then press ▲ or ▼ to set the required temperature. 

In order to check the settings, press ▲ or ▼. The desired temperature is displayed blinking for a few seconds.

After the required pool temperature is obtained, the heat pump regularly checks the temperature and when it falls below the set 
value, heating will start again. 

Example:

 The set temperature is 26° C. The heat pump then stops at 26.4 ° and restarts at 25.4°.  

When the temperature reaches 25 ° the heat pump operates between 20–80% capacity until the temperature reaches 26.4°.

Controlling and adjusting the water 昀氀ow

• 

Adjust to the recommended water 昀氀ow through the heat pump by means of valves in the bypass kit (or another pipe laying

 

pattern).

•  Let the heat pump run for at least for 5 minutes.

•  Check parameters for incoming water temperature and outgoing water temperature. 

The di昀昀erence for optimal e昀케ciency should be between 1– 3°C.

 

Open the bypass valve in order to increase the di昀昀erence or the throttle valve to reduce the di昀昀erence.

Mode selection

Heat pump always starts in the “Full power” mode, indicated by three bars in the symbol for e昀昀ect on the display.

Press the “eco” button to change the operation mode (indicated by two bars). 

NOTE!

 We recommend the “Full power” operating mode when starting the pool in the spring. The heat pump will then give full 

power to quickly heat up the pool. When the pool is heated to the desired temperature, “eco” operation is recommended. 

 

The heat pump then gives a maximum of up to 80% power. 

Button

Function

1. On/O昀昀

Working / Stand by

2. Unlock

Press 3 seconds to unlock 
(light) the display.
Press 3 seconds to lock the 

display (light turn o昀昀).

3. E昀昀ect

Full power or eco mode

4. Arrows

Setting the pool temperature

Heating capacity

shows in %

Temperature  
INLET

Incoming water

Power

Two bars = eco
Tree bars = full power

Temperature 
OUTLET

Outgoing water

Heating

Wi-Fi connection

Lights up when XP 
is in operation.

Summary of Contents for Calidi XP

Page 1: ...Copyright 2023 Pahl n AB Box 728 SE 194 27 Upplands V sby Sweden Tel 46 8 594 110 50 Fax 46 8 590 868 80 e mail info pahlen se www pahlen com Instruktion Calidi XP MA20 23 rev 4 2023...

Page 2: ...rift 7 Inst llning av nskad vattentemperatur 7 Kontroll och justering av vatten de 7 Val av driftl ge 7 Avfrostning 8 Underh ll 8 Vinterf rvaring 8 Fels kning 9 Felkoder 10 WiFi 11 SVENSKA Villkor f r...

Page 3: ...de st ngs v rmepumpen av och displayen visar felkod E3 V rmepumpen terstartar automatiskt n r det terg tt till det normala H g och L gtrycksvakt Skyddar kompressorn Tryckvakten k nner av trycket p k l...

Page 4: ...mm Vikt 49 kg 52 kg 63 kg 93 kg 120 kg K ldmedie R32 K ldmediem ngd 0 75 kg 0 9 kg 1 0 kg 2 0 kg 2 7 kg A Omgivningsf rh llande Luft 26 Vatten 26 Luftfuktighet 80 B Omgivningsf rh llande Luft 15 Vatte...

Page 5: ...talleras utomhus p en v l ventilerad plats f r att undvika tercirkulation av den kylda luften Det kr vs minst 300 mm fritt utrymme fr n v ggar buskage eller annat runt hela v rmepumpen f r att inte hi...

Page 6: ...ing kan beh va g ras f r r ren s att de inte belastar v rmepumpens anslutningar brytkraften kan skada v rme v xlaren All tdragning av unionskopplingarna till v rmepumpen b r endast ske med handkraft v...

Page 7: ...en Exempel inst lld temperatur r 26 C V rmepumpen stannar d vid 26 4 och terstartar vid 25 4 N r temperaturen n r 25 arbetar v rmepumpen mellan 20 80 kapacitet tills temperaturen n r 26 4 Kontroll och...

Page 8: ...era regelbundet bultar kablar och anslutningar St ng av v rmepumpen vid skv der G r ren v rmepumpens insug fr n eventuella l v barr och annat skr p som kan f rhindra cirkulationen Reng r v rmepumpen u...

Page 9: ...epumpens v rmev xlare Inget fel V rmepumpen startar ej Efter att inst lld pooltemperatur uppn tts stannar v rmepumpen och kontrollerar sedan att temperaturen sjunkit en grad Inget fel Den startar igen...

Page 10: ...sskyddsvarning Vatten och utomhustemperaturen understiger 2 C P0 Kommunikationsfel kontrollpanelen Kontakta installat ren P1 Temperatursensor f r ing ende poolvatten Kontakta installat ren P2 Temperat...

Page 11: ...m att rulla cirkeln med din ngertopp Eget angivet namn Indikation av v rmedrift Kapacitet visas i Aktuell temperatur i poolen Inst lld temperatur Timerfunktion Driftl ge V lj Full e ekt eller eco Star...

Page 12: ...Manual Copyright 2023 Pahl n AB Box 728 SE 194 27 Upplands V sby Sweden Tel 46 8 594 110 50 Fax 46 8 590 868 80 e mail info pahlen se www pahlen com User manual Calidi XP MA20 23 rev 4 2023...

Page 13: ...d 7 Setting the desired water temperature 7 Controlling and adjusting the water ow 7 Mode selection 7 Extra defrosting 8 Maintenance 8 Winter storage 8 Troubleshooting 9 Error codes 10 WiFi 11 ENGLISH...

Page 14: ...and the display shows E3 error code When the ow returns to normal the heat pump restarts automatically High and low pressure guard Protects compressors The pressure switch can detect the refrigerant c...

Page 15: ...52 kg 63 kg 93 kg 120 kg Refrigerant R32 Refrigerant quantity 0 75 kg 0 9 kg 1 0 kg 2 0 kg 2 7 kg A Ambient conditions Air 26 Water 26 Humidity 80 B Ambient conditions Air 15 Water 26 Humidity 70 Dat...

Page 16: ...order to avoid cold air recirculation It requires at least 300 mm clearance from the walls shrubbery or the like around the heat pump in order not to block air intake Note also that the pump requires...

Page 17: ...electrician in accordance with applicable regulations Installation must be preceded by installation of a residual current device and maintenance switch Never start the pump until all wiring and re ch...

Page 18: ...temperature In order to check the settings press or The desired temperature is displayed blinking for a few seconds After the required pool temperature is obtained the heat pump regularly checks the...

Page 19: ...check the bolts cables and connections Turn o the heat pump during thunderstorms Clean the heat pump s intake from any leaves pine needles and other dirt that can obstruct circulation Clean the exter...

Page 20: ...l not start After the set pool temperature is obtained heat pump stops and begins to check the temperature Nothing wrong It will start again when the controls detect a temperature drop by 1 C Restarti...

Page 21: ...l panel communication error Contact your installer P1 Temperature sensor for ingoing pool water Contact your installer P2 Temperature sensor for outgoing pool water Contact your installer P3 Temperatu...

Page 22: ...d device are as close as possible Reconnection When the WiFi password changes or the network con guration changes Press the On O button for 10 seconds The WiFi symbol blinks slowly for 60 seconds then...

Reviews: