Front Panel: 8KVA-10KVA

Rear Panel: 8KVA-10KVA

FIG 4

3

OUTPUT VOLTAGE 
METER

INPUT VOLTAGE 
METER

DELAYING INDICATOR

WORKING INDICATOR

UNUSUAL INDICATOR

DELAY / UNDELAY 
SELECTOR

POWER SWITCH

INPUT VOLTAGE 
TURBO SELECTOR

Microprocessor Control(CPU)

High & Low Voltage Protection 

SWR-10KVA

AUTOMATIC VOLTAGE REGULATOR

GND

Input

Output

Summary of Contents for SWR-1000VA

Page 1: ... VOLTAGE REGULATOR HIGH LOW VOLTAGE PROTECTION Instruction Manual Please read user manual carefully before use S WR 1 0 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltage Protection Output Voltage AUTOMATICVOLTAGEREGULATOR ...

Page 2: ... 1 Front Panel 300 500VA Rear Panel 300VA 500VA S WR 5 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltage Protection Output Voltage AUTOMATICVOLTAGEREGULATOR Fuse Input Output 1 OUTPUT VOLTAGE METER INPUT VOLTAGE METER DELAYING INDICATOR WORKING INDICATOR UNUSUAL INDICATOR DELAY UNDELAY SELECTOR POWER SWITCH NOTE Not equipped overheating Protection in standard configuration users sh...

Page 3: ...CATOR DELAY UNDELAY SELECTOR POWER SWITCH INPUT VOLTAGE TURBO SELECTOR Front Panel 1000VA 2000VA Rear Panel 1000VA 2000VA FIG 2 S WR 1 0 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltage Protection Output Voltage AUTOMATICVOLTAGEREGULATOR Fuse Input Output Front Panel 3000VA 5000VA Rear Panel 3000VA 5000VA FIG 3 Microprocessor Control CPU High Low Voltage Protection S WR 5 0 0 0 V ...

Page 4: ...LTAGE METER INPUT VOLTAGE METER DELAYING INDICATOR WORKING INDICATOR UNUSUAL INDICATOR DELAY UNDELAY SELECTOR POWER SWITCH INPUT VOLTAGE TURBO SELECTOR Microprocessor Control CPU High Low Voltage Protection S WR 1 0 KV A AUTOMATICVOLTAGEREGULATOR GND Input Output ...

Page 5: ...ive only after users notify manufacturer in advance WHEN OUTPUT VOLTAGE OF AVR IS HIGHER THAN SET VALUE THE SYSTEM ENTER INTO HIGH LOW VOLTAGE PROTECTION UNUSUAL RED LED FLASHES EVERY ONE SECOND AND OUTPUT GOES OFF WHEN OUTPUT VOLTAGE OF AVR IS UNDER SET VALUE THE SYSTEM ENTER NORMAL WORKING STATE UNUSUAL RED LED EXTINGUISHES WHEN TEMPERATURE OF AVR IS HIGHER THAN SET TEMPERATURE THE SYSTEM ENTER ...

Page 6: ...oltage and power of the appliance are accord with the labeled power and specification of the unit to avoid any damage Please connect the appliance before turning on the unit Switch on appliance after you make sure the unit is working normally with output voltage When connecting the electrical appliance with motor or compressor such as drill air conditioner and so on to the automatic voltage regula...

Page 7: ...sition delay time is 120 seconds When TURBO ON input voltage range is the rated input voltage labeled on the unit When TURBO OFF input voltage range is to be narrowed down 20V NOTE This turbo function only be effective for model 1000VA 1500VA 2000VA 30000VA 5000VA 8000VA 10000VA HOME MAIN SOCKET S WR 1 0 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltage Protection Output Voltage AU...

Page 8: ...lower or higher than labeled voltage AVR will turn into self protection state automatically the UNUSUAL RED indicator flashes every one second and output voltage will be cut off 7 THERMAL PROTECTION 8 OUTPUT CAPACITY The automatic voltage regulator will switch off automatically if the total wattage of the electrical appliances exceed the automatic voltage regulator output capacity 7 NOTE Not equip...

Page 9: ...he automatic voltage regulator and also to the earth terminal of the AC output socket The use of this terminal will depend on your particular installation In any installation heavy duty green insulated wire should be used for this connection WARNING BEFORE USING THIS AUTOMATIC VOLTAGE REGULATOR YOU MUST PROVIDE A GROUND CONNECTION TO THE AUTOMATIC VOLTAGE REGULATOR 8 FUSE Fuse Input Output ...

Page 10: ... neutral line is bonded to earth and there is normally no voltage between them In a stationary land based installation the earth terminal should be connected to a metal earthing stake driven into the ground to a depth of 1 2m or more 9 Model 3KVA 5KVA GROUND TERMINAL GND Output Input Output Model 8KVA 10KVA GROUND TERMINAL GND Input Output ...

Page 11: ...nnect all units C check the connected devices D use the unit again unless the problems concerning the connected devices have been solved When in use for a prolonged period of time the AC output may suddenly be cut off although the input voltage normal This may be caused by excessive temperatures If this happens Please proceed as follows A Switch off the automatic voltage regulator at once B Discon...

Page 12: ...of Protector For 12 EXPERT OF PROTECTOR FOR Make sure that the to tal laden power does not exceed the listed maximum output power of the regulator Be sure to connect the ground point to the ground for your safty ...

Page 13: ...z 10 Circuit Protection Circuit Protection 255V 250V AC T5 0A 5x20mm 2 9Kg 1000VA 1500VA 2000VA 250V AC T8 0A 250V AC T10A 250V AC T15A 4 7Kg 5 5Kg 6 7Kg 220V 230V 240V 110V 115V Thermal Protection O 130 C 5 NOTE Not equipped overheating Protection in standard configuration users should notify manufacturer and take special order if this function is required SWR 500VA SWR 1000VA SWR 1500VA SWR 2000...

Page 14: ...VA 220V 230V 240V 110V 115V SWR 3000VA SWR 5000VA SWR 8KVA SWR 10KVA 39x21 5x26cm 47x28x36 cm Yes Auto operation fan temperature or load 6 secs 120 secs Input Fuse Fuse Size Delay Time Dimension L x W x H Weight 16A 25A 40A 50A 16Kg 26Kg 31Kg Thermal Protection O 130 C 5 NOTE Not equipped overheating Protection in standard configuration users should notify manufacturer and take special order if th...

Page 15: ...put power of the regulator For color TV calculate it twice as its listed capacity Make sure that the regulator is of the same output voltage and frequency as the appliance s it connected Make sure that the voltage of electrical source is within the listed range of the input voltage of the regulator Always place the regulator in an environment that is A Well ventilated B Not exposed to direct sunli...