background image

CAUTION:

PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO

PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.

Before installing or maintaining the luminary, make sure all power is

WARNING:

.

TURNED OFF

Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and it is not to exceed the
maximum ambient temperature rating noted on the specification sheet.

FALC Series LED Area Light

Installation Guide

Need help? Tech help line:

(800) 988-6386

Email:

[email protected]

Website:

www.paclights.com

Copyright © 2020 PacLights

All Rights Reserved

Note: Instructions are subject to change at any time without notice

FALC200, FALC240, FALC300          FALC080, FALC100, FALC150

02-00041-20423

Page 1 of 7

Connect the ACL and the ACN from the FALC Fixture to the conduit with the AC Power Supply Cable.  Follow the Wiring Diagram provided.

AC Power Supply

GROUND [GREEN]

NEUTRAL [WHITE]

HOT [BLACK]

INPUT

FALC FIXTURE

FALC Initial Set-Up

Set the Short-Cap on the NEMA
Receptacle correctly.  Install the
Short-Cap provided by pressing down
and twisting CW.

Note: If Photocell Sensor  is

provided see the following for
instructions.

The default settings can be changed by adjusting the DIP Switches on the Motion

Sensor.  Please refer to the table on this page and also directly on the Motion Sensor.

Turn over the FALC Fixture showing the Lens side.  Remove the Screws (4) from

the Shell Cover. Then remove the Shell Cover from the FALC Fixture. The Motion
Sensor is now open to adjust (if needed) the setting. The process is the same for all
FALC-LV-MS fixtures.

Optional

Microwave Motion Sensor(FALC-LV-MS ONLY)

1

2

The Integrated Microwave Motion Sensor is a programmable motion detector. This is
only for the FALC-LV-MS models ONLY. The default factory settings are as follows:
Detection Area=100%, Hold Time=5 sec, Stand-By Period=5 sec, Stand-By Dimming
Level=10%, and Daylight (Photo) Sensor=Disable.

Note: If the Microwave Motion Sensor is not included or adjustment is not needed,

the following steps can be skipped.

MOTION
SENSOR

DIP

SWITCHES

FALC-LV
SHELL
COVER

SCREWS

Microwave Motion Sensor DIP Pin Setting

Detection Area

Detection area having motion and not enough ambient light will
activate the sensor. The sensor can be set at 100%, 75%, 50%,
or 10%.

Hold Time

Hold Time refers to the time period the fixture remains at 100%
illumination after motion is detected.  Hold Time can range from
5s to 20 minutes. The fixture will remain at full illumination until
‘Hold Time’ ends, then reducing to Stand-By Dimming Level.

Stand-By Period

The Stand-By period begins when the ‘Hold Time’ ends. The
fixture remains at a Stand-By Dimming Level before it completely
switches off while motion is not present.  When set to “+∞” mode,
the low led light is held until motion is detected.

Daylight (Photo) Sensor

The Daylight Sensor, measured in LUX can be set to allow the
fixture to illuminate below a surrounding minimum ambient
brightness threshold. The sensor can be set from 2 to 100 LUX.
When set to Disable mode, the Daylight Sensor will switch on
the fixture when motion is detected regardless of ambient light.

Stand-By Dimming Level

Stand-By Dimming Level is when ‘Hold Time’ has ended, there
is no movement in the area and the light output is reduced. The
Stand-By Dimming Level can be set at 50%, 30%, 20%, or 10%.

By selecting the combination on the DIP switches, sensor data can be precisely
set for each specific application as seen below.

+∞

+∞

SHORT-CAP

NEMA

RECEPTACLE

Turn over the FALC Fixture showing the Fin side. All FALC Fixtures

come with a NEMA Seven-Prong Twist Lock receptacle (Compatible with
Three-Prong Photocell Sensors) with Short-Cap to be installed.  Remove
the Short-Cap by twisting CCW and lifting.

