FHZL THREADED PIPE MOUNTING & CONDUIT INSTALLATION

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE.  RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

PacLights fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes.  Proper grounding is required for safety.  
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR 
WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNINGS:
• 

MIN 90°C SUPPLY CONDUCTOR.  THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE 
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE 
HAZARDS INVOLVED.

• 

Make certain power is OFF before installing or maintaining fi xture.  No user serviceable parts inside.

• 

To prevent wiring damage or abrasion, do not expose wiring to edges of sharp objects.

CAUTION:
• 

For  proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened fi rmly.  Apply weatherproof silicone 
sealant around the edge of the Back Box and/or Junction Box.  This is especially important with an uneven wall surface.  Silicone all plugs and 
unused conduit entries.

FIG. 1

 

   

 

FHZL 040 

                    

 

 

FHZL 080/120

The FHZL Threaded Pipe Mount is installed from the top and the Conduit from the side of the fi xture with the wiring.  The FHZL Series Wiring requires 
the Driver Box Cover to be removed.  Remove the 3/4” NPT Nut (side or top of fi xture), the Screw Cap Covers and loosen the Screws (Fig. 1).  Open the 
Driver Box Cover and the Lanyard will hold the Cover to prevent it from falling off .  Pull the Wiring (Aluminum or Copper conductors) through one of the 
theaded holes and connect to the Terminal Block (Fig. 2 or 3).  Re-install the Driver Box Cover, Pipe at the top or Conduit at the side (Both Not Included) 
in place of the 3/4” NPT Nut (

Use silicone gel around the threads for water tight seal

), Screws, and Screw Caps in the reverse order.  For top installation, 

tighten the fi xing Screw to the Pipe (Fig. 2).          

Connect the ACL and the ACN from the FHZL Fixture to the conduit with the AC power Supply Cable.  Follow the Wiring Diagram provided.

AC POWER SUPPLY

FHZL DRIVER

GRA

Y (-)

PURPLE (+)

HOT [BLACK]

NEUTRAL [WHITE]

GROUND [GREEN]

WIRING DIAGRAM

DIM

INPUT

SCREWS

SCREW 
CAPS

FIG. 2

LANYARD

3/4” NPT 
NUTS

TERMINAL 
BLOCK

WIRING

DRIVER BOX 
COVER

CONDUIT

PIPE

TERMINAL 
BLOCK

WIRING

FIG. 3 

SCREW

LANYARD

Summary of Contents for FHZL Series

Page 1: ...e seated properly and all screws inserted and tightened firmly Apply weatherproof silicone sealant around the edge of the Back Box and or Junction Box This is especially important with an uneven wall surface Silicone all plugs and unused conduit entries FIG 1 FHZL 040 FHZL 080 120 The FHZL Threaded Pipe Mount is installed from the top and the Conduit from the side of the fixture with the wiring The ...

Page 2: ...ed at a fixed position the FHZL fixture can be adjusted by loosening the large Screws and removing the smaller Screws at the sides of the of the Trunnion Mount This allows the fixture to rotate to the desired tilt angle 30 60 90 degrees to aim at a specific position Fig 7 4 FIG 7 Fasten the Trunnion Mount to the mounting surface Wall or Ceiling with the appropriate bolts may vary depending on the moun...

Page 3: ...he appropriate bolts may vary depending on the mounting surface by a certified personnel Fig 11 Refer to 2 for dimensions FIG 12 Instead of having the fixture directly surface mounted at a fixed position the FHZL fixture can be adjusted by loosening the large Screws and removing the smaller Screws at the sides of the of the Surface Mount This allows the fixture to rotate to the desired tilt angle to ai...

Page 4: ...NT NUTS U BOLT Slide the FHZL fixture with the U Bolts and Nuts partially fastened onto the Round Pole Fig 15 2 Tighten the nuts to the U Bolts and tighten the Wing Nut Screw from the bottom of the Trunnion Mount to secure the Pole Fig 16 3 FIG 15 POLE WING NUT SCREW FIG 16 FHZL CHAIN MOUNT OPTIONAL The Optional Chain Mount can be used for all the FHZL fixtures The Chain Mount includes the two Chain...

Page 5: ...WS WIRE GUARD FHZL SAFETY RETENTION CABLE 1 The FHZL Safety Retention Cable is necessary for the all FHZL fixtures Fig 21 FIG 19 The Wire Guard s should be placed on the fixture Cover prior to the FHZL fixture installation Install the Screws to hold the Wire Guard s in place for each fixture Cover Fig 20 2 FIG 21 FIG 22 2 Attach the Safety Retention Cable to the FHZL fixture as shown below Fig 22 There...