background image

7. Clearing Blockages

Turn vacuum cleaner off and disconnect the power plug
from the power point.

The flexible hose can be disconnected from the vacuum
cleaner by rotating anti-clockwise and pulling away from
the machine. Remove any blockages found then
reconnect the hose. (Fig.7_1)

9. troubleshooting

www.pacvac.com

Support: 08 9479 1444

 

  note: Disconnect the power cord

 

  before maintenance, servicing and 

 

  troubleshooting.

fig.7_1

8.  technical Specification

Voltage: 

220-240V ~50Hz

Wattage: 

1300W (max)

Noise: 

<74 dB(A)

Capacity: 

15 litres

Filters: 

Foam pre-motor filter or HEPA filter 

 

 

Microfiltration cage

Cord length: 

18m

Weight: 

5.81kg (dependant on model)

Subject to technical change without notice.

8

9

10. Glide Parts Profile

1

x2

x4

x6

x2

x2

x6

x5

x2

2

3

4

5

6

7

8

9

10

37

40

38

35

34

32

33

31

30

27

23a

22

21

29

26

20

19

18

17

16

15

14

13

12

11

36

23a

24

25a

25b

28a

28b

37a

37b

37c

41

42

39

43

CD1501 BoM

no.  Part name 

Part no.

1.  Handle cover 

G103

2.  Handle base 

G105

3.  Top cover 

G107

4.  Exhaust filter 

G259

5.  Motor housing 

G256

6.  Noise insulation 

G254

7.  Latch 

G131B

8.  Middle base 

G115B

9.  Screw 

G10

10.  Noise insulation 

G255

11.  On/Off button 

G261/2

12.  Spring 

G435

13.  Screw 

G11

14.  Switch pedal 

G260

15.  Switch 

G261

16.  Screw 

G12

17.  2-hole stopple 

G17

18.  Power cord assy 

G108

19.  Screw 

G13

20.  Pedal for power cord  G262
21.  Screw 

G14

22.  Thermal cut-out 

G01A

23a. Right motor bracket 

G276R  

23b. Left motor bracket 

G276L

24.  Motor 

G118

25a. Motor gasket 

G253

25b. Motor housing gasket  G253B
26.  Air inlet grill 

G26B

27.  Screw 

G15

28a. Motor filter 

G522

28b. HEPA filter 

G288

Note: Part standard for Glide 

HEPA model or available as 

upgrade for standard Glide

29.  Cuff for air inlet grill 

G29

30.  Seal for SMS Filter 

G126

31.  Retainer for SMS Filter  G127B
32.  SMS filter 

G128

33.  Dustbag (Reuseable)  G129
34.  Main cannister 

G252

35.  Castor wheel 

G145

36.  Suction pedestal 

G138

37.  Hose assembly complete G32B
37a. Bent hand piece 

KC330

37b. Hose cuff hull 

KC300

37c. Hose cup ring 

KC310

38.  Wand 

KC909/2

39.  Floor Tool 

UA908W

40.  Crevice Tool 

KC911

41.  Dusting Brush 

KC910

42.  Upholstery tool 

KC912

43.  Disposable Paper Bags KC286

PRoBLeM: Vacuum Cleaner not working

Cause:

Power cord not firmly plugged into 
power point.

Solution:

Plug power cord into power point firmly.

Cause:

Vacuum cleaner not turned on.

Solution:

Press on/off button.

Cause:

Thermal protector shuts cleaner off due to 
high motor temperature.

Solution:

Turn main switch off and unplug the 
vacuum cleaner.  Ensure the filters are 
clean.  Inspect the wands, hose and floor 
tool and remove any blockages. After 30 
minutes the vacuum cleaner should be 
ready for use. If not contact Pacvac for 
your nearest Authorised Pacvac Service 
Agent.

Cause:

Blown fuse / tripped breaker.

Solution:

Reset circuit breaker or replace fuse.

PRoBLeM: Vacuum Cleaner has no/poor suction

Cause:

Dust bag full.

Solution:

Remove, empty and clean dust bag.

Cause:

Dust bag not installed correctly.

Solution:

Remove and empty dust bag making sure 
the rubber edging is correctly fitted around 
the canister.

Cause:

Hose not installed correctly.

Solution:

Reconnect hose and ensure correctly 
sealed.

Cause:

Blockages.

Solution:

Remove hose, wand  and floor tools; 
remove any blockages.

Cause:

Filters blocked.

Solution:

Clean filters.