Optional

Photocell Sensor

The Photocell Sensor has a Dusk to Dawn functionality. The Photocell Sensor can be easily field installed on all FALC fixtures as
shown below.  Note: If the Photocell Sensor is not included the following steps can be skipped.  If the Photocell Sensor is included
prior to field installation, Step 1 can be skipped.

1

Place the Photocell Sensor on the NEMA

receptacle.  Push down and twist CW. The
process is the same for all FALC Fixtures.

2

PHOTOCELL

SENSOR

NEMA

RECEPTACLE

NEMA THREE-PRONG

TWIST LOCK PLUG

SHORT-

CAP

Initial Set-up and Optional Controls

2

9

“Initial Set-up and Optional Controls”

Summary of Contents for FALC Series

Page 1: ... Motion Sensor is not included or adjustment is not needed the following steps can be skipped MOTION SENSOR DIP SWITCHES FALC LV SHELL COVER SCREWS Microwave Motion Sensor DIP Pin Setting Detection Area Detection area having motion and not enough ambient light will activate the sensor The sensor can be set at 100 75 50 or 10 Hold Time Hold Time refers to the time period the fixture remains at 100 i...

Page 2: ...ALC SF SLIPFITTER 7 8 Move the FALC FIXTURE to the desired tilt angle Mate the teeth of the FALC BRACKET MOUNT and the SLIPFITTER together Tighten the Socket Head Screw with a wrench SLIPFITTER SCREW FALC FIXTURE AC ALC SF Slipfitter Mount AC ALC SF Slipfitter Mount FALC Series LED Area Light Installation Guide Need help Tech help line 800 988 6386 Email cs paclights com Website www paclights com Co...

Page 3: ...nt Follow the Wiring Diagram to properly connect the FALC Fixture For the Round Pole repeat Steps1 6 the same as a Square Pole except the round pole gasket will still be attached to the ARM MOUNT All wiring must be installed by a certified electrician and must be compliant to NEC standards Once all wiring is properly installed fasten the SIDE PLATE back to the Arm Mount Page 3 of 7 SOCKET HEAD SCRE...

Page 4: ... desired tilt angle and fasten the Socket Head Screw Align the teeth from the FALC Bracket Mount to the Trunnion Mount Use the Socket Head Screw to fasten them together You can connect the FALC CABLE to the Power Supply without using a Junction Box only if used with a weather proof connector Page 4 of 7 BOLTS TRUNNION MOUNT SOCKET HEAD SCREW 2 POWER SUPPLY CABLE 3 5 If the Power Supply Cable is ra...

Page 5: ...Rights Reserved STANDARD INSTALLATION STEPS 02 00041 20423 Note Instructions are subject to change at any time without notice Run the FALC CABLE through the Universal Mount and align the teeth from the FALC Bracket Mount with the teeth on the Universal Mount FALC CABLE FALC FIXTURE FALC BRACKET MOUNT UNIVERSAL MOUNT UNIVERSAL MOUNT FALC CABLE FALC BRACKET MOUNT FALC FIXTURE SCREW UNIVERSAL MOUNT F...

Page 6: ...le through the inside of the Arm Mount Align the hole and teeth from the Arm Mount with the FALC Bracket Mount and use the Socket Head Screw to fasten them together at the desired FALC Fixture tilt angle Place the Locking Plate and Gasket inside the Mounting Pole Run the Power Supply Cable through the 0 48 clearance Slot and fasten the FALC Fixture onto the Mounting Pole with the Socket Head Screw...

Page 7: ... be compliant to NEC standards Page 7 of 7 SIDE PLATE SIDE PLATE GASKET SCREWS DRILLING TEMPLATE Run Power Supply Cable through this slot opening into the Arm Mount Ø 0 375 Clearance holes on pole to align with Locking Plate hole locations 5 5 6 25 0 75 0 77 R 24 Remove the 4 Flat Head Machine Screws and the Side Plate before installing onto the FALC Fixture If the Power Supply Cable is coming fro...

Reviews: