CAUTION:
PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO
PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.
WARNING:
Before installing or maintaining the luminary, make sure all powers are
TURNED OFF
.
Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and its not to exceed the maximum
ambient temperature rating noted on the specification sheet.
USHIBAYLxxxWPL Series LED Highbays Installation Guide
Step 2-
Slide out the default lens.
Step 1-
Using a Phillips Screw Driver, remove the two screws from the side of the
!
luminaire. After the two screws have been removed, place them down
!
somewhere
safe and remove the Side Angle from the fixture in order to access the default
lens. It is important to not lose these screws because they will be used
to fasten the luminaire back together once the new Clear Lens has been installed.
Clear Lens
PART NO.
IMAGE
DESCRIPTION
QTY
AC-LHA-CL2S
Clear Lens for
USHIBAYL90WPL
USHIBAYL110WPL
1
AC-LHA-CL2L
Clear Lens for
USHIBAYL162WPL
1
AC-LHA-CL4S
Clear Lens for
USHIBAYL178WPL
USHIBAYL223WPL
1
AC-LHA-CL4L
Clear Lens for
USHIBAYL321WPL
1
Step 3-
Slide in the New Clear lens.
Step 4-
Once the new lens has been
installed, place the side angle back into
place and fasten it back using the same
screws used in Step 1.
Step 5-
Remove the cover plate in
order to access wires required for
installation. Have an AC Power
Supply Conduit with a J-Box
attacked to the ceiling come down
to approximately the same height
of the chains. Use the Wiring
Diagram provided above to
properly wire the luminaire to the
power supply. All wiring
connections must be made either
inside a Junction Box or the back
housing of the luminaire.