Aqua HL
3-phase 400V
C2
C1
RC1
L1
L1
BK 2,5mm²
BK 2,5mm²
BR 2,5mm²
BR 2,5mm²
WH 2,5mm²
WH 2,5mm²
YL/GN 2,5mm²
WH 0,75mm²
OR 0,75mm²
GR 0,75mm²
GN 0,75mm²
BK
0,75mm²
BU 0,75mm²
L2
L2
L3
L3
N
E10014-15
2019-12-18 ASA
3-phase
400V AC
+45°
J1
P1
P2
N 4
N 3
L1 2
L1 1
J3
J2
J4
L1
N
M
A1
A1
A2
A2
L1
L2
L3
M
F
F
F
S1
S
F1
(100mA)
F2
(2AT för L1)
BK
BU
12
ENGLISH
Electric heater Aqua HL
MA45-1
1 GB
Translation of the original instructions (Swedish)
Electrical Diagram
3-phase 400/415V AC
Flow switch
Temp.sensor
pool
Control
circuit board
Display
circuit
board
Overheating
limit control
External motor protection
External motor
protection
Heating element 3–15kW
1-phase
3-phase
The electrical installation work is done AFTER the plumbing has been installed. A permanently installed installation cable is
recommended.
If the circulation pump is fitted with a protective motor auxiliary relay, this must be connected to connection blocks P1 and P2;
refer to the schematic diagram for the respective voltage and number of phases. When the motor protector is engaged,
the circuit shall be closed with a floating-voltage change-over contact.
If no external motor protector is present, connection blocks P1 and P2 must be connected together (strapped).
Make sure that the connecting wire cannot come into contact with the hot parts of the element.
When the electrical installation is complete, the cover is place onto the connection box.
3-phase
400V AC
BK = black
BR = brown
BU = blue
GR = grey
GN = green
OR = orange
RD = red
WH = white
YL = yellow
Electrical installation
WARNING
•
The electrical installation must only be performed by an authorised electrician and in
accordance with national statutes and regulations.
•
The electrical installation shall be done via an all-pole circuit breaker, as well as a residual
current device indirectly via a contactor controlled from the pump’s electrical connection.
This will prevent the heater from starting without the water circulating.
•
The heater must be connected electrically according to the electrical diagram below.
Verify against the rating plate on the product.