Electric heater Aqua HL line
MA45-1
1E
ENGLISH
1. Skimmer
2. Main drain
3. Inlet
4. JetSwim
5. Light
6. Pump
7. Filter
8. Electric heater
9. Check valve
10. Drain
The electric heater must be installed horizontally as shown on the drawing, so that it is always full of water. The heater must
never be started or left switched on unless it is completely full of water (fire risk).
If the heater is positioned against combustible material, a fireproof panel or similar must be placed between the heater and
the wall.
The panel must extend 10 cm outside the outer dimensions of the heater.
Do not cover the heater.
Dosage of chlorine, acid or similar, must be done after the heater to avoid corrosion.
The warranty is void if the heater has been incorrectly installed or used.
Important! The standard heater must not be used in aggressive water, salt water or for pools with a chlorinator/salt generator.
In such circumstances an Electric heater Aqua HL line titanium is required.
“Persons with limited physical or mental capacity (including children) must not use the device without instructions on how to use
it safely”, according to IEC 60335-1.
Technical data
Dimensions
Max temperature:
45°C
Max pressure:
2 bar
Min flow:
90 l/min
The product is intended for the following
water values:
Chlorine content:
max 3 mg/l (ppm)
pH-value:
7.2–7.6
Alkalinity:
60–120 mg/l (ppm)
Calcium hardness:
100–300 mg/l (ppm)
Aqua HL line
Chloride (salt) content: max 250 mg/l
Aqua HL line Titan
Chloride (salt) content: max 35 000 mg/l
Outside these values, the product warranty is void.
Pipe installation
The heater must be installed in the return line to the pool AFTER the filter; see the installation drawing.
Do not install a shut-off valve between the heater and the pool. If a valve is required, install a check valve. If there is a risk of
freezing where the heater is located, the installation must allow all water to be drained from the heater.
The outlet of the electric heater must not be connected to any tap or coupling other than in accordance with the installation
drawing.